Desa CHDV34(N/P)(A) Vertical Termination Configurations, Venting with One 90 Elbow

Page 13

OWNER’S MANUAL

VENTING INSTALLATION

Continued

3.Lower the support box through the hole in the roof until the bottom of the box extends at least 2" below the ceiling (see Figure 23). Align the support box vertically and horizontally using a level. Temporarily tack the support box in place through the inside walls and into the roof sheathing.

4.Using tin snips, cut the support box from the top corners down to the roofline and fold the resulting flaps over the roof sheathing (see Figure 24). Apply a bead of non-hardening mastic around the top edges of the support box to make a seal between the box and the roof. Nail in place with roofing nails. Remove any combustible material that might be in- side of the support box.

5.Complete the cathedral ceiling instal- lation by following the same proce- dures outlined in steps 2 through 7 for Flat Ceiling Installation, page 12.

Level

Cathedral ceiling support box

2" minimum below finished ceiling

Vertical Termination Configurations

Figures 25 through 28 show four different configurations for vertical termination. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 7.

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H1) +

 

Horizontal (H2)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

Note: Install restrictor into 4" collar of stove as shown.

Figure 25 - Vertical Rigid Venting Configuration Using Two 90° Elbows with Two

Horizontal Runs

Cut hole 1/8" larger than support box when projected onto roofline

Figure 23 - Cathedral Ceiling Support Box Installation

Note: Install restrictor into 4" collar of stove as shown.

Venting with One 90° Elbow

Vertical (V)

Horizontal (H)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

Non-hardening Mastic under all edges of support box before nailing

Figure 24 - Installed Cathedral Ceiling

Figure 26 - Vertical Rigid Venting Configuration Using One 90° Elbow

 

Support Box

Continued

105456

13

Image 13
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyDIRECT-VENT Fireplace NATURAL/PROPANE Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingLocation of Vent Termination General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsParts Lists for Venting Kits and Components High Altitude InstallationComfort Glow Rigid Venting Number DescriptionSimpson Dura-Vent GS 4 x 6 5/8 Comfort Glow Flexible VentingNumber Description Available from Desa International Available from Simpson Dura-Vent OnlyInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3750/CDA3620T Blowers Check GAS TypePlug in blower power cord Installation Items Needed Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsInstalling 9-Volt Battery in Hand- Held Remote Control Unit Installing Remote ReceiverREMOVING/REPLACING Glass Door Installing Rear Brick Panel and Retainer Brackets Installing Optional Brick Liner CD8037Fireplace Model CHDV34N/PA Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsThermostat Control Operation Optional Remote OperationCghrc Operation Cghrct OperationPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementWiring Diagram Replacement PartsTechnical Service Service HintsCHDV34NA Illustrated Parts BreakdownDIRECT-VENT Fireplace CHDV34NA Parts ListCHDV34PA DIRECT-VENT Fireplace CHDV34PA Accessories 105456 Warranty Information

CHDV34(N/P)(A) specifications

Desa CHDV34(N/P)(A) is a state-of-the-art heating solution designed to address the modern needs of both residential and commercial spaces. This system is distinguished by its innovative design, efficiency, and reliability, making it a top choice for users seeking an effective climate control solution.

One of its main features is the advanced heat exchange technology employed in the unit. The system utilizes a high-efficiency heat exchanger to increase thermal efficiency, ensuring that a minimal amount of energy is wasted during the heating process. This feature not only helps reduce energy consumption but also contributes to lower utility bills over time, making it an environmentally friendly choice.

Another significant characteristic of the Desa CHDV34(N/P)(A) is its versatility in installation. The unit can be installed in various locations, including ceilings, walls, or floors, affording users the flexibility to optimize space usage. This adaptability makes it suitable for a wide range of applications, from small homes to larger commercial settings, tailoring to the unique requirements of each space.

Technologically, the Desa CHDV34(N/P)(A) is equipped with smart features that enhance its usability. It includes programmable thermostats and remote control capabilities that allow users to adjust settings conveniently from a distance. This feature not only adds comfort but also ensures that the heating system operates efficiently, reducing heating costs while maintaining a pleasant indoor environment.

Additionally, the Desa CHDV34(N/P)(A) is designed with safety in mind. It incorporates multiple safety features, including overheat protection and automatic shut-off systems, ensuring secure operation even under prolonged usage. This commitment to safety contributes to user peace of mind, knowing that they are using a reliable heating solution.

In conclusion, Desa CHDV34(N/P)(A) stands out for its efficiency, versatility, and technological advancements. It is an ideal choice for users looking to enhance their comfort while minimizing environmental impact and operational costs. With its innovative features and robust safety measures, it encapsulates what modern heating solutions should offer, positioning itself as a frontrunner in the market.