Desa CHDV34(N/P)(A) Optional Remote Operation, Thermostat Control Operation, Cghrc Operation

Page 25

OWNER’S MANUAL

OPERATING

FIREPLACE

Continued

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 36). Follow instructions included with the remote control.

Thermostat Control Operation

(Optional CGHRCT Only) The thermo- stat control setting on the remote control unit can be set to any comfort level be- tween HI and LO. The burners will turn on and off automatically to maintain the comfort level you select. The ideal com- fort setting will vary by household de- pending upon the amount of space to be heated, the output of the central heating system, etc.

For wall thermostat operation, follow in- struction supplied with thermostat acces- sory GWMT1.

CGHRC Operation:

2a. Press the ON/OFF button to turn the burner on and off. When turning burner off, the pilot will remain lit.

CGHRCT Operation:

2b. Select the MAN (manual) or AUTO button on the hand-held remote con- trol unit (see Figure 55).

In manual mode, turn burners on or off by pressing the ON or OFF buttons on the hand-held remote control unit.

In auto mode, the room tempera- ture is controlled by the thermo- stat in the hand-held remote con- trol unit. To increase the room tem- perature, press the top arrow of the TEMP button. To lower the room temperature, press the bottom ar- row of the TEMP button. At higher settings the heater will run more.

Blower Control Knob

Flame

(Optional Accessory)

Adjustment

 

Knob

IMPORTANT: This remote control has been specially engineered to take an air temperature sample ev- ery 5.5 minutes in the AUTO mode. It will not respond immedi- ately to the temperature setting being turned up or down.

IMPORTANT: The hand-held re- mote control unit must be near the heater. Do not keep the hand-held remote control unit too close to the heater. The thermostat on the hand-held remote control unit will heat up too quickly and turn the heater off.

3. Use the STATUS button on the hand-

held remote control unit to see the

operation mode being used and the

temperature setting selected. A red

light will come on beside the opera-

tion mode being used when the sta-

tus button is pressed.

4. To turn the burners off when operat-

ing in the manual mode, press the OFF

button. If operating in the auto mode,

press the MAN button, then press the

OFF button. The pilot will remain lit.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 24.

1. After lighting, let pilot flame burn for

about one minute. Turn control knob

OFF

ON

ON

OFF

REMOTE

Selector Switch in Remote Position

N

 

L

 

O

 

O

I

T

F

O

H

O

 

 

F

 

 

LIP

 

 

 

 

 

 

 

Control Knob in ON Position

IMPORTANT: To turn the pilot off,

manually turn the control knob on the

heater to the OFF position.

to ON position. Adjust flame adjust-

ment knob anywhere between HI

and LO. Slide the selector switch to

the REMOTE position (see Figure

54). Note: The burners may light if

Figure 54 - Setting the (CGHRCT) Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

hand-held remote ON button was on

when selector switch was last turned

off. You can now turn the burners on

and off with the hand-held remote

control unit.

IMPORTANT: Do not leave the selec-

tor switch in the REMOTE position

when the pilot is not lit. This will

drain the battery.

IMPORTANT: Be sure to press the

ON/OFF buttons on the hand-held

remote control unit for up to 3 sec-

Shows Temperature Setting

Allows Burner(s) to be Turned On and Off with the Hand- Held Remote Unit.

The Heater Will Automatically Cycle Between Pilot and the Heat Setting that has been Selected.

HI

TEMP

MAN LO ON

AUTO OFF

STATUS

Increases Room Temperature

Decreases Room Temperature

Turns Burners On and Off

Shows Current Operation Mode

onds to assure proper operation.

Figure 55 - Hand-Held Thermostat Remote Control Unit Selections (CGHRCT)

Continued

105456

25

Image 25
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyDIRECT-VENT Fireplace NATURAL/PROPANE Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingLocation of Vent Termination General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsParts Lists for Venting Kits and Components High Altitude InstallationComfort Glow Rigid Venting Number DescriptionSimpson Dura-Vent GS 4 x 6 5/8 Comfort Glow Flexible VentingNumber Description Available from Desa International Available from Simpson Dura-Vent OnlyInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3750/CDA3620T Blowers Check GAS TypePlug in blower power cord Installation Items Needed Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsInstalling 9-Volt Battery in Hand- Held Remote Control Unit Installing Remote ReceiverREMOVING/REPLACING Glass Door Installing Rear Brick Panel and Retainer Brackets Installing Optional Brick Liner CD8037Fireplace Model CHDV34N/PA Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsThermostat Control Operation Optional Remote OperationCghrc Operation Cghrct OperationPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementWiring Diagram Replacement PartsTechnical Service Service HintsCHDV34NA Illustrated Parts BreakdownDIRECT-VENT Fireplace CHDV34NA Parts ListCHDV34PA DIRECT-VENT Fireplace CHDV34PA Accessories 105456 Warranty Information

CHDV34(N/P)(A) specifications

Desa CHDV34(N/P)(A) is a state-of-the-art heating solution designed to address the modern needs of both residential and commercial spaces. This system is distinguished by its innovative design, efficiency, and reliability, making it a top choice for users seeking an effective climate control solution.

One of its main features is the advanced heat exchange technology employed in the unit. The system utilizes a high-efficiency heat exchanger to increase thermal efficiency, ensuring that a minimal amount of energy is wasted during the heating process. This feature not only helps reduce energy consumption but also contributes to lower utility bills over time, making it an environmentally friendly choice.

Another significant characteristic of the Desa CHDV34(N/P)(A) is its versatility in installation. The unit can be installed in various locations, including ceilings, walls, or floors, affording users the flexibility to optimize space usage. This adaptability makes it suitable for a wide range of applications, from small homes to larger commercial settings, tailoring to the unique requirements of each space.

Technologically, the Desa CHDV34(N/P)(A) is equipped with smart features that enhance its usability. It includes programmable thermostats and remote control capabilities that allow users to adjust settings conveniently from a distance. This feature not only adds comfort but also ensures that the heating system operates efficiently, reducing heating costs while maintaining a pleasant indoor environment.

Additionally, the Desa CHDV34(N/P)(A) is designed with safety in mind. It incorporates multiple safety features, including overheat protection and automatic shut-off systems, ensuring secure operation even under prolonged usage. This commitment to safety contributes to user peace of mind, knowing that they are using a reliable heating solution.

In conclusion, Desa CHDV34(N/P)(A) stands out for its efficiency, versatility, and technological advancements. It is an ideal choice for users looking to enhance their comfort while minimizing environmental impact and operational costs. With its innovative features and robust safety measures, it encapsulates what modern heating solutions should offer, positioning itself as a frontrunner in the market.