Desa EFS33NRB, EFS33PRB, VSGF33PRB Product Identification, Log Base Assembly VSGF33NRB Shown

Page 4

SAFETY INFORMATION

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This appli- ance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) in- side any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bed- room or bathroom.

5.Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, pages 21 and 22.

8.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

9.This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if enough fresh air is not available. See Air for Combustion and Ventilation, pages 5 through 7. If fireplace keeps shutting off, see Troubleshooting, pages 23 through 26.

10.Do not run fireplace

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not use this fireplace to cook food or burn paper or other objects.

12.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

13.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

14.Turn fireplace off and let cool before servic- ing. Only a qualified service person should service and repair fireplace.

15.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

16.To prevent performance problems in pro- pane/LP units, do not use propane/LP fuel tanks of less than 100 lbs. capacity (pro- pane/LP units only).

17.Provide adequate clearances around air openings.

PRODUCT

IDENTIFICATION

Rear Log

 

Middle Log

Rear

Front

Burner

Log

 

Piezo

 

Ignitor

 

Front

 

Burner

 

Optional

 

Remote Control

Base Assembly

Figure 1 - Log Base Assembly

(VSGF33NRB Shown)

Top Outer Casing

Fireplace

Top Louver

Hood

Assembly

 

Firebox

 

Support

Optional

 

Blower

 

Assembly

 

(Not

 

Included)

 

Bottom

Screen

Louver

Assembly

Assembly

Figure 2 - Fireplace (VSGF33NRB Shown)

4

www.desatech.com

113132-01A

Image 4
Contents What to do if YOU Smell GAS Table of Contents Safety Information Log Base Assembly VSGF33NRB Shown Product IdentificationProduct Features Local CodesUnpacking AIR for Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Fireplace LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installing HoodCheck GAS Type Electrical HookupInstallation Clearances TopConventional Fireplace Installation Access HoleBUILT-IN Fireplace Installation Actual Framing HeightFront Width DepthMantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Propane/LP Gas ConnectionConnecting Fireplace to GAS Supply Hex socket wrench or nut-driver Phillips screwdriverPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Damage or personal injury For Your Safety Read Before Lighting Operating FireplaceLighting InstructionsManual Lighting Procedure To Turn OFF GAS To ApplianceOptional HAND-HELD Remote Operation Shutting Off HeaterON/OFF Model Ghrcb Thermostat Model GhrctbInspecting Burners Optional Blower OperationPilot Flame Pattern Main BurnerCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleSpecifications Wiring DiagramLogs Troubleshooting Observed Problem Possible Cause RemedyDiagram, Ventilation requirements Statement on Gas leak. See WarningGas leak. See Warning statement on Replacement Parts Service HintsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Parts List Fireplace Models EFS33NRB, VSGF33NRB, EFS33PRB and VSGF33PRB Parts Available not Shown Accessories Cabinet Mantel and Full Hearth Base Laminate Trim for Hearth or MantelReceiver and HAND-HELD Remote Control KIT Ghrcb Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbFirebox Brick Liner G8005 113132-01A Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace

VSGF33PRB, EFS33PRB, VSGF33NRB, EFS33NRB specifications

Desa EFS33PRB, VSGF33PRB, EFS33NRB, and VSGF33NRB are four highly regarded heating appliances known for their efficient performance and user-friendly features. Each of these models offers a unique set of characteristics, making them suitable for different heating needs and preferences.

The Desa EFS33PRB is a prominent model designed with energy efficiency in mind. It utilizes advanced combustion technology that maximizes heat output while reducing fuel consumption. This model features a sleek, modern design complemented by a user-friendly control panel. The adjustable thermostat allows users to set their desired temperature easily, ensuring comfort throughout the space. Additionally, the EFS33PRB is equipped with an automatic shut-off mechanism for enhanced safety, providing peace of mind during usage.

On the other hand, the VSGF33PRB stands out with its high-velocity fan that ensures rapid and even heat distribution across larger areas. This model features a robust build quality and is designed to operate quietly, making it an excellent option for residential spaces where noise levels must be kept to a minimum. The VSGF33PRB also incorporates a range of settings for different heating needs, allowing users to customize their heating experience.

Moving to the EFS33NRB model, it emphasizes versatility with its multi-fuel capability. This appliance can efficiently utilize various fuel types, making it suitable for different environments and preferences. The EFS33NRB is designed with user convenience in mind, featuring easy maintenance capabilities, such as a removable ash pan for hassle-free cleaning. It also includes an electronic ignition system, ensuring quick and reliable startup every time.

Lastly, the VSGF33NRB shares many characteristics with its counterparts but enhances its appeal with an increased focus on eco-friendliness. This model is crafted to produce lower emissions, contributing positively to environmental sustainability. It boasts a high-efficiency rating, thus not only providing effective heating solutions but also reducing energy bills.

In summary, the Desa EFS33PRB, VSGF33PRB, EFS33NRB, and VSGF33NRB collectively represent a complete range of heating options suitable for various applications. Their dedication to efficiency, safety, and user convenience makes them desirable choices for consumers seeking reliable and innovative heating solutions. Whether it be through advanced technology, enhanced safety features, or eco-friendly capabilities, these models stand out in the competitive market of heating appliances.