Desa VSGF33NRB, EFS33NRB Checking GAS Connections, Pressure Testing Gas Supply Piping System

Page 15

INSTALLATION

Continued

CHECKING GAS CONNECTIONS

WARNING: Test all gas pip- ing and connections, internal and external to unit, for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve lo- cated on or near gas meter for natural gas, or using compressed air.

3.Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP sup- ply to equipment shutoff valve for propane/LP (see Figures 22 and 23). Apply noncorrosive leak detection fluid to all joints. Bubbles form- ing show a leak.

4.Correct all leaks at once.

open flame to check for a leak. Apply a noncorrosive leak de- tection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Equipment Shutoff Valve

Open

Closed

CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and fireplace. See guidelines under Connecting Fireplace to Gas Supply, page 14.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect fireplace with its main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage fireplace regulator.

2.Cap off open end of gas pipe where equip- ment shutoff valve was connected.

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve lo- cated on or near gas meter for natural gas, or using compressed air.

4.Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect fireplace and equipment shutoff valve to gas supply. Check reconnected fit- tings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 21).

Figure 21 - Equipment Shutoff Valve

Equipment Shutoff Valve

Gas Meter

Gas Control Valve

Figure 22 - Checking Gas Joints for

Natural Gas

Equipment Shutoff Valve

Propane/LP

Supply Tank

Gas Control Valve

Figure 23 - Checking Gas Joints for

Propane/LP Gas

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 21).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP sup- ply tank valve.

113132-01A

www.desatech.com

15

Image 15
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Identification Log Base Assembly VSGF33NRB ShownAIR for Combustion Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Electrical Hookup InstallationInstalling Hood Check GAS TypeTop Installation ClearancesAccess Hole Conventional Fireplace InstallationDepth BUILT-IN Fireplace InstallationActual Framing Height Front WidthInstalling GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Gas Connection Propane/LPHex socket wrench or nut-driver Phillips screwdriver Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Damage or personal injury Instructions For Your Safety Read Before LightingOperating Fireplace LightingShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional HAND-HELD Remote OperationThermostat Model Ghrctb ON/OFF Model GhrcbMain Burner Inspecting BurnersOptional Blower Operation Pilot Flame PatternBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceWiring Diagram SpecificationsLogs Observed Problem Possible Cause Remedy TroubleshootingDiagram, Ventilation requirements Gas leak. See Warning Statement onGas leak. See Warning statement on Parts Under Warranty Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Parts List Fireplace Models EFS33NRB, VSGF33NRB, EFS33PRB and VSGF33PRB Parts Available not Shown Accessories Laminate Trim for Hearth or Mantel Cabinet Mantel and Full Hearth BaseReceiver and HAND-HELD Thermostat Remote Control KIT Ghrctb Receiver and HAND-HELD Remote Control KIT GhrcbFirebox Brick Liner G8005 113132-01A Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace

VSGF33PRB, EFS33PRB, VSGF33NRB, EFS33NRB specifications

Desa EFS33PRB, VSGF33PRB, EFS33NRB, and VSGF33NRB are four highly regarded heating appliances known for their efficient performance and user-friendly features. Each of these models offers a unique set of characteristics, making them suitable for different heating needs and preferences.

The Desa EFS33PRB is a prominent model designed with energy efficiency in mind. It utilizes advanced combustion technology that maximizes heat output while reducing fuel consumption. This model features a sleek, modern design complemented by a user-friendly control panel. The adjustable thermostat allows users to set their desired temperature easily, ensuring comfort throughout the space. Additionally, the EFS33PRB is equipped with an automatic shut-off mechanism for enhanced safety, providing peace of mind during usage.

On the other hand, the VSGF33PRB stands out with its high-velocity fan that ensures rapid and even heat distribution across larger areas. This model features a robust build quality and is designed to operate quietly, making it an excellent option for residential spaces where noise levels must be kept to a minimum. The VSGF33PRB also incorporates a range of settings for different heating needs, allowing users to customize their heating experience.

Moving to the EFS33NRB model, it emphasizes versatility with its multi-fuel capability. This appliance can efficiently utilize various fuel types, making it suitable for different environments and preferences. The EFS33NRB is designed with user convenience in mind, featuring easy maintenance capabilities, such as a removable ash pan for hassle-free cleaning. It also includes an electronic ignition system, ensuring quick and reliable startup every time.

Lastly, the VSGF33NRB shares many characteristics with its counterparts but enhances its appeal with an increased focus on eco-friendliness. This model is crafted to produce lower emissions, contributing positively to environmental sustainability. It boasts a high-efficiency rating, thus not only providing effective heating solutions but also reducing energy bills.

In summary, the Desa EFS33PRB, VSGF33PRB, EFS33NRB, and VSGF33NRB collectively represent a complete range of heating options suitable for various applications. Their dedication to efficiency, safety, and user convenience makes them desirable choices for consumers seeking reliable and innovative heating solutions. Whether it be through advanced technology, enhanced safety features, or eco-friendly capabilities, these models stand out in the competitive market of heating appliances.