Desa VYGF33NRA, VYGF33PRA Installing GAS Piping to Fireplace Location, Installation Items Needed

Page 12

12

INSTALLATION

Built-In Installation Fireplace Installation (Cont.) Installing Gas Piping to Fireplace Location

INSTALLATION

Continued

Mantel Clearances for Built-In Installation

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

NOTICE: If your installation does not meet the mini- mum clearances shown, you must do one of the following:

raise the mantel to an acceptable height

remove the mantel

NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

INSTALLING GAS PIPING TO FIREPLACE LOCATION

WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pres- sure regulator.

WARNING: A qualified service person must con- nect fireplace to gas supply. Follow all local codes.

CAUTION: Never connect propane/LP fireplace directly to the propane/LP supply. This fireplace requires an external regulator (not supplied). Install the external regulator between the fireplace and pro- pane/LP supply.

Wall board or facing material (above firebox) may be of

Mantel Shelf

WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

combustible material, including decorative mantel ornaments or other similar projec- tions off of the facing material.

Framing

Material

Firebox

Wire-mesh

Screen

10"

8"

6"

21/2"

Noncombustible Material May Project Off this Surface above the Firebox Hood

Supplied Firebox

Hood Must Be

Used at All Times

13" 16" 19" 21"

Note: All vertical measurements are from top of fireplace hood opening to bottom of mantel shelf.

These minimum clearances replace any other recommended clearances supplied with your ANSI Z21.11.2 approved gas logs.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator for propane/LP unit only (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap (optional)

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by lo- cal codes) (not provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, pages 34 and 35.

Figure 20 - Minimum Mantel Clearances for Built-In Installation

For propane/LP units, the installer must supply an external regula- tor. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent point- ing down as shown in Figure 21, page 13. Pointing the vent down protects it from freezing rain or sleet.

For..com

105270

Image 12
Contents Qqqq ¢¢¢¢ What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Other gasesProduct Features Local CodesUnpacking AIR for Combustion and VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installing HoodCheck GAS Type Electrical HookupInstallation Clearances Conventional Fireplace InstallationIncluded with Mantel Accessory Assembling and Attaching Optional Brass TrimPlacing Hearth Base Accessory Against Wall Actual Framing Height Front Width 34 5 35 1 Depth 16 11 17 3 Support Bracket Firebox Wrapper Shield Power Screws Cord Installing GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Connecting Fireplace to GAS Supply Gas ConnectionPressure Testing gas Supply Piping system Checking GAS ConnectionsInstalling Logs Pressure Testing Fireplace Gas ConnectionsFPVF33PR Optional Wireless HAND-HELD Remote Installing 9-VOLT BatteriesInstalling Remote Receiver Unit Installing 9-Volt Battery in ReceiverFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions Manual Lighting Procedure To Turn OFF GAS to ApplianceOptional Remote Operation Inspecting Burners Optional Blower OperationPilot Flame Pattern Ghrc Series OperationCleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleBurner Primary AIR Holes Main BurnerWiring Diagram SpecificationsLogs Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Illustrated Parts Breakdown VYGF33PRAParts List KEY Part Number VYGF33PRA VYGF33NRA Description QTYFirebox VYGF33PRA VYGF33NRA Firebox VYGF33PRA & VYGF33NRA KEY Part Number Description QTYFPVF33PR KEY Part Number FPVF33PR FPVF33NR Description QTY Firebox FPVF33PR FPVF33NR Firebox FPVF33PR & FPVF33NR Accessories Receiver and HAND-HELD Remote Control KIT Ghrc Series WALL-MOUNT Thermostat Switch GWMT1WALL-MOUNT ON/OFF Switch GWMS2 Firebox Perimeter Brass Trim Accessory GA6090Replacement Parts Technical ServiceService Hints Parts Under WarrantyOwners Registration Form Postage Required 105270 Warranty Information

FPVF33NR, VYGF33NRA, VYGF33PRA specifications

Desa VYGF33PRA, VYGF33NRA, and FPVF33NR are innovative heating solutions designed to provide efficient and effective warmth for residential and commercial spaces. These models stand out due to their advanced features, modern technologies, and reliable characteristics.

The VYGF33PRA and VYGF33NRA variants are characterized by their versatile design, allowing them to seamlessly fit into a variety of settings. They are equipped with high-efficiency heating elements that ensure optimal heat distribution. These models utilize advanced heat exchanger technology, which not only improves efficiency but also minimizes energy consumption. This makes them an eco-friendly choice for those looking to reduce their carbon footprint without sacrificing comfort.

Safety is a top priority with these models, featuring built-in safety mechanisms like overheat protection, tip-over switches, and thermal cut-off features. This ensures that users have peace of mind while operating the units, particularly in child- or pet-friendly environments. Additionally, the user-friendly interface, complete with intuitive controls, allows for easy setting adjustments and temperature monitoring.

The FPVF33NR model also showcases remarkable features that appeal to modern consumers. It incorporates advanced digital technology, allowing for programmable settings and remote control capabilities. Users can easily adjust heating schedules, enhancing convenience and efficiency.

The energy efficiency rating is another highlight of these models. With features like smart thermostats and energy-saving modes, they are designed to minimize energy usage without compromising on performance. This not only helps in reducing utility bills but also aligns with sustainable living practices.

Moreover, these heaters are built to last, featuring durable materials that ensure longevity and reliability. The aesthetic design is appealing, allowing them to complement any interior décor effortlessly.

In conclusion, Desa VYGF33PRA, VYGF33NRA, and FPVF33NR deliver superior heating performance, user-friendly technology, and thoughtful safety features. Their combination of efficiency, durability, and modern design makes them an excellent choice for anyone in need of dependable heating solutions. Investing in these models will not only enhance comfort but also contribute to a more sustainable energy future.