LOCATION OF TERMINATION CAP

LOCATION OF TERMINATION CAP

N

N

D

E V

B L

C

Fixed

 

V

Closed

 

 

 

Openable

 

F V

Openable

B

Fixed

Closed

H

V

B

I

G

B

B

V J X

G

A

M

V

K X

V

G V A

V TERMINATION CAP

X AIR SUPPLY INLET

G

GAS METER

RESTRICTED AREA (TERMINATION PROHIBITED)

A= clearance above grade, veranda, porch, deck, or balcony [*12 inches (30.5mc) minimum]

B= clearance to window or door that may be opened

[12 inches (30.5cm) minimum]

C = clearance to permanently closed window [minimum 12 inches (30.5cm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (61cm) from the center-line of the terminal [18 inches (45.7cm) minimum]

E= clearance to unventilated soffit [12 inches (30.5cm) minimum]

F= clearance to outside corner (see below)

G= clearance to inside corner (see below)

H= *not to be installed above a meter/regulator assembly within

36 inches (91.4cm) horizontally from the center-line of the regulator

I= clearance to service regulator vent outlet [*72 inches (182.9cm) minimum]

J= clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12 inches (30.5cm) minimum]

K= clearance to a mechanical air supply inlet [*72 inches (182.9cm) minimum]

L= clearance above paved side-walk or a paved driveway located on public property [*84 inches (213.3cm) minimum]

M= clearance under veranda, porch, deck [*12 inches (30.5cm) minimum ]

N= clearance above a roof shall extend a minimum of 24 inches (61cm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (45.7cm)

vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor*

*as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A. Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

Outside Corner

A

 

 

 

A = 6" (15.2cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B B = 6" (15.2cm)

Recessed Location

D

C

C

E

V

Balcony with No Side Wall

G

V

G = 12" (30.5cm) minimum clearance

Balcony with Perpendicular Side Wall

H

V

J

Combustible &

Noncombustible

H = 24" (61cm)

J = 20" (50.8cm)

C = Maximum depth of 48" (121.9cm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (965mm) Noncombustible - 24" (61cm)

E = Clearance from corner in recessed location- Combustible - 6" (15.2cm) Noncombustible - 2" (5.1cm)

Figure 7 - Minimum Clearances for Termination Cap

For..com

111253-01C

Image 6
Contents OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Table of Contents Safety InformationProduct Identification Local CodesProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Siding Standoff Combustible Exterior Horizontal Termination Configurations Ground Floor InstallationCorner Installation Venting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations High Altitude Installation Parts Lists for Venting Kits and ComponentsDesa 5/8 Pipe & Vent Kits Model BK Installation Fireplace InstallationInstalling Optional Blower Accessory Check GAS TypeModel BKT Installation Attaching Speed Control to FireboxInstalling GAS Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Connecting Fireplace to GAS Supply Gas ConnectionPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Removing Louver Panels Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Glass DoorInstalling LOGS, Lava Rock and Glowing Embers Installing Rear Brick PanelInstalling Log No Installing Log No Wiring Diagram Wall Switch InstallationOptional Remote Control Lighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To ApplianceInspecting Burners Operating Optional Blower AccessoryPilot Assembly Burner Flame PatternPilot and Burners Cleaning MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning statement at Illustrated Parts Breakdown ModelsParts List VV36EPSB1 VV36EPHB1 Description QTYBurner Assembly for Models KEY Part Number Description QTY Technical Service Replacement PartsService Hints SpecificationsOwners Registration Form Postage Required Accessories Warranty Information

V36EP-A SERIES, V36EN-A SERIES, VV36EPB(1) SERIES, VV36ENB(1) SERIES specifications

The Desa V36EP-A SERIES, V36EN-A SERIES, VV36EPB(1) SERIES, and VV36ENB(1) SERIES represent an innovative lineup of gas vent-free fireplaces designed to enhance the ambiance of any living space while providing efficient heating. These models are particularly noted for their cutting-edge technology and elegant designs, ensuring they blend seamlessly with various interior styles.

The V36EP-A and V36EN-A SERIES are equipped with a highly efficient burner system that provides an impressive heat output without the need for a chimney or venting, making them highly suitable for both new constructions and renovations. These models utilize advanced control systems that allow for easy adjustment of flame height and heat levels, thereby providing users with precise control over their environment.

The VV36EPB(1) SERIES and VV36ENB(1) SERIES take these features a step further with their improved efficiency ratings and attractive detailing. These models feature realistic flame patterns and log sets that mimic the look of traditional wood-burning fireplaces, creating a warm and inviting atmosphere. The ceramic fiber logs not only enhance visual appeal but also contribute to better heat distribution and retention.

One of the standout characteristics of these fireplace series is their incorporation of advanced safety features. Equipped with oxygen depletion sensors and a durable tempered glass front, they ensure safe operation without compromising on performance. The low emissions and reduced environmental impact align with modern energy efficiency standards.

Additionally, the Desa fireplaces come with options for remote controls and programmable thermostats, allowing for hassle-free operation and energy management. Customization options are also abundant, with various finishes and styles available to fit individual preferences and home decor.

In summary, the Desa V36EP-A SERIES, V36EN-A SERIES, VV36EPB(1) SERIES, and VV36ENB(1) SERIES deliver a combination of aesthetic appeal, modern technology, and practical heating solutions. Their vent-free designs make them versatile options for homeowners seeking efficient and stylish heating methods without the need for extensive installation. With their blend of safety, efficiency, and elegance, these fireplace series are poised to redefine comfort and style in home heating.