Desa CHDV47NR, (V)V36N, CHDV47PR installation manual Replace the switch bracket

Page 22

22

FIREPLACE INSTALLATION

Installing Optional Wireless Hand-Held Remote Control - RC, GHRC, CGHRC, (C)GHRCT(A) Series

FIREPLACE INSTALLATION

Continued

INSTALLING OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL - (C)GHRC AND (C)GHRCT(A) SERIES

NOTICE: Use only alkaline batteries (not included).

Installing Remote Receiver

Installing 9-Volt Alkaline Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to a 9-volt alkaline battery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote control unit.

1.

Open bottom louver and locate the switch bracket on the left.

2.

Unscrew the switch bracket. Lean bracket forward so you are

 

able to access the back of the remote receiver.

3.

Locate the battery clip mounted on the back of the receiver.

 

Slide a 9-volt alkaline battery (not included) through the clip

 

(see Figure 36).

4.

Attach the terminal wires to the battery.

Battery Cover

Terminal

Wires

9-Volt Alkaline Battery

Remote Control Unit

Battery

Housing

5.

Remove wire from TH to TPTH on control valve (see Figure 37).

6.

Connect wires from receiver to TH and TPTH to control valve

 

(see Figure 38).

7.

Replace the switch bracket.

Receiver

 

9-Volt

Terminal

Alkaline

Battery

Wires

 

Battery Clip

Figure 36 - Attaching Alkaline Battery to Receiver

Figure 39 - Installing Alkaline Battery in Hand-Held Remote Control Unit ([C]GHRC)

Terminal

9-Volt Wires

Battery

Remote

Control

Unit

Battery

Cover

Figure 40 - Installing Battery in Hand-Held Remote Control Unit ([C]GHRCT[A] Series)

Figure 37 - Disconnecting TH to TPTH Wire

To Optional

Remote

Accessory

Figure 38 - Control Valve Terminals

For..com

108861

Image 22
Contents CHDV47NR CHDV47PR For Your Safety TM OWNER’S Operation Installation ManualFor Your Safety What to do if YOU Smell GAS Table of Contents Safety InformationSafety Information Product Identification Local CodesPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Siding Standoff Horizontal Termination Configurations Ground Floor InstallationCorner Installation Venting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Desa International 5/8 Pipe & Vent Kits High Altitude InstallationDesa International Elbows Desa International Venting Accessories Desa International TerminationsModel BK Installation Fireplace InstallationInstalling Optional Blower Accessories Check GAS TypeModel BKT Installation Blower Model BKTInstalling GAS Piping to Fireplace Location Blower Wiring DiagramPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Checking Gas Joints for Propane/LP Gas FireplaceReplace the switch bracket Removing Louver Panels Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Glass DoorsInstalling LOGS, Lava Rock and Glowing Embers Installing Rear Brick PanelInstalling Log No 36 and 42 Series and Log No 42 Series Only Operating Fireplace For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsCghrc Series Operation Optional Remote OperationCghrcta Series Operation Inspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Replacement Parts Service HintsSpecifications Parts Under WarrantyIllustrated Parts Breakdown Parts List Description QTYIllustrated Parts Breakdown KEY Part Number Description QTY 23-6 23-5 23-2 23-7 23-1 23-4 23-3 CHDV47NR Illustrated Parts Breakdown KEY Part Number Description QTY Accessories Receiver and HAND-HELD ON/OFF Remote Control KIT Ghrc Series Wall Mounted Thermostat ControlWarranty Information