Desa CHDV34(N/P)(A) installation manual Installing Optional Brick Liner CD8037

Page 22

CHDV34(N/P)(A)

DIRECT-VENT FIREPLACE (NATURAL/PROPANE)

FIREPLACE INSTALLATION

Continued

INSTALLING OPTIONAL BRICK LINER CD8037

WARNING: If fireplace has been running, turn off and un- plug fireplace. Let cool before installing brick liner.

This brick liner kit is optional. You may purchase brick liner from your local retailer or see Accessories, page 36.

CAUTION: Always handle brick panels with two hands. Do not force brick panels into place. Excessive force will break brick panels.

1.Remove glass door. See Removing/Re- placing Glass Door, page 21.

2.If installing brick liner in new fireplace, go to step 3. If installing brick liner in an existing fireplace, carefully remove logs, lava rock, and ember material.

3.Install rear brick panel first. Rest bot- tom edge of panel on back edge of grate (see Figure 46).

4.Loosely secure retainer brackets to grate. Brackets are adjustable left to right to allow proper placement of panel. These will hold rear panel in place while installing side panels.

5.Install left side brick panel by sliding it between the grate and the side of the firebox (see Figure 47).

6.Slide the left retainer bracket against the left side brick panel. Tighten the bracket screw. This secures both the left side and rear brick panels.

7.Install the right brick panel using the same method described in step 5.

8.Slide the right retainer bracket against the right side brick panel. Tighten the bracket screw. This secures both the right side and rear brick panels.

9.Follow instructions on page 23 to install logs, lava rock, and ember material.

10.Replace glass door (see page 21).

Rear Brick Panel

Retaining Brackets

Figure 46 - Installing Rear Brick Panel and Retainer Brackets

Left Side

Brick Panel

Retainer

Brackets

Figure 47 - Installing Left Side Brick Panel

22

105456

Image 22
Contents For Your Safety For Your Safety What to do if YOU Smell GASSafety Information DIRECT-VENT Fireplace NATURAL/PROPANELocal Codes Product FeaturesProduct Identification Glossary TermsClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingGeneral Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowComfort Glow Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Number DescriptionNumber Description Available from Desa International Comfort Glow Flexible VentingSimpson Dura-Vent GS 4 x 6 5/8 Available from Simpson Dura-Vent OnlyInstalling GA3750/CDA3620T Blowers Fireplace InstallationInstalling Optional Blower Accessory Check GAS TypePlug in blower power cord Installing GAS Piping to Fireplace Location Installation Items NeededPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling 9-Volt Battery in Hand- Held Remote Control Unit Installing Remote ReceiverREMOVING/REPLACING Glass Door Installing Optional Brick Liner CD8037 Installing Rear Brick Panel and Retainer BracketsInstalling LOGS, Lava Rock and Glowing Embers Fireplace Model CHDV34N/PAOperating Fireplace For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsCghrc Operation Optional Remote OperationThermostat Control Operation Cghrct OperationInspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveTechnical Service Replacement PartsWiring Diagram Service HintsIllustrated Parts Breakdown CHDV34NAParts List DIRECT-VENT Fireplace CHDV34NACHDV34PA DIRECT-VENT Fireplace CHDV34PA Accessories 105456 Warranty Information

CHDV34(N/P)(A) specifications

Desa CHDV34(N/P)(A) is a state-of-the-art heating solution designed to address the modern needs of both residential and commercial spaces. This system is distinguished by its innovative design, efficiency, and reliability, making it a top choice for users seeking an effective climate control solution.

One of its main features is the advanced heat exchange technology employed in the unit. The system utilizes a high-efficiency heat exchanger to increase thermal efficiency, ensuring that a minimal amount of energy is wasted during the heating process. This feature not only helps reduce energy consumption but also contributes to lower utility bills over time, making it an environmentally friendly choice.

Another significant characteristic of the Desa CHDV34(N/P)(A) is its versatility in installation. The unit can be installed in various locations, including ceilings, walls, or floors, affording users the flexibility to optimize space usage. This adaptability makes it suitable for a wide range of applications, from small homes to larger commercial settings, tailoring to the unique requirements of each space.

Technologically, the Desa CHDV34(N/P)(A) is equipped with smart features that enhance its usability. It includes programmable thermostats and remote control capabilities that allow users to adjust settings conveniently from a distance. This feature not only adds comfort but also ensures that the heating system operates efficiently, reducing heating costs while maintaining a pleasant indoor environment.

Additionally, the Desa CHDV34(N/P)(A) is designed with safety in mind. It incorporates multiple safety features, including overheat protection and automatic shut-off systems, ensuring secure operation even under prolonged usage. This commitment to safety contributes to user peace of mind, knowing that they are using a reliable heating solution.

In conclusion, Desa CHDV34(N/P)(A) stands out for its efficiency, versatility, and technological advancements. It is an ideal choice for users looking to enhance their comfort while minimizing environmental impact and operational costs. With its innovative features and robust safety measures, it encapsulates what modern heating solutions should offer, positioning itself as a frontrunner in the market.