Desa BDV37N/P, B) Fireplace Installation, Check GAS Type, Installing Optional Blower Accessory

Page 16

®

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

FIREPLACE INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified ser- vice person must install fireplace. Follow all local codes.

CAUTION: This fireplace cre- ates warm air currents. These cur- rents move heat to wall surfaces next to fireplace. Installing fire- place next to vinyl or cloth wall coverings or operating fireplace where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing mate- rial. See framing details on page 4.

Place the fireplace into position and shim with noncombustible material if needed. Nail the side flanges to the framing to secure the unit in place. There are two floor brack- ets included with each unit. Use these as an alternative method of securing the fireplace.

IMPORTANT: Make sure fireplace is level

CHECK GAS TYPE

Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace according to your gas type.

INSTALLING OPTIONAL

BLOWER ACCESSORY

NOTICE: If installing blower in an existing fireplace with gas con- nections, shut off gas supply and disconnect heater from gas sup- ply. Contact a qualified service person to do this.

Attaching Thermal Switch to DA3610T Thermostatically- Controlled Blower

When installing the DA3610T thermostati- cally-controlled blower accessory, you must first secure the thermal switch to the blower.

1.Remove the two hex head screws on the blower assembly as shown in Figure 30.

2.Place the green wire between the bot- tom hole on the thermal switch bracket and the bottom hole on the blower as- sembly. Insert one of the hex screws into all three pieces and tighten.

3.Insert the top screw through the ther- mal switch bracket and into the blower assembly. Tighten screw.

4.Connect the blue wire on the blower assembly to the right side of the ther- mal switch.

5.Connect the black wire to the left side of the thermal switch.

Thermal Switch

 

with Bracket

White Wire

Black Wire

 

Green Wire

Hex Head

Installing GA3700/DA3610T Blowers

IMPORTANT: For clarity, gas valve as- sembly and grate/burner assembly are not shown in Figures 31 through 34, page 17. They will, however, be in your fireplace when you are installing the blower. Also for clarity the firebox is shown with dotted lines.

1.Open lower louver panel or remove for easier access.

2.Place the blower against the lower rear wall of firebox outer wrapper with the exhaust port directed upward. Align the holes in the top mounting tabs of blower with holes in wall of wrapper (see Fig- ure 31, page 17). Using the two screws provided, mount blower and tighten screws securely.

Note: For DA3610T, make sure the thermal switch is comfortably under the back of the firebox as shown in Figure 32, page 17.

3.Be sure to securely attach all wire ter- minals to terminals on blower motor (and thermal switch where applicable) and that the screw retaining the green ground wire is tight.

4.Remove screws securing the plate con- taining the ON/OFF switch to the bot- tom of the firebox and set aside.

5.Place speed control against back of this plate and push the plastic control shaft through opening (see Figure 33, page 17).

6.While supporting speed control, secure con- trol shaft with lock nut by pushing and turn- ing lock nut with pliers clockwise until tight against the plate. Place control knob pro- vided onto shaft (see Figure 33, page 17).

7.Replace plate containing switches and tighten screws securely.

Blower Assembly

before securing. If fireplace is not level it will not work properly.

Screws

Blue Wire

Figure 30 - Attaching Thermal Switch to DA3610T Thermostatically-Controlled Blower Accessory

