Desa DDV37N/P, BDV41N/P, BDV37N/P, DDV41N/P, B) DIRECT-VENT Fireplace BDV37PA,B BDV41PA,B

Page 37

OWNER’S MANUAL

PARTS LIST

DIRECT-VENT FIREPLACE

BDV37P(A,B)

BDV41P(A,B)

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual.

KEY

 

 

 

NO.

PART NUMBER

DESCRIPTION

QTY.

 

 

 

 

1

104547-02

Top Outer Casing-37"

1

 

104547-03

Top Outer Casing-41"

1

2

104474-02

Outer Casing-37"

1

 

104474-03

Outer Casing-41"

1

3

104548-02

Bottom Outer Casing-37"

1

 

104548-01

Bottom Outer Casing-41"

1

4

104479-12BR

Firebox Assembly-37"

1

 

104479-11BR

Firebox Assembly-41"

1

5

M11084-26

Screw, Hex

52

6

M11084-46

Screw, Hex

8

7

102455-04

Louver, Extruded-37"

2

 

102455-03

Louver, Extruded-41"

2

8

104443-01

Firebox Support, Right

1

9

104486-01

Firebox Support, Left

1

10

104482-01

Switch Bracket

1

11

104483-01

Floor Mounting Bracket

2

12

104491-01

Relief Cover

1

13

104518-01

Relief Cover Gasket

1

14

104527-01

Relief Spring

2

15

104528-01

Relief Washer

2

16

104537-01

Valve Bracket

1

17

104496-02

SIT Valve, Propane/LP

1

18

104497-02

SIT Pilot, Propane/LP

1

19

104498-01

Thermocouple

1

20

104499-01

Thermopile

1

21

104500-01

Piezo Ignitor

1

22

104501-01

Ignitor Bracket

1

23

104502-01

Ignitor Screw

1

24

104503-01

Ignitor Wire

1

25

104504-02

Burner

1

26

104506-02

Orifice-37"

1

 

104506-04

Orifice-41"

1

27

104507-01

Brass Elbow

1

28

104508-01

Brass Fitting

2

29

104509-01

Aluminum Tubing Assy

1

30

104510-01

Pilot Tubing Assy

1

31

101628-04

Flexible Connector

1

32

104514-01

Wall Switch

1

 

 

 

 

KEY

 

 

 

NO.

PART NUMBER

DESCRIPTION

QTY.

 

 

 

 

33

104515-01

Wire for Wall Switch

1

34

104516-01

Log Set - 37"

1

 

104561-01

Log Set - 41"

1

34-1

104876-02

Rear Log - 37"

1

 

104876-01

Rear Log - 41"

1

34-2

104877-02

Front Log - 37"

1

 

104877-01

Front Log - 41"

1

34-3

104878-02

Crossover Log - 37"

1

 

104878-01

Crossover Log - 41"

1

34-4

104879-02

Log Piece - 37"

1

 

104879-01

Log Piece - 41"

1

35

M10908-2

Screw

6

36

M12461-73

Screw

3

37

H5C4-20B

Bolt

2

38

NTC-4C

Locknut

2

39

M12461-26

Screw

4

40

104555-02CJ

Grate Assembly - 37"

1

 

104555-01CJ

Grate Assembly - 41"

1

41

105775-03

Glass Door Assy - 37"

1

 

105775-01

Glass Door Assy - 41"

1

42

NPC 1C

Nut

2

43

104576-02CK

Front Assembly - 37"

1

 

104576-03CK

Front Assembly - 41"

1

44

104615-02

Insulation - 37"

1

 

105628-01

Insulation - 41"

1

45

104313-01

Hinge, Pin

1

46

104313-02

Hinge, Pin

1

47

104954-01

Screw

3

48

104963-01

Washer

3

49

104955-01

Nut

3

50

103769-01

Duplex Outlet

1

51

104602-01

Duplex Outlet Cover

1

52

105325-01

Burner Baffle

1

 

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

 

GA6060

Lava Rock

1

 

104529-01

Ember Material

1

 

