Continental CDVS500-P, CDVS500-N manual Table of Contents

Page 2

2

TABLE of CONTENTS

Pg 2-4

INTRODUCTION

Pg 14

GAS INSTALLATION

 

Warranty

15-16 FINISHING

 

General Instructions

 

 

Door Opening & Closing

 

General Information

 

 

 

Trivet Installation

 

Care of Glass & Plated Parts

 

 

 

Log Placement

5

LOCATION & CLEARANCES

 

17-18 OPERATION / MAINTENANCE

 

 

6-11

DIRECT VENT SPECIFICS

 

Spill Switch

MODEL CDVS500

 

Turbo Burner

 

Vent Lengths/Air Terminal Locations

 

Operating Instructions

 

Special Installation Example

 

Maintenance

 

Offset Installation Example

19

REPLACEMENT BLOWER

 

Wall & Ceiling Protection

 

20

ADJUSTMENTS

 

Horizontal Venting Installation

 

Vertical Venting Installation

 

Pilot Burner Adjustment

 

Stove Vent Connection

 

Venturi Adjustments

 

Mobile Home Installation

21-22 REPLACEMENTS

 

 

12-13 B-VENT SPECIFICS

 

Ordering Replacement Parts

MODEL CS500

 

Terminal Kits

 

Chimney Installation

 

Accessories

 

 

Replacement Parts

 

'B' Vent Installation

 

 

 

 

 

Adding Vent Sections

23-24 TROUBLE SHOOTING GUIDE

 

Flashing and Storm Collar Installation

 

 

'B' Vent Adaptations

Combustion Air

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE

WARNING

The stove is a vented gas-fired heater. Do not burn wood or other materials in this stove.

Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children and animals away when the stove is hot.

Due to high temperatures, the stove should be located out of traffic and away from furniture and draperies.

Clothing or other flammable material should not be placed on or near the stove.

Any safety screen or guard removed for servicing must be replaced prior to operating the stove.

It is imperative that the control compartments, burners and circulating blower and its passageway in the stove and venting system are kept clean. The stove and its venting system should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpet- ing, bedding material, etc. The stove area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.

Under no circumstances should this stove be modified.

This stove must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.

Do not use this stove if any part has been under water. Immediately call a qualified service technician to inspect the stove and to replace any part of the control system and any gas control which has been under water.

Do not operate the stove with the glass door opened, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Do not strike or slam shut the stove glass door.

This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.

W415-0514 / 05.30.05

Image 2
Contents GAS-FIRED Stoves Table of Contents Conditions and Limitations Care of GLASS, and Plated Parts General InstructionsGeneral Information Window Opening Location & ClearancesCDVS500 and CS500 Direct Vent Specifics Model CDVS500 AIR Terminal Installations Horizontal Offset Installation ExampleSpecial Installation Example Wall and Ceiling Protection Horizontal Venting Installation Vertical Venting InstallationContinue with Gas Installation Stove Vent Connection Mobile Home InstallationVent Specifics Model CS500 Chimney InstallationInstalling B Vent Adding Vent SectionsCombustion AIR Installing Flashing Storm CollarVent Adaptations TWO Screws Must be RE-SECURED. FigureDirect Vent Model CDVS500 GAS InstallationGAS Installation Vent Model CS500 only Vent Model CS500Finishing Fire Viewing Door Side Door Valve Control DoorLOG Placement Spill Switch Operation / MaintenanceTurbo Burner Operation Maintenance Operating InstructionsFor Your Safety Read Before Lighting Replacement Blower Installation Front Burner Rear Burner AdjustmentsPilot Burner Adjustment Venturi Adjustment Replacements Ing informationPage Trouble Shooting Guide Symptom Problem Test SolutionModel CDVS500 only Models CDVS500 only

CDVS500-N, CDVS500-P specifications

The Continental CDVS500-P and CDVS500-N are advanced vehicle sensor solutions specifically designed for enhancing driver safety and facilitating automation in modern vehicles. These systems represent cutting-edge technology in the realm of automotive sensors, focusing on improving situational awareness through comprehensive environmental perception.

One of the main features of the CDVS500 series is its high-resolution sensor capabilities. Both the CDVS500-P and CDVS500-N utilize sophisticated imaging technologies that enable them to capture a wide field of view with exceptional clarity. This is crucial for applications such as adaptive cruise control, lane-keeping assistance, and collision avoidance systems, where accurate detection of nearby vehicles, pedestrians, and obstacles is a priority.

In addition to high-resolution imaging, these sensors employ advanced algorithms for real-time data processing. The integration of machine learning and artificial intelligence enhances the ability of the CDVS500 systems to interpret dynamic environments. This means that they can effectively differentiate between various objects, predicting their movements and assessing potential risks with remarkable accuracy.

Another notable characteristic is the robust performance of the CDVS500-P and CDVS500-N in diverse weather conditions. They are engineered to function effectively in rain, fog, and glare, ensuring reliable operation regardless of environmental variables. This resilience is vital for maintaining safety standards in vehicular automation, making these sensors a trusted choice for various automotive applications.

The connectivity features of the CDVS500 series also set them apart. They support seamless integration with existing vehicle systems and can communicate with other sensors to create a comprehensive view of the vehicle's surroundings. This interoperability is essential for next-generation driver assistance systems, promoting an ecosystem where multiple inputs are synthesized into cohesive feedback for the driver or autonomous driving system.

Moreover, both models are designed with a focus on energy efficiency and a compact form factor. This design not only saves space within the vehicle but also plays a role in extending the overall lifespan of the sensor by reducing thermal strain.

In summary, the Continental CDVS500-P and CDVS500-N represent a significant leap in automotive sensor technology, characterized by high-resolution imaging, advanced processing algorithms, robust environmental performance, and excellent connectivity. These attributes position them as vital components in the ongoing evolution toward safer and more autonomous driving experiences.