TROUBLESHOOTING
TROUBLESHOOTING
WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
15
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
Pilot will not stay lit | 1. | Defective thermocouple | 1. | Check pilot flame. It must impinge on |
|
|
|
| thermocouple |
|
|
| 2. | Clean or adjust pilot for maximum flame |
|
|
|
| impingement on thermocouple |
|
|
| 3. | Ensure the connection between valve |
|
|
|
| and thermocouple are tight and secure |
|
|
| 4. | Check thermocouple with millivolt |
|
|
|
| meter. Take reading at thermocouple ter- |
|
|
|
| minals of gas valve with remote control |
|
|
|
| off. It should read 18 millivolts mini- |
|
|
|
| mum. Replace faulty thermocouple if |
|
|
|
| reading is below specified minimum |
|
|
|
|
|
Pilot lit but no flame on burner | 1. | Remote or wires defective | 1. | Check remote wires for proper connec- |
|
|
|
| tions. Place jumper wire across termi- |
|
|
|
| nals at remote control. If burner comes |
|
|
|
| on, replace remote. If okay, place jumper |
|
|
|
| wire across remote control at valve. If |
|
|
|
| burner comes on, wires are faulty or con- |
|
|
|
| nections are bad |
| 2. | Thermopile not generating sufficient | 2. | Check thermopile with millivolt meter. |
|
| milivoltage |
| Take reading at thermopile terminals of |
|
|
|
| gas valve with remote control off. It |
|
|
|
| should read 325 millivolts minimum. |
|
|
|
| Replace thermopile if reading is below |
|
|
|
| specified minimum |
| 3. | Plugged burner orifice | 3. | Check burner orifice for stoppage and |
|
|
|
| remove |
Frequent pilot outage | 1. Pilot flame may be too low or blowing |
| (high) causing safety pilot to “drop out” |
1.Clean and/or adjust pilot flame for maximum flame impingement on thermocouple
For..com