Desa CD36M, CD32M, CD42M, CD42M (-A)(-A2) Converting Fireplace from Natural GAS to PROPANE/LP GAS

Page 13

OPERATING FIREPLACE

Lighting Instructions (Con.)

To Turn Off Gas To Appliance

CONVERTING FIREPLACE FROM NATURAL GAS TO PROPANE/LP GAS

13

OPERATING FIREPLACE

Continued

9.Push in the control knob all the way and hold in. Immedi- ately light the pilot by pressing the red ignitor button until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.

If knob does not pop out when released, stop and call service technician or gas supplier.

If the pilot will not stay lit after several tries, turn gas control knob to “OFF” and call your service technician or gas supplier.

10.Turn gas control knob counterclockwise to “ON”. Knob can be turned to “ON” only if the control knob is popped out.

11.Set “HI-LO” knob to desired setting.

12.Turn on all electric power to the appliance.

Note: It is recommended that you maintain the gas control knob in the full OFF position during lengthy periods of seasonal non-usage.

HI/LO Knob

Position Indicator

 

 

 

O

 

 

 

 

 

IL

T

 

 

 

 

 

P

 

 

 

 

N

 

16AI

 

 

 

 

O

 

 

 

 

O

T

 

 

 

TH

 

 

 

 

7

 

I

 

 

 

L

 

 

 

 

 

P

L

I

 

 

 

 

 

 

 

 

 

FFO

O

H

 

TP

 

 

 

 

 

 

Gas Control Knob

 

E

A

 

 

TPTH

 

 

 

 

Figure 32 - Control Knob in Pilot Position

 

 

Piezo Ignitor

 

 

 

Pilot Burner

 

Thermocouple

 

 

 

Thermopile

Figure 33 - Pilot

CONVERTING FIREPLACE FROM NATURAL GAS TO PROPANE/LP GAS

The conversion kit is packaged with the unit. Please check the contents before beginning this conversion.

WARNING: Before proceeding, make sure the gas control valve is in the OFF position and all electrical power to the appliance is turned off.

CONVERTING PILOT

1.Wait five (5) minutes to clear out any gas. Smell for any gas odor, especially near the floor. If any gas odor is present, STOP! See For Your Safety Read Before Lighting on page 12.

2.Locate the latch on the louver assembly. Remove top and bottom louvers by pulling the spring latches toward the cen- ter of the fireplace simultaneously until they are diengaged from the locating holes.

3.Undo latches located on top and bottom of firebox and swing door to the fully open position.

4.Carefully remove log set and ember material from burner and place them aside in a safe place.

5.Replace main burner orifice with burner orifice included in conversion kit (Model CD42M-A series contains two burner orifices).

6.Locate air shutter at end of burner manifold (end of tube burner for CD42M series). Loosen screw and adjust air shutter to proper setting (see Burner Flame Adjustment, page 11). Re- tighten screw.

7.Remove pilot hood by pulling up until it disengages from bar- rel. Do not remove the retainer clip (see Figure 34).

8.Remove pilot orifice from inside barrel using a 5/32" allen wrench to unscrew the orifice.

9.Replace pilot orifice with LP orifice supplied with this kit. The number 30 is stamped on the sleeve for identification. Insert small end of new pilot orifice into barrel and thread until tight with the allen wrench.

TO TURN OFF GAS

TO APPLIANCE

1.Turn off the wall switch.

2.Turn off all electric power to the appliance if service is to be performed.

3.Remove control access panel.

4.Push in gas control knob slightly and turn clockwise to “OFF”. Do not force.

5.Replace control access panel.

Pilot Hood

Pilot Orifice

Barrel Clip

5/32" Allen Wrench

Pilot Bracket

Figure 34 - Converting Pilot

For..com

111916-01D

Image 13
Contents For Your Safety OWNER’S Operation Installation ManualFor Your Safety What to do if YOU Smell GAS Introduction Table of ContentsSelecting Location PRE-INSTALLATION PreparationClearances to Combustibles Mantel ClearancesFraming Vent Termination ClearancesMinimum Clearances for Vent Terminations Venting Installation Precautions InstallationVenting Installation Electrical Hookup and Remote Receiver Diagram GAS Supply TestingGAS Line HOOK-UP Pilot AdjustmentRemoving Glass Panel Installing LOG SETModel CD42M-A Series Decorative Facing Burner Flame AdjustmentFace Extension for Model CD32M only Operating Fireplace For Your Safety Read Before LightingOperation Guidelines Lighting InstructionsConverting Pilot Converting Fireplace from Natural GAS to PROPANE/LP GASTo Turn OFF GAS To Appliance Converting Control Valve Installing New Parts for Gas Control Valve ConversionObserved Problem Possible Cause Remedy TroubleshootingModels CD32M Illustrated Parts BreakdownCD36M-A Series Models CD32M CD36M-A Series Parts ListModel CD42M-A Not a field replaceable part Wiring Diagram SpecificationsMillivolt Accessory and Replacement PartsNot a UPC