16

105539

Image 16
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyBDV41N/PA,B, and DDV41N/PA,B Safety Information DIRECT-VENT Fireplace NATURAL/PROPANE/LPProduct Features Product IdentificationLocal Codes Glossary TermsPRE-INSTALLATION Preparation ClearancesLocation and Space Requirements Framing and FinishingPRE-INSTALLATION Preparation General Venting Location of Vent TerminationGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Flat Ceiling Installation Installation for VERTI- CAL TerminationCathedral Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Rigid Venting Configuration Using Two 90 Elbows Vertical VentingHigh Altitude Installation Parts Lists for Venting Kits and ComponentsVanguard Rigid Venting Vanguard Flexible VentingFireplace Installation Installing Optional Blower AccessoryInstalling GA3700/DA3610T Blowers Check GAS TypeAs a freestanding unit with an ac Side ViewInstalling GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Close manual shutoff valve see Fig- ureREMOVING/REPLACING Glass Door Attaching Magnetic Decorative Brass Strips DDV OnlyInstalling Optional Brick Liner D8037A/D8041 Installing Left Side Brick PanelInstalling LOGS, Lava Rock and Glowing Embers Fireplace Models BDV37N/PA, BInstalling Log Assembly No Fireplace Models DDV37N/PA, B DDV41N/PA, BFor Your Safety Read Before Lighting Manual Lighting ProcedureOperating Fireplace Lighting InstructionsOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Optional Remote OperationCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveReplacement Parts Wiring DiagramTechnical Service Service HintsSpecifications BDV/DDV37NA,B BDV/DDV37PA,B BDV/DDV41NA,B BDV/DDV41PA,BAccessories Manual Blower KIT GA3700Cabinet Mantel with Square LEG Styling Brass Louver KIT Brick LinerIllustrated Parts Breakdown BDV37NA,B BDV41NA,BParts List DIRECT-VENT Fireplace BDV37NA,B BDV41NA,BBDV37PA,B BDV41PA,B DIRECT-VENT Fireplace BDV37PA,B BDV41PA,B DDV37NA,B DDV41NA,B DIRECT-VENT Fireplace DDV37NA,B DDV41NA,B DDV37PA,B DIRECT-VENT Fireplace DDV37PA,B DDV41PA,B Warranty Information

DDV41N/P, BDV37N/P, BDV41N/P, B), DDV37N/P specifications

Desa B), DDV41N/P, DDV37N/P, BDV37N/P, and BDV41N/P represent a family of advanced heating, ventilation, and air conditioning (HVAC) systems. These models are designed to provide efficient climate control in both residential and commercial environments. They incorporate state-of-the-art technology and superior engineering, offering an optimal combination of performance, energy efficiency, and user comfort.

One of the main features of these units is their enhanced energy efficiency. Each model is built with high-efficiency compressors and advanced heat exchange technology that significantly reduces energy consumption compared to traditional HVAC systems. This not only lowers utility bills but also minimizes the environmental impact by reducing greenhouse gas emissions.

The DDV and BDV series are equipped with cutting-edge inverter technology. This allows the units to adjust their cooling and heating output in response to changing indoor conditions. Consequently, they maintain a consistent temperature while consuming less energy. This inverter-driven operation translates into quieter performance and longer lifespan for the systems, as they experience less wear and tear.

The Desa B) series, along with the DDV41N/P and DDV37N/P, features advanced filtration systems that improve indoor air quality. These filters effectively capture dust, allergens, and other airborne pollutants, making them ideal for households with allergy sufferers or for commercial spaces requiring a clean environment. Furthermore, the user-friendly interfaces and remote control options make operation convenient for users, allowing for easy temperature adjustments and system monitoring.

The BDV37N/P and BDV41N/P models stand out with their versatile installation options. They can be configured for ducted, ductless, or multi-zone systems, making them adaptable to various architectural layouts and design preferences. This flexibility ensures that they can provide the perfect solution for any space, whether it's a compact apartment or a sprawling office building.

Additionally, these models are designed with durability in mind, utilizing high-quality materials that withstand various environmental conditions. They come with robust warranties, ensuring peace of mind for users. With their combination of energy efficiency, advanced technology, and user-friendly features, the Desa B), DDV41N/P, DDV37N/P, BDV37N/P, and BDV41N/P HVAC systems are an excellent choice for anyone seeking optimal climate control solutions. Whether for residential or commercial use, these units deliver comfort and reliability, marking a significant advancement in HVAC technology.