SAFETY INFORMATION

WARNING:Thisproductcon- tainsand/orgenerateschemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, elec- trical shock, and carbon mon- oxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of car- bon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural and Propane/LP Gas: Natural and propane/ LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warn- ings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approvedforusewiththisheater.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

Due to high temperatures, the appliance should be located out of traffic and away from furni- ture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Fireplace front and screen be- come very hot when running fire- place. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fire- place will remain hot for a time after shutdown. Allow surfaces to cool before touching.

Carefully supervise young chil- dren when they are in the room with fireplace. When using the optional hand-held remote ac- cessory, keep selector switch in the OFF position to prevent chil- dren from turning on burners with remote.

You must operate this fireplace with the fireplace screen and hood in place. Make sure fire- place screen and hood are in place before running heater.

Keep the appliance area clear and free from combustible ma- terials, gasoline, and other flam- mable vapors and liquids.

113132-01A

www.desatech.com

3

Image 3
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Identification Log Base Assembly VSGF33NRB ShownAIR for Combustion Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Electrical Hookup InstallationInstalling Hood Check GAS TypeTop Installation ClearancesAccess Hole Conventional Fireplace InstallationDepth BUILT-IN Fireplace InstallationActual Framing Height Front WidthInstalling GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Gas Connection Propane/LPHex socket wrench or nut-driver Phillips screwdriver Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Damage or personal injury Instructions For Your Safety Read Before LightingOperating Fireplace LightingShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional HAND-HELD Remote OperationThermostat Model Ghrctb ON/OFF Model GhrcbMain Burner Inspecting BurnersOptional Blower Operation Pilot Flame PatternBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceWiring Diagram SpecificationsLogs Observed Problem Possible Cause Remedy TroubleshootingDiagram, Ventilation requirements Gas leak. See Warning Statement onGas leak. See Warning statement on Parts Under Warranty Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Parts List Fireplace Models EFS33NRB, VSGF33NRB, EFS33PRB and VSGF33PRB Parts Available not Shown Accessories Laminate Trim for Hearth or Mantel Cabinet Mantel and Full Hearth BaseReceiver and HAND-HELD Thermostat Remote Control KIT Ghrctb Receiver and HAND-HELD Remote Control KIT GhrcbFirebox Brick Liner G8005 113132-01A Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace

VSGF33PRB, EFS33PRB, VSGF33NRB, EFS33NRB specifications

Desa EFS33PRB, VSGF33PRB, EFS33NRB, and VSGF33NRB are four highly regarded heating appliances known for their efficient performance and user-friendly features. Each of these models offers a unique set of characteristics, making them suitable for different heating needs and preferences.

The Desa EFS33PRB is a prominent model designed with energy efficiency in mind. It utilizes advanced combustion technology that maximizes heat output while reducing fuel consumption. This model features a sleek, modern design complemented by a user-friendly control panel. The adjustable thermostat allows users to set their desired temperature easily, ensuring comfort throughout the space. Additionally, the EFS33PRB is equipped with an automatic shut-off mechanism for enhanced safety, providing peace of mind during usage.

On the other hand, the VSGF33PRB stands out with its high-velocity fan that ensures rapid and even heat distribution across larger areas. This model features a robust build quality and is designed to operate quietly, making it an excellent option for residential spaces where noise levels must be kept to a minimum. The VSGF33PRB also incorporates a range of settings for different heating needs, allowing users to customize their heating experience.

Moving to the EFS33NRB model, it emphasizes versatility with its multi-fuel capability. This appliance can efficiently utilize various fuel types, making it suitable for different environments and preferences. The EFS33NRB is designed with user convenience in mind, featuring easy maintenance capabilities, such as a removable ash pan for hassle-free cleaning. It also includes an electronic ignition system, ensuring quick and reliable startup every time.

Lastly, the VSGF33NRB shares many characteristics with its counterparts but enhances its appeal with an increased focus on eco-friendliness. This model is crafted to produce lower emissions, contributing positively to environmental sustainability. It boasts a high-efficiency rating, thus not only providing effective heating solutions but also reducing energy bills.

In summary, the Desa EFS33PRB, VSGF33PRB, EFS33NRB, and VSGF33NRB collectively represent a complete range of heating options suitable for various applications. Their dedication to efficiency, safety, and user convenience makes them desirable choices for consumers seeking reliable and innovative heating solutions. Whether it be through advanced technology, enhanced safety features, or eco-friendly capabilities, these models stand out in the competitive market of heating appliances.