Desa CD36M, CD32M, CD42M, CD42M (-A)(-A2) Removing Glass Panel, Installing LOG SET

Page 9

INSTALLATION

Removing Glass Panel Installin Log Set

9

INSTALLATION

Continued

REMOVING GLASS PANEL

CAUTION: Before you proceed, make sure your gas control valve is in the OFF position.

1.To remove louvers, pull both spring latches (located in each end of louver) toward center of appliance at the same time until disengaged from locating holes. Repeat for bottom end spring latches (see Figure 16).

2.Remove screen rod by removing rod loop from glass door center bracket. Slide screen rod either to the left or right of fireplace until one end is free to completely remove screen from fireplace.

3.Undo latches located on top and bottom of firebox (see Figure 17). Carefully swing door to the left. The glass door is se- curely mounted to the firebox with 5 screws.

Glass

Locating

Holes

Bottom

LouverSpring

Latch

Figure 16 - Removing Louvers

Open

Close

Figure 17 - Spring Latches

INSTALLING LOG SET

Each log is marked with a number in the following diagram. These numbers will help in identifying the logs when installed. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with fireplace.

Models CD32M and CD36M-A Series

1.Place log #1 (back log) on top of grate as shown in Figure 18 for the CD36M-A Series. Log #1 will go in front of the metal partition on grate (see Figure 18). Make sure notches in bot- tom of log fit over grate.

2.Place log #2 (large front log) over pins on grate (see Figure 19).

3.Place log #3 (c-shaped crossover log) onto rear and front logs as shown in Figure 20. Make sure it is seated properly on the smooth surface on front log and on the pin on back log.

4.Place log #4 (small round log) on pin on right side of front log (see Figure 21).

5.Place log #5 (small front log) onto the front left part of grate making sure notches fit over prongs of grate (see Figure 22).

6.Place log #6 onto two pins on left side of back and front logs (see Figure 22).

CD32M

 

 

Log #1

1

2

Placement

 

 

 

Figure 18 - Installing Log #1

Figure 19 - Installing Log #2

(CD36M-A Series Shown)

(CD36M-A Series Shown)

3

4

Figure 20 - Installing Log #3

Figure 21 - Installing Log #4

(CD36M-A Series Shown)

(CD36M-A Series Shown)

6

 

5

 

Figure 22 - Installing Logs #5 and #6 (CD36M-A Series Shown)

For..com

111916-01D

Image 9
Contents OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Introduction Table of ContentsSelecting Location PRE-INSTALLATION PreparationClearances to Combustibles Mantel ClearancesFraming Vent Termination ClearancesMinimum Clearances for Vent Terminations Installation Venting Installation PrecautionsVenting Installation Electrical Hookup and Remote Receiver Diagram GAS Supply TestingGAS Line HOOK-UP Pilot AdjustmentRemoving Glass Panel Installing LOG SETModel CD42M-A Series Burner Flame Adjustment Decorative FacingFace Extension for Model CD32M only Operating Fireplace For Your Safety Read Before LightingOperation Guidelines Lighting InstructionsConverting Fireplace from Natural GAS to PROPANE/LP GAS Converting PilotTo Turn OFF GAS To Appliance Converting Control Valve Installing New Parts for Gas Control Valve ConversionObserved Problem Possible Cause Remedy TroubleshootingIllustrated Parts Breakdown Models CD32MCD36M-A Series Models CD32M CD36M-A Series Parts ListModel CD42M-A Not a field replaceable part Wiring Diagram SpecificationsMillivolt Accessory and Replacement PartsNot a UPC