Desa CGCFTP, CGCFTN 14, HDCFTN Troubleshooting, Observed Problem Possible Cause Remedy

Page 23

TROUBLESHOOTING

WARNING:Turnoffand unplugfireplaceandletcoolbeforeservicing. Only a qualified service person should service and repair fireplace.

CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

When ignitor button is pressed,

1. Ignitor cable pinched or wet

1.

Free ignitor cable if pinched

there is no spark at ODS/pilot

 

 

 

by any metal or tubing. Keep

 

 

 

 

ignitor cable dry

 

2.

Ignitor electrode not connected

2.

Reconnect ignitor cable

 

 

to ignitor cable

3.

Replace ignitor cable

 

3.

Broken ignitor cable

 

4.

Bad piezo ignitor

4.

Replace piezo ignitor

 

5.

Ignitor electrode broken

5.

Replace pilot assembly

 

6.

Ignitor electrode positioned

6.

Replace pilot assembly

 

 

wrong

 

 

 

 

 

 

When ignitor button is pressed,

1. Gas supply turned off or equip-

1.

Turn on gas supply or open

there is spark at ODS/pilot but

 

ment shutoff valve closed

 

equipment shutoff valve

no ignition

2. Control knob not in PILOT

2.

Turn control knob to PILOT

 

 

position

 

position

 

3.

Control knob not pressed in

3.

Press in control knob while in

 

 

while in PILOT position

 

PILOT position

 

4.

Air in gas lines when installed

4.

Continue holding down con-

 

 

 

 

trol knob. Repeat igniting op-

 

 

 

 

eration until air is removed

 

5.

Depleted gas supply (propane/

5.

Contact local propane/LP gas

 

 

LP only)

 

company

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning

 

 

 

 

and Maintenance, page 22) or

 

 

 

 

replace ODS/pilot assembly

 

7.

Gas regulator setting is not

7.

Replace gas regulator

 

 

correct

 

 

111044-01F

www.desatech.com

23

Image 23
Contents 14,000 to 26,000 Btu/Hr with Thermostat Shown with Optional Cabinet Mantel/Hearth Base AccessoryHDCFTP, HDCFTN, Cgcftp and Cgcftn Table of Contents Safety Information Provide adequate clearances around air openings Local CodesProduct Information Unpacking Product FeaturesAssembly Assembling Hood Providing Adequate VentilationDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation Air From Outdoors InstallationVentilation AIR Ventilation Air From Inside BuildingLocating Fireplace Installation ItemsCheck GAS Type Rough Opening for Installing Wall BUILT-IN Fireplace InstallationAttaching Fireplace to Wall Studs If you have not assembled firebox, follow instructions onOptional Mantel Installation Mantel Clearances for BUILT- in InstallationRemoving Upper Louver Assembly Installing Blower AccessoryRemoving Valve Cover Shield Installing Blower Assembly Models Cgcftp and CgcftnClose lower louver door For Built-In InstallationExtension Cord Connecting to GAS SupplyAttaching Wood Base to Solid Floor Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Propane/LP For Your SafetyRead Before Lighting Equipment Shutoff ValveShutting Off Fireplace Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceBurner Flame Pattern Manual Lighting ProcedureInspecting Burner Thermostat Control OperationAir Passageways Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole CabinetObserved Problem Possible Cause Remedy TroubleshootingPress in control knob fully Out when control knob is reDelayed ignition of burner Manifold pressure is too low ODS/pilot lights but flame goesAir passageways on fireplace Burner orifice Clean burner see CleaningGas regulator defective Nance, Replace gas regulator Air in gas line Minute Operate burner until air isGas leak. See Warning Technical Service SpecificationsReplacement Parts Service HintsModels CGCFTP, CGCFTN, Hdcftp and Hdcftn Illustrated Parts BreakdownPart Number KEY Hdcftp Hdcftn Cgcftp Cgcftn Description QTY Parts ListAccessories FBD Parts CentralsLimited Warranty VENT-FREE Compact Fireplace Warranty InformationKeep this Warranty

CGCFTP, CGCFTN 14, HDCFTN specifications

Desa HDCFTN, CGCFTP, and CGCFTN 14 represent a significant advancement in the landscape of modern digital architecture. These entities are characterized by their unique blend of features, technologies, and characteristics that cater to various applications and industries.

At the core of these systems is the high-density computing and flexible trading network (HDCFTN) structure, which allows for scalable operations and enhanced processing capabilities. This architecture is designed to efficiently handle large volumes of data transactions, making it ideal for sectors such as finance, telecommunications, and research institutions. By incorporating distributed computing, HDCFTN can optimize resource allocation and significantly reduce latency compared to traditional centralized systems.

CGCFTP, or the Cloud-based Grid Computing for Financial Transactions Platform, serves as a robust framework that integrates real-time data processing and analysis. Its cloud-native design ensures seamless connectivity and scalability, enabling organizations to operate in a flexible environment. The platform utilizes microservices architecture, which allows for independent deployment and scaling of different components, leading to improved performance and resilience.

Meanwhile, CGCFTN 14 focuses on providing end-to-end solutions for trading and financial operations. It incorporates advanced security protocols and compliance features, addressing the increasing regulatory demands prevalent in the financial sector. Utilizing blockchain technology, CGCFTN 14 ensures data integrity and transparency, creating trust among users while minimizing the risk of fraud or misconduct.

The combination of artificial intelligence (AI) and machine learning (ML) within these frameworks enhances predictive analytics and decision-making processes. With algorithms that learn from historical data, organizations can anticipate market trends and adjust their strategies accordingly. The integration of big data analytics further fuels real-time insights, empowering businesses to respond swiftly to market changes.

Moreover, these innovative systems embrace interoperability, connecting with various existing technologies and platforms. This flexibility allows organizations to leverage their current investments while still benefiting from new technological advancements. In summary, Desa HDCFTN, CGCFTP, and CGCFTN 14 exemplify the future of digital infrastructure, characterized by high density, cloud integration, advanced security, and intelligent analytics, driving efficiency and innovation across industries.