Desa CD36M, CD32M, CD42M, CD42M (-A)(-A2) Burner Flame Adjustment, Decorative Facing

Page 11

INSTALLATION

Installing Log Set (Cont.) Decorative Facing Face Extension for Model DC32M Only

BURNER FLAME ADJUSTMENT

11

INSTALLATION

Continued

Lava Rock and Ember Material

1. For all models, place lava rock along sides and front of firebox bottom in areas that are visible. It is not necessary to use all lava rock provided.

NOTICE: Do not put lava rock on or under burner. Placing lava rock on burner could cause perfor- mance problems.

2.Pull ember material apart into pieces no larger than a dime. Place

loosely and directly onto exposed section of front burner and along space between burner and grate prongs. These will create glowing ember appearance as flame touches ember material. Do not block air slots by using too much ember material in one area. It is not necessary to use all ember material provided.

3.When lava rock and ember material are in place, close and latch glass door and secure louvers in place.

WARNING: The glass door must be securely in place before operating fireplace. Do not operate fire- place if glass is missing or broken.

DECORATIVE FACING

 

Any noncombustible material may be used as facing (glass, tile,

 

brick, etc.) as long as the proper clearances are observed (see

 

Clearances to Combustibles, page 3). Louvered openings must not

 

be obstructed and upper and lower panels must remain accessible

 

for service. Use only heat-resistant, noncombustible mortar or

Figure 29 - Front Face Extension, Model CD32M Only

adhesive when securing decorative facing materials.

FACE EXTENSION FOR MODEL CD32M ONLY

Model CD32M comes equipped with a front face extension. The front face extension would add 3 1/2" to the width and 3/4" to the height of the fireplace face.

To install face extension:

1.Remove existing screws from front face assembly as shown in Figure 29.

2.Align holes on top face extension with holes on top side of front face assembly and secure with screws previously removed (see Figure 29).

3.Align holes on right face extension with holes on right side of front face assembly and secure with screws previously removed (see Figure 29). Do the same for left side.

4.Secure top face extension with left and right face extensions with two sheet metal screws (see Figure 29).

BURNER FLAME ADJUSTMENT

The burner flame adjustment (shutter opening) has been factory preset (for natural gas) to the proper air-to-gas ratio. This ratio results in an even, clean burning flame across the burner (see Figure 30).

CORRECT Long, Blue Flame with Yellow Tips

INCORRECT

CLOSE SHUTTER

Short, Sharp, Blowing Flame

INCORRECT

OPEN SHUTTER

Long, Uneven, Yellow Flame

Figure 30 - Burner Flame Patterns

For..com

111916-01D

Image 11
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Introduction Table of ContentsMantel Clearances PRE-INSTALLATION PreparationSelecting Location Clearances to CombustiblesFraming Vent Termination ClearancesMinimum Clearances for Vent Terminations Venting Installation InstallationVenting Installation Precautions Electrical Hookup and Remote Receiver Diagram GAS Supply TestingGAS Line HOOK-UP Pilot AdjustmentRemoving Glass Panel Installing LOG SETModel CD42M-A Series Face Extension for Model CD32M only Burner Flame AdjustmentDecorative Facing Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Operation GuidelinesTo Turn OFF GAS To Appliance Converting Fireplace from Natural GAS to PROPANE/LP GASConverting Pilot Converting Control Valve Installing New Parts for Gas Control Valve ConversionObserved Problem Possible Cause Remedy TroubleshootingCD36M-A Series Illustrated Parts BreakdownModels CD32M Models CD32M CD36M-A Series Parts ListModel CD42M-A Not a field replaceable part Wiring Diagram SpecificationsMillivolt Accessory and Replacement PartsNot a UPC