FIREPLACE INSTALLATION
Check Gas Type Installing Optional Blower Accessories
17
FIREPLACE INSTALLATION
.CHECK GAS TYPE
Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type
INSTALLING OPTIONAL BLOWER
ACCESSORIES
NOTICE:The CHDV model fireplaces come with the BKT Blower already installed as standard equipment. If you have a CHDV model fireplace, proceed to Installing Gas Piping to Fireplace Locations, page 19.
NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas supply and dis- connect heater from gas supply. Contact a qualified service person to do this.
WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury.
Model BK Installation
Follow all instructions provided in the blower accessory kit.
1.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 25).
2.Attach green ground wire from power cord to blower housing using screw provided (see Figure 25). Tighten screws securely.
Blower
Location
Lower Firebox
Cavity
Side View
Magnetic Strips
Spade Terminals | Exhaust |
| Port |
3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 25).
4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight.
5.Mount speed control box to switch bracket by placing the plastic control shaft forward through the round opening in the switch bracket (see Figure 26).
6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob provided on shaft.
7.Turn on power to duplex outlet if previously turned off per the warning in column 1.
8.Plug in blower power cord.
a.If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox.
b.If your firebox installation is recessed and/or
CAUTION: Never touch the blower wheel while in operation.
Switch | Speed Control |
Bracket | Blower |
| |
|
Control
Knob
Locknut | Control | Duplex Outlet |
| Shaft | |
| (Located underneath | |
|
| |
|
| firebox floor against |
|
| lower right outside wall) |
Figure 26 - Attaching Speed Control to Firebox
Green
Ground Wire
Figure 25 - Blower Model BK
Screw