104512-01

Ball Valve

1

 

 

 

 

105539

37

Image 37
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyBDV41N/PA,B, and DDV41N/PA,B DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for VERTI- CAL TerminationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Vertical Rigid Venting Configuration Using Two 90 ElbowsParts Lists for Venting Kits and Components High Altitude InstallationVanguard Rigid Venting Vanguard Flexible VentingInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3700/DA3610T Blowers Check GAS TypeSide View As a freestanding unit with an acInstallation Items Needed Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsClose manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsAttaching Magnetic Decorative Brass Strips DDV Only REMOVING/REPLACING Glass DoorInstalling Left Side Brick Panel Installing Optional Brick Liner D8037A/D8041Fireplace Models BDV37N/PA, B Installing LOGS, Lava Rock and Glowing EmbersFireplace Models DDV37N/PA, B DDV41N/PA, B Installing Log Assembly NoManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsPilot Assembly Operating Optional Blower AccessoryInspecting Burners Optional Remote OperationGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementWiring Diagram Replacement PartsTechnical Service Service HintsBDV/DDV37NA,B BDV/DDV37PA,B BDV/DDV41NA,B BDV/DDV41PA,B SpecificationsManual Blower KIT GA3700 AccessoriesCabinet Mantel with Square LEG Styling Brass Louver KIT Brick LinerBDV37NA,B BDV41NA,B Illustrated Parts BreakdownDIRECT-VENT Fireplace BDV37NA,B BDV41NA,B Parts ListBDV37PA,B BDV41PA,B DIRECT-VENT Fireplace BDV37PA,B BDV41PA,B DDV37NA,B DDV41NA,B DIRECT-VENT Fireplace DDV37NA,B DDV41NA,B DDV37PA,B DIRECT-VENT Fireplace DDV37PA,B DDV41PA,B Warranty Information

DDV41N/P, BDV37N/P, BDV41N/P, B), DDV37N/P specifications

Desa B), DDV41N/P, DDV37N/P, BDV37N/P, and BDV41N/P represent a family of advanced heating, ventilation, and air conditioning (HVAC) systems. These models are designed to provide efficient climate control in both residential and commercial environments. They incorporate state-of-the-art technology and superior engineering, offering an optimal combination of performance, energy efficiency, and user comfort.

One of the main features of these units is their enhanced energy efficiency. Each model is built with high-efficiency compressors and advanced heat exchange technology that significantly reduces energy consumption compared to traditional HVAC systems. This not only lowers utility bills but also minimizes the environmental impact by reducing greenhouse gas emissions.

The DDV and BDV series are equipped with cutting-edge inverter technology. This allows the units to adjust their cooling and heating output in response to changing indoor conditions. Consequently, they maintain a consistent temperature while consuming less energy. This inverter-driven operation translates into quieter performance and longer lifespan for the systems, as they experience less wear and tear.

The Desa B) series, along with the DDV41N/P and DDV37N/P, features advanced filtration systems that improve indoor air quality. These filters effectively capture dust, allergens, and other airborne pollutants, making them ideal for households with allergy sufferers or for commercial spaces requiring a clean environment. Furthermore, the user-friendly interfaces and remote control options make operation convenient for users, allowing for easy temperature adjustments and system monitoring.

The BDV37N/P and BDV41N/P models stand out with their versatile installation options. They can be configured for ducted, ductless, or multi-zone systems, making them adaptable to various architectural layouts and design preferences. This flexibility ensures that they can provide the perfect solution for any space, whether it's a compact apartment or a sprawling office building.

Additionally, these models are designed with durability in mind, utilizing high-quality materials that withstand various environmental conditions. They come with robust warranties, ensuring peace of mind for users. With their combination of energy efficiency, advanced technology, and user-friendly features, the Desa B), DDV41N/P, DDV37N/P, BDV37N/P, and BDV41N/P HVAC systems are an excellent choice for anyone seeking optimal climate control solutions. Whether for residential or commercial use, these units deliver comfort and reliability, marking a significant advancement in HVAC technology.