Desa FMH26TN 14 installation manual Troubleshooting, Observed Problem, Possible Cause, Remedy

Page 20
TROUBLESHOOTING

NATURAL GAS VENT-FREE FIREPLACE SYSTEM

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM WARNING: Turn off and un- plug fireplace and let cool before servicing. Only a qualified ser- vice person should service and repair fireplace.

POSSIBLE CAUSE CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no

1.

Ignitor cable pinched or wet

1.

Free ignitor cable if pinched by any

spark at ODS/pilot

 

 

 

metal or tubing. Keep ignitor cable dry

 

2.

Ignitor electrode not connected to igni-

2.

Reconnect ignitor cable

 

 

tor cable

 

 

 

3.

Broken ignitor cable

3.

Replace ignitor cable

 

4.

Bad piezo ignitor

4.

Replace piezo ignitor

 

5.

Ignitor electrode broken

5.

Replace piezo ignitor

 

6.

Ignitor electrode positioned wrong

6.

Replace piezo ignitor

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

spark at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob. Re-

 

 

 

 

peat igniting operation until air is removed

 

5.

ODS/pilot is clogged

5.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 19) or replace ODS/

 

 

 

 

pilot assembly

 

6.

Gas regulator setting is not correct

6.

Replace gas regulator

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

knob pressed in 30 seconds

 

3.

Safety interlock system has been triggered

3.

Wait one minute for safety interlock sys-

 

 

 

 

tem to reset. Repeat ignition operation

 

4.

Equipment shutoff valve not fully open

4.

Fully open equipment shutoff valve

 

5.

Thermocouple connection loose at con-

5.

Hand tighten until snug, then tighten 1/4

 

 

trol valve

 

turn more

 

6.

Pilot flame not touching thermocouple,

6.

A) Contact local natural gas company

 

 

which allows thermocouple to cool,

 

 

 

 

causing pilot flame to go out. This prob-

 

B) Clean ODS/pilot (see Cleaning and

 

 

lem could be caused by one or both of

 

Maintenance, page 19) or replace ODS/

 

 

the following:

 

pilot assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

7.

Thermocouple damaged

7.

Replace thermocouple

 

8.

Control valve damaged

8.

Replace control valve

www.desatech.com

20

107105

Image 20
Contents VENT-FREENATURAL GAS FIREPLACE SYSTEM WHAT TO DO IF YOU SMELL GASDo not try to light any appliance OWNER’S OPERATION AND INSTALLATION MANUALWARNINGS SAFETY INFORMATIONNATURAL GAS VENT-FREEFIREPLACE SYSTEM PRODUCT FEATURES SAFETY PILOTLOCAL CODES UNPACKINGASSEMBLY Installing Logcessories, page 26. Install optional blower now. Follow installation inAIR FOR COMBUSTION AND VENTILATION PROVIDING ADEQUATE VENTILATIONUnusually Tight Construction Confined and Unconfined SpaceDETERMINING FRESH-AIRFLOW FOR FIREPLACE LOCATION NATURAL GAS VENT-FREEFIREPLACE SYSTEMAIR FOR COMBUSTION AND VENTILATION ContinuedVENTILATION AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors AIR FOR COMBUSTION AND VENTILATIONINSTALLATION INSTALLATION ITEMSCHECK GAS TYPE LOCATING FIREPLACEContinued BUILT-INFIREPLACE INSTALLATIONINSTALLATION OPTIONAL MANTEL INSTALLATION Mantel Clearances for Built-InInstallationINSTALLATION NATURAL GAS VENT-FREEFIREPLACE SYSTEMINSTALLING BLOWER ACCESSORY GA3450T Removing Upper Louver AssemblyInstalling Blower Assembly Removing Valve Cover ShieldINSTALLATION 9. Install the switch plate on the valveNATURAL GAS VENT-FREEFIREPLACE SYSTEM ContinuedContinued For Built-InInstallationINSTALLATION CONNECTING TO GAS SUPPLY Extension CordAttaching Wood Base to Solid Floor INSTALLATIONContinued Installation Items NeededINSTALLATION Pressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsCHECKING GAS CONNECTIONS INSTALLATIONLIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING FIREPLACE MANUAL LIGHTING PROCEDURE INSPECTING BURNERTO TURN OFF GAS TO APPLIANCE THERMOSTAT CONTROL OPERATIONCLEANING AND MAINTENANCE BURNER FLAME PATTERNCABINET Air PassagewaysTROUBLESHOOTING OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYMaintenance, page TROUBLESHOOTINGOBSERVED PROBLEM Continueding Gas Connections, page 1. Refer to Air for Combustion and VentiTROUBLESHOOTING OBSERVED PROBLEMSPECIFICATIONS REPLACEMENT PARTSSERVICE HINTS TECHNICAL SERVICENATURAL GAS VENT-FREEFIREPLACE SYSTEM ILLUSTRATED PARTS BREAKDOWNFMH26TN PARTS LIST FMH26TNDESCRIPTION PARTS AVAILABLE - NOT SHOWNACCESSORIES CLEANING KIT - GCKEQUIPMENT SHUTOFF VALVE - GA5010 BRASS TRIM KIT - GA6094Page WARRANTY INFORMATION LIMITED WARRANTYNOT A UPC Model Serial No Date Purchased