Desa (V)V42NA(1) REMOVING/REPLACING Glass Door, Removing Louver Panels, Removing Glass Doors

Page 23

FIREPLACE INSTALLATION

Removing/Replacing Glass Door Installing Optional Brick Liner Models BL42DA(SA) and BL42DHA(SA)

23

FIREPLACE INSTALLATION

Continued

REMOVING/REPLACING GLASS DOOR

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part infor- mation see Replacement Parts, page 33.

6.Replace screen/rod assembly by reversing step 1.

7.Replace louvers by reversing procedure under Removing Louver Panels.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before removing glass door or louvers.

Latch

Screw

Unlock Lock

Removing Louver Panels

Remove the top and bottom louver panels by simultaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating holes (see Figure 41). Repeat for bottom spring latches and pull the louvers outward. To install or replace items removed, simply reverse the procedures above.

Louver Panel

Spring Latch

Figure 41 - Removing Louver Panel

Removing Glass Doors

If replacement of glass is necessary, the entire assembly, glass and frame, must be replaced. If glass is broken, wear gloves and tape the remaining fragments onto the frame.

1.Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen/rod assembly from the firebox. Set assembly aside.

2.Lift up on latches to unlock. There are two on top of firebox and two below firebox that hold glass door in place (see Figure 42).

3.While holding glass door to prevent it from falling and caus- ing injury, remove the five screws from the hinge located on the left side of door frame assembly (see Figure 42).

4.Remount the new frame at the hinge with five new screws before closing door. This will ensure seating of the gasket.

5.Close glass door frame. Lock latches by placing the bar under the tab on door and pushing down and back on latch (see Figure 42).

Hinge

Glass Frame

Assembly

Figure 42 - Removing/Replacing Glass Door

Cleaning Glass Door

See Cleaning and Maintenance on page 29.

INSTALLING OPTIONAL BRICK LINER MODELS BL42DA(SA) AND BL42DHA(SA)

WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before installing brick liner.

This brick liner kit is optional. You may purchase brick liner from your local retailer or see Accessories, page 38.

CAUTION: Always handle brick panels with two hands. Do not force brick panels into place. Exces- sive force will break brick panels.

1.Remove top and bottom louvers to allow access to door latches.

2.Unlock door latches and open glass door. See Removing/Re- placing Glass Door, steps 1 and 2.

3.If installing brick liner in new fireplace, go to step 4. If install- ing brick liner in an existing fireplace, carefully remove logs, lava rock, and ember material.

4.Remove three screws from deflector shield on the inside top of firebox. Set shield and screws aside.

For morevisit www..com

111906-01A

Image 23
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with Two 90 Elbows Venting with One 90 Elbow Vertical Termination ConfigurationsNumber Description High Altitude InstallationVertical Venting Desa Terminations Desa Venting AccessoriesDesa 5/8 Pipe & Vent Kits Desa ElbowsCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessories Model BK InstallationBlower Model BKT Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemChecking Gas Joints for Propane/LP Gas Fireplace Pressure Testing Fireplace Gas ConnectionsReplace the switch bracket Removing Glass Doors Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No and Log No Lighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceON/OFF Series Models Ghrcb and Cghrcb Optional HAND-HELD Remote OperationThermostat Series Models Ghrctb and Cghrctb Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceCHDV42NRA Illustrated Parts BreakdownCHDV42NRA Description QTY Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY Accessories Owners Registration Form Postage Required 111906-01A Warranty Information

(V)V42NA(1) specifications

Desa (V)V42NA(1) is a sophisticated model designed for a wide range of applications, showcasing advanced features and cutting-edge technologies that make it stand out in its category. This model is particularly noted for its efficiency and robustness, catering to both commercial and residential needs.

One of the primary features of the Desa (V)V42NA(1) is its enhanced energy efficiency. It is engineered to optimize fuel consumption while delivering superior performance. This efficiency is primarily achieved through the use of innovative combustion technology that ensures a cleaner and more controlled burn, resulting in lower emissions. This environmental consideration makes it a suitable choice for eco-conscious consumers, aligning with global trends towards sustainability.

The Desa (V)V42NA(1) is equipped with a user-friendly interface, which allows for easy operation and control. Its digital display provides real-time information on performance parameters, making it easy for users to monitor and adjust settings as needed. This aspect of the design emphasizes user convenience and accessibility.

Another key characteristic is its adaptability. The model can easily be integrated into various settings, whether as a stand-alone unit or as part of a larger system. It is compatible with various heating and cooling technologies, making it versatile for both new installations and retrofitting projects. This flexibility is further enhanced by the availability of optional accessories that allow users to customize the unit according to their specific requirements.

Durability is another standout feature of the Desa (V)V42NA(1). Built with high-quality materials, this model is designed to withstand the rigors of everyday use while requiring minimal maintenance. This reliability ensures longevity, making it a cost-effective choice for users looking for a long-term heating solution.

In summary, the Desa (V)V42NA(1) exemplifies a harmonious blend of efficiency, user-friendliness, versatility, and durability. Its advanced technologies and features cater to a wide variety of needs, establishing it as a standout product in the heating technology market. As consumers continue to seek efficient and reliable solutions, the Desa (V)V42NA(1) stands ready to meet these growing demands.