OPERATING FIREPLACE
Optional Remote Operation
27
OPERATING FIREPLACE
Continued
OPTIONAL REMOTE OPERATION
Note: All remote control accessories must be purchased sepa- rately (see Accessories, pages 42 and 43). Follow instructions included with the remote control.
(Optional [C]GHRCT[A] Only) The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The burners will turn on and off automati- cally to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
NOTICE: You must light the pilot before using the
1.After lighting, let pilot flame burn for about one minute. Turn gas control knob to ON position. Adjust variable control knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 53). Note: The burners may light if
IMPORTANT: Do not leave the selector switch in the RE- MOTE position when the pilot is not lit. This will drain the battery.
IMPORTANT: Be sure to press the ON/OFF buttons on the
IMPORTANT: This remote control has been specially engineered to take an air temperature sample every 5.5 minutes in the auto mode. It will not respond immedi- ately to the temperature setting being turned up or down. IMPORTANT: The
3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.
IMPORTANT: To turn the pilot off, manually turn the con- trol knob on the heater to the OFF position.
Selector Switch in |
| Blower Control Knob |
|
|
|
Remote Position |
| (Optional Accessory) |
|
| Variable |
|
|
|
|
| |
|
|
|
|
| Control Knob |
|
| OFF |
|
|
|
|
| ON |
|
|
|
|
| N |
| L |
|
|
| O |
| O | I |
ON | OFF REMOTE | T | F | O | H |
O |
|
| |||
|
| F |
|
| |
|
| LIP |
|
|
|
|
| Gas Control Knob | |||
|
| in ON Position |
Figure 53 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation
(C)GHRC Series Operation:
2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.
(C)GHRCT(A) Series Operation:
2b. Press the AUTO/ON/OFF button on the
• | In the ON mode, the burners will ignite. The heater is in |
| manual mode when ON is lit. |
• | In the AUTO mode, the thermostat in the |
| mote unit controls the room temperature. To increase the |
Shows
Temperature
Setting
The Log Heater will Automatically Cycle between Pilot and the Heat
Setting that has been Selected
Increases Room
Temperature in
AUTO Mode
Decreases Room
Temperature in
AUTO Mode
Turns Burners On
or Off and Allows
You to Choose the
Auto Setting
room temperature, press the top arrow of the TEMP but- |
ton. To lower the room temperature, press the bottom |
arrow of the TEMP button. At higher settings the heater |
will run longer. |
Figure 54 - Thermostat Hand-Held Remote Control Unit Selections ([C]GHRCT[A] Series Only)
For morevisit www..com
108861