Desa BDV41N/P Operating Fireplace, For Your Safety Read Before Lighting, Lighting Instructions

Page 25

OWNER’S MANUAL

OPERATING

FIREPLACE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information in column one.

2.Open lower louver panel.

3.Turn ON/OFF switch to “OFF”.

4.Turn off all electric power to the fireplace.

5.Push in gas control knob slightly and

turn clockwise to “OFF”.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation in column one. If you don't smell gas, go to the next step.

7.The pilot is located by the main burner and should not require ac- cessing for lighting.

8.Turn gas control knob counterclock-

wise to “PILOT”.

9.Push in gas control knob all the way and hold. Immediately light the pi- lot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If gas control knob does not pop up when released, stop and imme- diately call your service technician or gas supplier.

If the pilot will not stay lit after sev- eral tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

10.Turn gas control knob counterclock-

wise to “ON”.

Gas Control Knob

Variable Control Knob

Piezo

 

 

Ignitor

 

 

IL T

 

IH

O

 

 

P

O

 

F

N

 

F

 

 

O

 

 

 

 

LO

11.Turn on all electric power to the fireplace.

12.Turn the ON/OFF switch to ON position.

13.This valve is equipped with a HI/LO feature. Set fireplace input as desired.

14.Close lower louver panel.

TO TURN OFF GAS

TO APPLIANCE

1.Open lower louver panel.

2a. Turn ON/OFF switch to “OFF”.

2b. If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to prevent draining battery.

3.Turn off all electrical power to the appliance if service is to be performed.

4.Push in gas control knob slightly and

turn clockwise to “OFF”.

5.Close lower louver panel.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn gas control knob clockwise to the PILOT position.

2.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/ Replacing Glass Door, page 21).

2.Follow steps 1 through 8 under Light- ing Instructions.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 seconds after lighting pilot. Af- ter 30 seconds, release gas control knob. Now follow steps 10 through 14, column 2.

5.Replace glass door (see Removing/ Replacing Glass Door, page 21).

Figure 54 - Control Valve

Continued

105539

25

Image 25
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyBDV41N/PA,B, and DDV41N/PA,B DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for VERTI- CAL TerminationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Vertical Rigid Venting Configuration Using Two 90 ElbowsParts Lists for Venting Kits and Components High Altitude InstallationVanguard Rigid Venting Vanguard Flexible VentingInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3700/DA3610T Blowers Check GAS TypeSide View As a freestanding unit with an acInstallation Items Needed Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsClose manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsAttaching Magnetic Decorative Brass Strips DDV Only REMOVING/REPLACING Glass DoorInstalling Left Side Brick Panel Installing Optional Brick Liner D8037A/D8041Fireplace Models BDV37N/PA, B Installing LOGS, Lava Rock and Glowing EmbersFireplace Models DDV37N/PA, B DDV41N/PA, B Installing Log Assembly NoManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsPilot Assembly Operating Optional Blower AccessoryInspecting Burners Optional Remote OperationGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementWiring Diagram Replacement PartsTechnical Service Service HintsBDV/DDV37NA,B BDV/DDV37PA,B BDV/DDV41NA,B BDV/DDV41PA,B SpecificationsManual Blower KIT GA3700 AccessoriesCabinet Mantel with Square LEG Styling Brass Louver KIT Brick LinerBDV37NA,B BDV41NA,B Illustrated Parts BreakdownDIRECT-VENT Fireplace BDV37NA,B BDV41NA,B Parts ListBDV37PA,B BDV41PA,B DIRECT-VENT Fireplace BDV37PA,B BDV41PA,B DDV37NA,B DDV41NA,B DIRECT-VENT Fireplace DDV37NA,B DDV41NA,B DDV37PA,B DIRECT-VENT Fireplace DDV37PA,B DDV41PA,B Warranty Information

DDV41N/P, BDV37N/P, BDV41N/P, B), DDV37N/P specifications

Desa B), DDV41N/P, DDV37N/P, BDV37N/P, and BDV41N/P represent a family of advanced heating, ventilation, and air conditioning (HVAC) systems. These models are designed to provide efficient climate control in both residential and commercial environments. They incorporate state-of-the-art technology and superior engineering, offering an optimal combination of performance, energy efficiency, and user comfort.

One of the main features of these units is their enhanced energy efficiency. Each model is built with high-efficiency compressors and advanced heat exchange technology that significantly reduces energy consumption compared to traditional HVAC systems. This not only lowers utility bills but also minimizes the environmental impact by reducing greenhouse gas emissions.

The DDV and BDV series are equipped with cutting-edge inverter technology. This allows the units to adjust their cooling and heating output in response to changing indoor conditions. Consequently, they maintain a consistent temperature while consuming less energy. This inverter-driven operation translates into quieter performance and longer lifespan for the systems, as they experience less wear and tear.

The Desa B) series, along with the DDV41N/P and DDV37N/P, features advanced filtration systems that improve indoor air quality. These filters effectively capture dust, allergens, and other airborne pollutants, making them ideal for households with allergy sufferers or for commercial spaces requiring a clean environment. Furthermore, the user-friendly interfaces and remote control options make operation convenient for users, allowing for easy temperature adjustments and system monitoring.

The BDV37N/P and BDV41N/P models stand out with their versatile installation options. They can be configured for ducted, ductless, or multi-zone systems, making them adaptable to various architectural layouts and design preferences. This flexibility ensures that they can provide the perfect solution for any space, whether it's a compact apartment or a sprawling office building.

Additionally, these models are designed with durability in mind, utilizing high-quality materials that withstand various environmental conditions. They come with robust warranties, ensuring peace of mind for users. With their combination of energy efficiency, advanced technology, and user-friendly features, the Desa B), DDV41N/P, DDV37N/P, BDV37N/P, and BDV41N/P HVAC systems are an excellent choice for anyone seeking optimal climate control solutions. Whether for residential or commercial use, these units deliver comfort and reliability, marking a significant advancement in HVAC technology.