Desa BDV41N/P, BDV37N/P, DDV37N/P, B) Horizontal Termination Configurations, Horizontal Venting

Page 10

®

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

VENTING INSTALLATION

Continued

Horizontal Termination

Configurations

Figures 17 through 21 show different con- figurations for venting with horizontal ter- mination. Each figure includes a chart with vertical minimum/maximum and horizon- tal maximum dimensions which must be met. Seal all connections with high tem- perature silicone sealant (outer pipe only) as specified in the second warning statement on page 7. All horizontal terminations re- quire 1/4" rise per 12" of horizontal run.

Horizontal Venting

Vertical (V)

UP

Horizontal (H)

44" min.

29" max.

(30° and 90° only, no vertical pipe)

55" min.

41" max.

(30° elbow, 1' vertical pipe, 90° elbow)

67" min.

60" max.

79" min.

84" max.

96" min.

20' max.

Note: This configuration for use with

corner installation.

BVK Vent Kit Shown

Figure 18 - Horizontal Termination Configuration for Rigid Venting Using One 90° Elbow

UP

GFVK Vent Kit Shown (recommended for use with cabinet mantels)

Horizontal Venting

Vertical (V)

Horizontal (H)

37" min.

17" max.

Figure 17 - Horizontal Termination Con- figuration for Rigid Venting

Horizontal Venting

See information in Figure 18 for Vertical(V) and Horizontal(H) maximums and minimums. The same amounts apply for flexible venting.

Note: Figure 17 applies to rigid venting only.

UP

BFGFVK and FGFVK Vent Kits Shown

Figure 19 - Horizontal Termination Using Flexible Venting

10

105539

Image 10
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyBDV41N/PA,B, and DDV41N/PA,B Safety Information DIRECT-VENT Fireplace NATURAL/PROPANE/LPLocal Codes Product FeaturesProduct Identification Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingPRE-INSTALLATION Preparation General Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Flat Ceiling Installation Installation for VERTI- CAL TerminationCathedral Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Rigid Venting Configuration Using Two 90 Elbows Vertical VentingVanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Vanguard Flexible VentingInstalling GA3700/DA3610T Blowers Fireplace InstallationInstalling Optional Blower Accessory Check GAS TypeAs a freestanding unit with an ac Side ViewInstalling GAS Piping to Fireplace Location Installation Items NeededPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Close manual shutoff valve see Fig- ureREMOVING/REPLACING Glass Door Attaching Magnetic Decorative Brass Strips DDV OnlyInstalling Optional Brick Liner D8037A/D8041 Installing Left Side Brick PanelInstalling LOGS, Lava Rock and Glowing Embers Fireplace Models BDV37N/PA, BInstalling Log Assembly No Fireplace Models DDV37N/PA, B DDV41N/PA, BOperating Fireplace For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsInspecting Burners Operating Optional Blower AccessoryPilot Assembly Optional Remote OperationPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveTechnical Service Replacement PartsWiring Diagram Service HintsSpecifications BDV/DDV37NA,B BDV/DDV37PA,B BDV/DDV41NA,B BDV/DDV41PA,BCabinet Mantel with Square LEG Styling Brass Louver KIT AccessoriesManual Blower KIT GA3700 Brick LinerIllustrated Parts Breakdown BDV37NA,B BDV41NA,BParts List DIRECT-VENT Fireplace BDV37NA,B BDV41NA,BBDV37PA,B BDV41PA,B DIRECT-VENT Fireplace BDV37PA,B BDV41PA,B DDV37NA,B DDV41NA,B DIRECT-VENT Fireplace DDV37NA,B DDV41NA,B DDV37PA,B DIRECT-VENT Fireplace DDV37PA,B DDV41PA,B Warranty Information

DDV41N/P, BDV37N/P, BDV41N/P, B), DDV37N/P specifications

Desa B), DDV41N/P, DDV37N/P, BDV37N/P, and BDV41N/P represent a family of advanced heating, ventilation, and air conditioning (HVAC) systems. These models are designed to provide efficient climate control in both residential and commercial environments. They incorporate state-of-the-art technology and superior engineering, offering an optimal combination of performance, energy efficiency, and user comfort.

One of the main features of these units is their enhanced energy efficiency. Each model is built with high-efficiency compressors and advanced heat exchange technology that significantly reduces energy consumption compared to traditional HVAC systems. This not only lowers utility bills but also minimizes the environmental impact by reducing greenhouse gas emissions.

The DDV and BDV series are equipped with cutting-edge inverter technology. This allows the units to adjust their cooling and heating output in response to changing indoor conditions. Consequently, they maintain a consistent temperature while consuming less energy. This inverter-driven operation translates into quieter performance and longer lifespan for the systems, as they experience less wear and tear.

The Desa B) series, along with the DDV41N/P and DDV37N/P, features advanced filtration systems that improve indoor air quality. These filters effectively capture dust, allergens, and other airborne pollutants, making them ideal for households with allergy sufferers or for commercial spaces requiring a clean environment. Furthermore, the user-friendly interfaces and remote control options make operation convenient for users, allowing for easy temperature adjustments and system monitoring.

The BDV37N/P and BDV41N/P models stand out with their versatile installation options. They can be configured for ducted, ductless, or multi-zone systems, making them adaptable to various architectural layouts and design preferences. This flexibility ensures that they can provide the perfect solution for any space, whether it's a compact apartment or a sprawling office building.

Additionally, these models are designed with durability in mind, utilizing high-quality materials that withstand various environmental conditions. They come with robust warranties, ensuring peace of mind for users. With their combination of energy efficiency, advanced technology, and user-friendly features, the Desa B), DDV41N/P, DDV37N/P, BDV37N/P, and BDV41N/P HVAC systems are an excellent choice for anyone seeking optimal climate control solutions. Whether for residential or commercial use, these units deliver comfort and reliability, marking a significant advancement in HVAC technology.