INSTALLATION

 

 

 

 

 

 

Continued

 

 

 

 

 

 

 

WARNING: Never attempt to service heater while

 

it is plugged in, operating, or hot. Burns and elec-

 

trical shock could result. Only a qualified service

 

person should service or repair heater.

 

 

 

If any of the original wire as supplied with the appliance must

 

be replaced, original replacements must be used. DESA part

 

no. 104015-01 (105°C) for power cord, and DESA part no.

 

103968-01 (200°C) for wire harness.

 

 

 

 

WARNING: Label all wires prior to disconnection

 

 

when servicing controls. Wiring errors can cause

 

 

improper and dangerous operation. Verify proper

 

 

operation after servicing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Switch

 

 

 

 

 

 

 

(Auto/Off/On)

 

 

 

1

 

Auto

Thermostat

 

 

 

 

 

 

Off 2

 

 

Blue

 

 

 

 

 

 

3

Switch

 

 

 

 

 

 

 

 

 

(N.O.)

 

 

 

 

 

 

 

 

 

 

 

 

 

110/115

On

Blue Blower

 

 

 

 

 

 

 

V.A.C.

 

 

 

 

 

Motor

 

 

 

 

Black

Red

Red

 

 

 

 

 

 

 

 

 

 

 

 

Green

 

 

 

 

White

 

 

 

 

 

 

White

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Green

 

 

 

120 Vac. 60 Hz. .30 Amps

 

 

 

 

DESA Heating Products, Bowling Green, KY

101584-06

 

Figure 18 - Wiring Diagram For Fan

 

 

 

Accessory Built-In Installation

CONNECTING TO GAS SUPPLY

WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.

WARNING: A qualified ser- vice person must connect heater to gas supply. Follow all local codes.

CAUTION:Neverconnectpro- pane/LP fireplace directly to the propane/LPsupply.Thisfireplace requires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply.

WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

ground joint union

sediment trap

tee joint

pipe wrench

test gauge connection *

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 35.

For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 19. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. In- ternally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of volume will occur.

Propane/LP

Supply Tank

External

Regulator

Vent

Pointing

Down

Figure 19 - External Regulator With Vent

Pointing Down

113897-01A

www.desatech.com

15

Image 15
Contents What to do if YOU Smell GAS Table of Contents Safety Information Unpacking Local CodesProduct Features Remote Control AccessoriesProduct Identification Confined and Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeLocating Fireplace Minimum Clearance for Combustible to Wall BUILT-IN Fireplace InstallationAttaching Fireplace to Wall Studs Mantel Clearances for Built-In InstallationTrim shipped with mantel Optional Mantel InstallationRemoving Brick Liner Retainer Assembling TrimRemoving Hood Installing Blower Assembly GA3450TInstalling Blower Bracket Assembly For Built-In Installation Installation Items Needed Connecting to GAS SupplyConnecting Fireplace to GAS Supply Propane/LPNatural From KPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Test Pressures In Excess Of 1/2 PsigPressure Testing Heater GAS Connections Installing LogsInstalling 9-Volt Battery in Receiver Installing Wireless Remote Control AccessoryLighting Instructions For Your Safety Read Before LightingSelector Switch Flame Operating FireplaceManual Lighting Procedure To Turn OFF GAS To ApplianceOptional HAND-HELD Remote Operation Thermostat Series Model Cghrctb ON/OFF Series Model CghrcbInspecting Burners Cleaning MaintenanceExterior Burner Injector Holder and Pilot AIR Inlet HoleCabinet Air PassagewaysObserved Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte On windows Tilation air Gas leak. See Warning Wiring Diagram SpecificationsModels CF26PRA and CF26NRA Illustrated Parts BreakdownParts List 20-1 11-1 20-3 11-2 KEY Part Number Description QTY Parts Central Replacement PartsService Hints Technical ServiceThermostatically Controlled Blower KIT GA3450T Receiver and HAND-HELD Remote Control KIT CghrcbCleaning KIT GCK Equipment Shutoff Valve GA5010Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS BAY Front Fireplace

CF26NRA, CF26PRA specifications

Desa CF26PRA and CF26NRA are highly regarded heating appliances designed for efficient and reliable home heating solutions. These units are part of Desa's comprehensive lineup, known for their innovative technology and user-friendly features. Both models are distinct yet share a common commitment to optimizing warmth and comfort in residential spaces.

One of the main features of the CF26PRA and CF26NRA is their impressive heating capacity. These heaters are engineered to deliver significant BTUs, ensuring that even large rooms are heated rapidly and evenly. Both models utilize a forced air distribution system that effectively circulates warmth throughout the living area, eliminating cold spots and providing a consistent, cozy environment.

In terms of design, the CF26PRA and CF26NRA are visually appealing with modern aesthetics that blend seamlessly into various décors. Their compact size allows for flexible placement, whether freestanding or wall-mounted, making them an ideal choice for any room in the home, including living rooms, basements, or even workshops.

Incorporating advanced technologies, these models are equipped with electronic ignition systems, which eliminate the need for manual lighting, ensuring ease of use. Their adjustable thermostat allows homeowners to set the preferred temperature, automatically regulating heat output to maintain comfort while optimizing energy efficiency.

Both the CF26PRA and CF26NRA are constructed with durable materials that enhance their longevity and performance. This robust build is paired with safety features like automatic shut-off and flame failure protection, providing peace of mind for users, particularly in homes with children or pets.

Energy efficiency is another hallmark of these models. They are designed to consume minimal fuel while maximizing output, which helps in reducing monthly heating costs without sacrificing comfort. The CF26NRA, specifically, features an enhanced combustion system, further improving fuel efficiency and lowering emissions.

In conclusion, Desa CF26PRA and CF26NRA are excellent choices for anyone seeking reliable, efficient, and stylish heating solutions. With their user-friendly features, advanced technology, and strong performance characteristics, both models represent a solid investment for maintaining a warm and inviting home during cold weather months. Whether you're upgrading your heating system or looking for a supplemental heater, these models will meet and exceed expectations, keeping every corner of your home comfortably warm.