Desa CHDV47PR REMOVING/REPLACING Glass Door, Removing Louver Panels, Removing Glass Doors

Page 23

FIREPLACE INSTALLATION

Removing/Replacing Glass Door Installing Optional Brick Liner Models BL36D(S), BL36DH(S), BL42D(S), BL42DH(S)

23

FIREPLACE INSTALLATION

Continued

REMOVING/REPLACING GLASS DOOR

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part infor- mation see Replacement Parts, page 33.

6.Replace screen/rod assembly by reversing step 1.

7.Replace louvers by reversing procedure under Removing Louver Panels.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before removing glass door or louvers.

Latch

Screw

Unlock Lock

Removing Louver Panels

Remove the top and bottom louver panels by simultaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating holes (see Figure 41). Repeat for bottom spring latches and pull the louvers outward. To install or replace items removed, simply reverse the procedures above.

Louver Panel

Spring Latch

Figure 41 - Removing Louver Panel

Removing Glass Doors

If replacement of glass is necessary, the entire assembly, glass and frame, must be replaced. If glass is broken, wear gloves and tape the remaining fragments onto the frame.

1.Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen/rod assembly from the firebox. Set assembly aside.

2.Lift up on latches to unlock. There are two on top of firebox and two below firebox that hold glass door in place (see Figure 42).

3.While holding glass door to prevent it from falling and caus- ing injury, remove the five screws from the hinge located on the left side of door frame assembly (see Figure 42).

4.Remount the new frame at the hinge with five new screws before closing door. This will ensure seating of the gasket.

5.Close glass door frame. Lock latches by placing the bar under the tab on door and pushing down and back on latch (see Figure 42).

Hinge

Glass Frame

Assembly

Figure 42 - Removing/Replacing Glass Door

Cleaning Glass Door

See Cleaning and Maintenance on page 29.

INSTALLING OPTIONAL BRICK LINER MODELS BL36D(S), BL36DH(S), BL42D(S), BL42DH(S)

WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before installing brick liner.

This brick liner kit is optional. You may purchase brick liner from your local retailer or see Accessories, pages 42 and 43.

CAUTION: Always handle brick panels with two hands. Do not force brick panels into place. Exces- sive force will break brick panels.

1.Remove top and bottom louvers to allow access to door latches.

2.Unlock door latches and open glass door. See Removing/Re- placing Glass Door, steps 1 and 2.

3.If installing brick liner in new fireplace, go to step 4. If install- ing brick liner in an existing fireplace, carefully remove logs, lava rock, and ember material.

4.Remove three screws from deflector shield on the inside top of firebox. Set shield and screws aside.

For morevisit www..com

108861

Image 23
Contents For Your Safety What to do if YOU Smell GAS TM OWNER’S Operation Installation ManualCHDV47NR CHDV47PR For Your Safety Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Ground Floor Installation Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Desa International Elbows High Altitude InstallationDesa International 5/8 Pipe & Vent Kits Desa International Terminations Desa International Venting AccessoriesCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessories Model BK InstallationBlower Model BKT Model BKT InstallationBlower Wiring Diagram Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemChecking Gas Joints for Propane/LP Gas Fireplace Pressure Testing Fireplace Gas ConnectionsReplace the switch bracket Removing Glass Doors Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No 36 and 42 Series and Log No 42 Series Only Lighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceCghrcta Series Operation Optional Remote OperationCghrc Series Operation Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Parts Under Warranty Replacement Parts Service HintsSpecifications Technical ServiceIllustrated Parts Breakdown Description QTY Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY 23-6 23-5 23-2 23-7 23-1 23-4 23-3 CHDV47NR Illustrated Parts Breakdown KEY Part Number Description QTY Accessories Wall Mounted Thermostat Control Receiver and HAND-HELD ON/OFF Remote Control KIT Ghrc SeriesWarranty Information