Desa (V)V42NA(1) installation manual Gas leak. See Warning statement, Above

Page 32

32

TROUBLESHOOTING

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces unwanted odors

1. Gas leak. See Warning statement

 

above

1.Locate and correct all leaks (see Check- ing Gas Connections, page 20)

Fireplace shuts off in use

1.

High or gusting winds

1.

Fireplace has been tested for up to

 

 

 

 

 

40mph winds. However, extreme con-

 

 

 

 

 

ditions may occur. See Lighting Instruc-

 

 

 

 

 

tions on page 26

 

 

2.

Low line pressure

2.

Contact local propane/LP or natural gas

 

 

 

 

 

company

 

 

3.

Pilot is partially clogged

3.

Clean pilot (see Cleaning and Mainte-

 

 

 

 

 

nance, page 29)

 

 

4.

Inner vent pipe leaking exhaust gasses

4.

Locate and correct all leaks (see Check-

 

 

 

into system

 

ing Gas Connections, page 20)

 

 

5.

Glass too loose and air tight gasket leaks

5.

Tighten glass

 

 

 

in corners after usage

 

 

 

 

 

6.

Bad thermopile or thermocouple

6.

Replace faulty component

 

 

7.

Improper vent cap installation

7.

Check for proper installation and free-

 

 

 

 

 

dom from debris or blockage

 

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

above

 

ing Gas Connections, page 20)

 

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

 

 

Gas odor during combustion

1. Gas leak. See Warning statement

 

above

1.Locate and correct all leaks (see Check- ing Gas Connections, page 20)

Dark residue on logs or inside of fireplace

1.

Improper log placement

1.

Properly locate logs (see Installing Logs,

 

 

 

 

Lava Rock, and Glowing Embers, pages

 

 

 

 

24 and 25)

 

2.

Air holes at burner inlet blocked

2.

Clean out air holes at burner inlets. Pe-

 

 

 

 

riodically repeat as needed

 

3.

Burner flame holes blocked

3.

Remove blockage

For..com

111906-01A

Image 32
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Table of Contents Safety InformationSafety Information Product Identification Local CodesLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Termination Configurations Horizontal HCorner Installation Horizontal System Installation Using TWO Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with Two 90 Elbows Venting with One 90 ElbowNumber Description High Altitude InstallationVertical Venting Desa Venting Accessories Desa 5/8 Pipe & Vent KitsDesa Elbows Desa TerminationsFireplace Installation Installing Optional Blower AccessoriesModel BK Installation Check GAS TypeModel BKT Installation Blower Model BKTInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Connecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Checking Gas Joints for Propane/LP Gas FireplaceReplace the switch bracket Cleaning Glass Door REMOVING/REPLACING Glass DoorRemoving Louver Panels Removing Glass DoorsInstalling LOGS, Lava Rock and Glowing Embers Installing Rear Brick PanelInstalling Log No and Log No For Your Safety Read Before Lighting Manual Lighting ProcedureOperating Fireplace Lighting InstructionsON/OFF Series Models Ghrcb and Cghrcb Optional HAND-HELD Remote OperationThermostat Series Models Ghrctb and Cghrctb Operating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveReplacement Parts Service HintsTechnical Service SpecificationsIllustrated Parts Breakdown CHDV42NRAParts List CHDV42NRA Description QTYIllustrated Parts Breakdown KEY Part Number Description QTY Accessories Owners Registration Form Postage Required 111906-01A Warranty Information

(V)V42NA(1) specifications

Desa (V)V42NA(1) is a sophisticated model designed for a wide range of applications, showcasing advanced features and cutting-edge technologies that make it stand out in its category. This model is particularly noted for its efficiency and robustness, catering to both commercial and residential needs.

One of the primary features of the Desa (V)V42NA(1) is its enhanced energy efficiency. It is engineered to optimize fuel consumption while delivering superior performance. This efficiency is primarily achieved through the use of innovative combustion technology that ensures a cleaner and more controlled burn, resulting in lower emissions. This environmental consideration makes it a suitable choice for eco-conscious consumers, aligning with global trends towards sustainability.

The Desa (V)V42NA(1) is equipped with a user-friendly interface, which allows for easy operation and control. Its digital display provides real-time information on performance parameters, making it easy for users to monitor and adjust settings as needed. This aspect of the design emphasizes user convenience and accessibility.

Another key characteristic is its adaptability. The model can easily be integrated into various settings, whether as a stand-alone unit or as part of a larger system. It is compatible with various heating and cooling technologies, making it versatile for both new installations and retrofitting projects. This flexibility is further enhanced by the availability of optional accessories that allow users to customize the unit according to their specific requirements.

Durability is another standout feature of the Desa (V)V42NA(1). Built with high-quality materials, this model is designed to withstand the rigors of everyday use while requiring minimal maintenance. This reliability ensures longevity, making it a cost-effective choice for users looking for a long-term heating solution.

In summary, the Desa (V)V42NA(1) exemplifies a harmonious blend of efficiency, user-friendliness, versatility, and durability. Its advanced technologies and features cater to a wide variety of needs, establishing it as a standout product in the heating technology market. As consumers continue to seek efficient and reliable solutions, the Desa (V)V42NA(1) stands ready to meet these growing demands.