Desa (V)V42NA(1) High Altitude Installation, Vertical Venting, Number Description

Page 15

VENTING INSTALLATION INSTRUCTIONS

Installation for Vertical Termination (Cont.) High Altitude Installation Parts Lists for Venting Kits and Components for V42 and VV42 Series

15

VENTING INSTALLATION INSTRUCTIONS

Continued

Vertical Venting

V = 40' max.

Note: Install restrictor into inner collar of fireplace as shown.

45° Elbow

Figure 24 - Vertical Venting Configuration With No Horizontal Run (Vertical Round High Wind Termination Shown)

HIGH ALTITUDE INSTALLATION

Your DESA direct-vent fireplace has been tested and approved for elevations from 0-2000 feet (USA) and elevations from 0-4500 feet (Canada).

When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orificetoasmallersize.Reduceinput4%foreach1000feetabovesealevel. Check with your local gas company for proper orifice size identification.

When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities.

Consult your local gas company to help determine the proper orifice for your location.

For assistance with any high altitude installation contact DESA’s Customer Service Department at 1-866-672-6040.

PARTS LISTS FOR VENTING KITS AND COMPONENTS FOR V42 AND VV42 SERIES DESA (5/8") Pipe & Vent Kits

Number

Description

P58-6

6" Section Double Wall Pipe, Galvanized

P58-12

12" Section Double Wall Pipe, Galvanized

P58-24

24" Section Double Wall Pipe, Galvanized

P58-36

36" Section Double Wall Pipe, Galvanized

P58-48

48" Section Double Wall Pipe, Galvanized

PA58-712

Adjustable 7"-12" Section Double Wall Pipe, Galva-

 

nized

FPA58-6

6" Duravent Collar to FMI Pipe Adaptor (6" collar/Pipe

 

Section)

DPA58-6

6" FMI Collar to Pipe Duravent Adaptor (6" collar/Pipe

 

Section)

E58-45

45 deg. Elbow, Galvanized

E58-90

90 deg. Elbow, Galvanized

FSE58-45

45 deg. Starter Elbow, Galvanized (Duravent Collar to

 

FMI Pipe)

DSE58-45

45 deg. Starter Elbow, Galvanized (FMI Collar to

 

Duravent Pipe)

VKG-58

Ground Floor Vent Kit

VKB-58

Basement Vent Kit

VKS-58

Snorkel Vent Kit

VKR-58

Roof Vent Kit

VKC-58

Corner Vent Kit

HTK

Horizontal Round Termination Kit

HT-58

Horizontal Round Termination, Galvanized

HTS-58

Horizontal Square Termination, Galvanized

VT-58

Vertical Round Termination, Galvanized

ST-58-14

14" Snorkel Termination, Galvanized

ST-58-36

36" Snorkel Termination, Galvanized

SC-58

Storm Collar, Galvanized

WF-58

Wall Firestop, Galvanized

RF-58-6

Roof Flashing - 0 to 6/12 Pitch, Galvanized

RF-58-12

Roof Flashing - 6/12 to 12/12 Pitch, Galvanized

VR-58

Vertical Restrictor, Galvanized

S-58

Vinyl Siding Standoff, Galvanized

WS-58

Wall Strap

CS-58

Cathedral Ceiling Support

For morevisit www..com

111906-01A

Image 15
Contents OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with Two 90 Elbows Venting with One 90 Elbow Vertical Termination ConfigurationsHigh Altitude Installation Vertical VentingNumber Description Desa Terminations Desa Venting AccessoriesDesa 5/8 Pipe & Vent Kits Desa ElbowsCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessories Model BK InstallationBlower Model BKT Model BKT InstallationInstalling GAS Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemChecking Gas Joints for Propane/LP Gas Fireplace Pressure Testing Fireplace Gas ConnectionsReplace the switch bracket Removing Glass Doors Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No and Log No Lighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceOptional HAND-HELD Remote Operation Thermostat Series Models Ghrctb and CghrctbON/OFF Series Models Ghrcb and Cghrcb Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceCHDV42NRA Illustrated Parts BreakdownCHDV42NRA Description QTY Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY Accessories Owners Registration Form Postage Required 111906-01A Warranty Information

(V)V42NA(1) specifications

Desa (V)V42NA(1) is a sophisticated model designed for a wide range of applications, showcasing advanced features and cutting-edge technologies that make it stand out in its category. This model is particularly noted for its efficiency and robustness, catering to both commercial and residential needs.

One of the primary features of the Desa (V)V42NA(1) is its enhanced energy efficiency. It is engineered to optimize fuel consumption while delivering superior performance. This efficiency is primarily achieved through the use of innovative combustion technology that ensures a cleaner and more controlled burn, resulting in lower emissions. This environmental consideration makes it a suitable choice for eco-conscious consumers, aligning with global trends towards sustainability.

The Desa (V)V42NA(1) is equipped with a user-friendly interface, which allows for easy operation and control. Its digital display provides real-time information on performance parameters, making it easy for users to monitor and adjust settings as needed. This aspect of the design emphasizes user convenience and accessibility.

Another key characteristic is its adaptability. The model can easily be integrated into various settings, whether as a stand-alone unit or as part of a larger system. It is compatible with various heating and cooling technologies, making it versatile for both new installations and retrofitting projects. This flexibility is further enhanced by the availability of optional accessories that allow users to customize the unit according to their specific requirements.

Durability is another standout feature of the Desa (V)V42NA(1). Built with high-quality materials, this model is designed to withstand the rigors of everyday use while requiring minimal maintenance. This reliability ensures longevity, making it a cost-effective choice for users looking for a long-term heating solution.

In summary, the Desa (V)V42NA(1) exemplifies a harmonious blend of efficiency, user-friendliness, versatility, and durability. Its advanced technologies and features cater to a wide variety of needs, establishing it as a standout product in the heating technology market. As consumers continue to seek efficient and reliable solutions, the Desa (V)V42NA(1) stands ready to meet these growing demands.