Desa VCGF30NR installation manual Unvented Natural GAS Fireplace, Safety Information

Page 2

®

UNVENTED NATURAL GAS FIREPLACE

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. Improper use of this fireplace can cause seri- ous injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural Gas: Natural gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not ap- proved for use with this fireplace.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Fireplace front becomes very hot when running fireplace. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shut- down. Allow surfaces to cool be- fore touching.

Carefully supervise young chil- dren when they are in the room with fireplace. When using the hand-held remote accessory, keep selector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this fireplace with the front window assembly and hood in place. Make sure front window assembly and hood are in place before running fireplace.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

3.This fireplace shall not be installed in a bedroom or bathroom.

4.Do not use this fireplace as a wood- burning fireplace. Use only the logs provided with the fireplace.

5.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

6.This fireplace is designed to be smoke- less. If logs ever appear to smoke, turn off fireplace and call a qualified ser- vice person. Note: During initial op- eration, slight smoking could occur due to log curing and fireplace burning manufacturing residues.

7.To prevent the creation of soot, follow the instructions in Cleaning and Main- tenance, page 21.

8.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

9.This fireplace needs fresh air ventila- tion to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combus- tion and Ventilation, pages 4 through 6. If fireplace keeps shutting off, see Troubleshooting, pages 17 through 19.

10.Do not run fireplace

• where flammable liquids or vapors are used or stored

• under dusty conditions

11.Do not use this fireplace to cook food or burn paper or other objects.

12.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

13.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

14.Turn fireplace off and let cool before servicing. Only a qualified service per- son should service and repair fireplace.

15.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

2

104636

Image 2
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Unvented Natural GAS FireplaceLocal Codes Remote Control AccessoriesProduct Identification UnpackingProduct Features AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Building Ventilation AIRVentilation Air From Inside Ventilation Air From OutdoorsCheck GAS Type InstallationInstalling Deflector and Hood Electrical HookupInstallation Clearances Conventional Fireplace InstallationBUILT-IN Fireplace Installation Location of Nailing FlangesInstalling GAS Piping to Fireplace Location InstallationsMantel Clearances for BUILT-IN Installation Installation Items NeededConnecting Fireplace to GAS Supply Attaching Flexible Gas Lines TogetherChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing Logs Will create sootLighting Instructions For Your Safety Read Before LightingOperating Fireplace Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Pilot Flame Pattern Inspecting BurnersOptional Blower Operation Burner Primary AIR HolesTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Wiring Diagram Replacement PartsSpecifications Technical ServiceLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Front Window GlassAccessories Receiver and HAND-HELD Remote Control KIT Ghrc Series Brass Trim Accessory GA6090Cleaning KIT CCK WALL-MOUNT Thermostat Switch GWMT1Illustrated Parts Breakdown Remote Ready Catalytic Model VCGF30NRParts List KEY Part Number Description QTYFireplace VCGF30NR Parts List Warranty Information