Desa (V)V42NA(1) installation manual Clearances, Framing and Finishing

Page 5

PRE-INSTALLATION PREPARATION

Clearances

Framing and Finishing

5

PRE-INSTALLATION

PREPARATION

Continued

CLEARANCES

Minimum clearances to combustibles for the fireplace are as follows:

Back, and sides

0"/mm

Perpendicular walls

6" (152mm)

Floor

0"/mm

Ceiling to louver opening

42" (1067mm)

Front

36" (914mm)

Top of Standoffs

0"/mm

Vent

(See venting instructions for

 

specific venting clearances.)

Combustible material with a maximum thickness of 5/8" may be flush with the top front of fireplace .

215/8"131/2"

415/8"

163/4"

48"

481/4"

811/2"

581/2"

Nailing Tabs

NOTICE: This fireplace is intended for use as supple- mental heat. Use this fireplace along with your pri- mary heating system. Do not install this fireplace as your primary heat source. If you have a central heat- ing system, you may run system’s circulating blower while using fireplace. This will help circulate the heat throughout the house. In the event of a power outage, you can use this fireplace as a heat source.

FRAMING AND FINISHING

Figure 4 shows typical framing of this fireplace. Figure 5 shows framing for corner installation. All minimum clearances must be met.

For available accessories for this fireplace, see Accessories on pages

38.If you are using a separate combustible mantel piece, refer to Figure 6 for proper installation height. You can install noncombus- tible mantels at any height above the fireplace.

Note: Noncombustible mantels may discolor!

401/8"

481/4"

25 5/8"

Figure 4 - Framing Clearances for Installation Against an Exterior Wall

Figure 5 - Framing Clearances for Corner Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

Wall

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of Louver Opening

 

 

 

 

 

 

 

Ref.

Mantel Depth

Ref.

Mantel from Top

 

 

 

 

 

 

 

 

 

 

 

 

of Louver Opening

 

 

 

1

14" (356mm)

 

A

 

 

 

16" (406mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

12" (305mm)

 

B

 

 

 

14" (356mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

10" (254mm)

 

C

 

 

 

12" (305mm)

 

 

 

4

8" (203mm)

 

D

 

 

 

10" (254mm)

 

 

 

5

6" (152mm)

 

E

 

 

 

8" (203mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

4" (101mm)

 

F

 

 

 

6" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

2" (51mm)

 

G

 

 

 

4" (101mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 6 - Clearances for Combustible Mantels

For morevisit www..com

111906-01A

Image 5
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with Two 90 Elbows Venting with One 90 Elbow Vertical Termination ConfigurationsNumber Description High Altitude InstallationVertical Venting Desa 5/8 Pipe & Vent Kits Desa Venting AccessoriesDesa Elbows Desa TerminationsInstalling Optional Blower Accessories Fireplace InstallationModel BK Installation Check GAS TypeBlower Model BKT Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Installation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsChecking Gas Joints for Propane/LP Gas Fireplace Pressure Testing Fireplace Gas ConnectionsReplace the switch bracket REMOVING/REPLACING Glass Door Cleaning Glass DoorRemoving Louver Panels Removing Glass DoorsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No and Log No Manual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsON/OFF Series Models Ghrcb and Cghrcb Optional HAND-HELD Remote OperationThermostat Series Models Ghrctb and Cghrctb Pilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementService Hints Replacement PartsTechnical Service SpecificationsCHDV42NRA Illustrated Parts BreakdownCHDV42NRA Description QTY Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY Accessories Owners Registration Form Postage Required 111906-01A Warranty Information

(V)V42NA(1) specifications

Desa (V)V42NA(1) is a sophisticated model designed for a wide range of applications, showcasing advanced features and cutting-edge technologies that make it stand out in its category. This model is particularly noted for its efficiency and robustness, catering to both commercial and residential needs.

One of the primary features of the Desa (V)V42NA(1) is its enhanced energy efficiency. It is engineered to optimize fuel consumption while delivering superior performance. This efficiency is primarily achieved through the use of innovative combustion technology that ensures a cleaner and more controlled burn, resulting in lower emissions. This environmental consideration makes it a suitable choice for eco-conscious consumers, aligning with global trends towards sustainability.

The Desa (V)V42NA(1) is equipped with a user-friendly interface, which allows for easy operation and control. Its digital display provides real-time information on performance parameters, making it easy for users to monitor and adjust settings as needed. This aspect of the design emphasizes user convenience and accessibility.

Another key characteristic is its adaptability. The model can easily be integrated into various settings, whether as a stand-alone unit or as part of a larger system. It is compatible with various heating and cooling technologies, making it versatile for both new installations and retrofitting projects. This flexibility is further enhanced by the availability of optional accessories that allow users to customize the unit according to their specific requirements.

Durability is another standout feature of the Desa (V)V42NA(1). Built with high-quality materials, this model is designed to withstand the rigors of everyday use while requiring minimal maintenance. This reliability ensures longevity, making it a cost-effective choice for users looking for a long-term heating solution.

In summary, the Desa (V)V42NA(1) exemplifies a harmonious blend of efficiency, user-friendliness, versatility, and durability. Its advanced technologies and features cater to a wide variety of needs, establishing it as a standout product in the heating technology market. As consumers continue to seek efficient and reliable solutions, the Desa (V)V42NA(1) stands ready to meet these growing demands.