Desa CHDV34(N/P)(A) Cleaning and Maintenance, Glass Door, Pilot and Burners, Logs, Venting System

Page 27

OWNER’S MANUAL

CLEANING AND MAINTENANCE

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep con- trol areas, burners, and circulat- ing air passageways of fireplace clean. Inspect these areas of fire- place before each use. Have fire- place inspected yearly by a quali- fied service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

GLASS DOOR

WARNING: Handle glass door panel with care. Do not strike, slam or otherwise abuse glass. Do not operate fireplace with the glass door removed, cracked, or broken.

WARNING: Do not use abra- sive cleaners as this may damage glass. Use a non-abrasive house- hold glass cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-amonia, non- abrasive household cleaner and warm water after the first two weeks of operation. There- after, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door on page 21 of this manual when removing glass door for cleaning.

WARNING: Only parts sup- plied by the manufacturer should be used when replacing broken or damaged glass door panel (see Replacement Parts, page 31). This glass door panel is a complete unit. No substitute materials may be used.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep chil- dren and pets away from glass.

If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 21). Vacuum all glass pieces with a shop vac.

CAUTION: Do not vacuum if pieces are hot.

Use only the ceramic glass door replace- ment intended for this fireplace (see Re- placement Parts, page 31 for detail on or- dering). No substitutions may be made. See Removing/Replacing Glass Door, page 21 for instructions for replacing glass door.

WARNING: Do not operate fireplace with the glass door re- moved, cracked, or broken.

PILOT AND BURNERS

Remove ember material before cleaning burners and replace when cleaning is complete.

Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint.

LOGS

If you remove logs for cleaning, refer to Installing Logs, Lava Rock, and Glowing Embers, page 23, to properly replace logs.

Use a vacuum cleaner to remove any car- bon build-up on logs.

Replace log(s) if broken. See Replace- ment Parts on page 31.

Replace ember material periodically as needed. See Replacement Parts on page 31.

VENTING SYSTEM

Conduct annual inspection of the venting system following these guidelines:

1.Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced imme- diately by a qualified service person.

2.Remove the vent cap and shine a flash- light into the vent. Remove any foreign material.

3.Check for evidence of excessive con- densation. Continuous condensation can cause corrosion of caps, pipes, and fittings and can be caused by having excessive lateral runs, too many el- bows, or exterior portions of the sys- tem being exposed to cold weather.

4.Inspect joints to verify that no pipe sec- tion or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.

105456

27

Image 27
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyDIRECT-VENT Fireplace NATURAL/PROPANE Safety InformationGlossary Terms Product FeaturesProduct Identification Local CodesFraming and Finishing PRE-INSTALLATION PreparationLocation and Space Requirements ClearancesLocation of Vent Termination General VentingGeneral Venting Installing Vent System in a Chase Venting InstallationInstallation Precautions Installation PlanningSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsNumber Description High Altitude InstallationParts Lists for Venting Kits and Components Comfort Glow Rigid VentingAvailable from Simpson Dura-Vent Only Comfort Glow Flexible VentingSimpson Dura-Vent GS 4 x 6 5/8 Number Description Available from Desa InternationalCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessory Installing GA3750/CDA3620T BlowersPlug in blower power cord Installation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsInstalling Remote Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitREMOVING/REPLACING Glass Door Installing Rear Brick Panel and Retainer Brackets Installing Optional Brick Liner CD8037Fireplace Model CHDV34N/PA Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceCghrct Operation Optional Remote OperationThermostat Control Operation Cghrc OperationOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementService Hints Replacement PartsWiring Diagram Technical ServiceCHDV34NA Illustrated Parts BreakdownDIRECT-VENT Fireplace CHDV34NA Parts ListCHDV34PA DIRECT-VENT Fireplace CHDV34PA Accessories 105456 Warranty Information

CHDV34(N/P)(A) specifications

Desa CHDV34(N/P)(A) is a state-of-the-art heating solution designed to address the modern needs of both residential and commercial spaces. This system is distinguished by its innovative design, efficiency, and reliability, making it a top choice for users seeking an effective climate control solution.

One of its main features is the advanced heat exchange technology employed in the unit. The system utilizes a high-efficiency heat exchanger to increase thermal efficiency, ensuring that a minimal amount of energy is wasted during the heating process. This feature not only helps reduce energy consumption but also contributes to lower utility bills over time, making it an environmentally friendly choice.

Another significant characteristic of the Desa CHDV34(N/P)(A) is its versatility in installation. The unit can be installed in various locations, including ceilings, walls, or floors, affording users the flexibility to optimize space usage. This adaptability makes it suitable for a wide range of applications, from small homes to larger commercial settings, tailoring to the unique requirements of each space.

Technologically, the Desa CHDV34(N/P)(A) is equipped with smart features that enhance its usability. It includes programmable thermostats and remote control capabilities that allow users to adjust settings conveniently from a distance. This feature not only adds comfort but also ensures that the heating system operates efficiently, reducing heating costs while maintaining a pleasant indoor environment.

Additionally, the Desa CHDV34(N/P)(A) is designed with safety in mind. It incorporates multiple safety features, including overheat protection and automatic shut-off systems, ensuring secure operation even under prolonged usage. This commitment to safety contributes to user peace of mind, knowing that they are using a reliable heating solution.

In conclusion, Desa CHDV34(N/P)(A) stands out for its efficiency, versatility, and technological advancements. It is an ideal choice for users looking to enhance their comfort while minimizing environmental impact and operational costs. With its innovative features and robust safety measures, it encapsulates what modern heating solutions should offer, positioning itself as a frontrunner in the market.