CONTINENTAL gas fireplaces are manufactured under the strict Standard of the world recognized

ISO 9001 : 2000 Quality Assurance Certificate.

CONTINENTAL products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station. Once assembled the complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from WOLF STEEL Ltd..

CONTINENTAL GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY

The following materials and workmanship in your new CONTINENTAL gas fireplace are warranted against defects for as long as you own the fireplace. This covers: combustion cham- ber, heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled components and aluminium extrusion trims.

Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves, thermal switch, switches, wiring, remote controls, igniter, gasketing, and pilot assembly are covered and WOLF STEEL LTD. will provide replacement parts free of charge during the first year of the limited warranty.

Any labour related to warranty repair is not covered.

CONDITIONS AND LIMITATIONS

WOLF STEEL LTD. warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears on the warranty registration card filed with WOLF STEEL Ltd. -- provided that the purchase was made through an authorized CONTINENTAL dealer and is subject to the following conditions and limitations:

This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.

The gas fireplace must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes.

This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this warranty.

This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel parts, mechanical breakage of PHAZER™ logs and embers, nor any venting components used in the installation of the fireplace.

WOLF STEEL Ltd. warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the first 10 years WOLF STEEL Ltd. will replace or repair the defective parts at our option free of charge. From 10 years to life, WOLF STEEL LTD. will provide replacement burners at 50% of the current retail price.

In the first year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions.

After the first year, with respect to this President's Limited Lifetime Warranty, WOLF STEEL LTD. may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).

WOLF STEEL Ltd. will not be responsible for installation, labour, or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not covered by this warranty.

Notwithstanding any provisions contained in this President's Limited Lifetime Warranty, WOLF STEEL’S responsibility under this warranty is defined as above and it shall not in any event extend to any incidental, consequential or indirect damages.

This warranty defines the obligations and liability of WOLF STEEL Ltd. with respect to the CONTINENTAL gas fireplace and any other warranties expressed or implied with respect to this product, its components or accessories are excluded.

WOLF STEEL Ltd. neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. WOLF STEEL Ltd. will not be responsible for: over-firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting configurations, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.

Any damages to fireplace, combustion chamber, heat exchanger, brass trim or other component due to water, weather damage, long periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of WOLF STEEL Ltd.

The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration card must be returned within fourteen days to register the warranty.

WOLF STEEL Ltd. reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.

ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. CONTINENTAL® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD.

W415-0514 / 05.30.05

Image 3
Contents GAS-FIRED Stoves Table of Contents Conditions and Limitations General Instructions General InformationCare of GLASS, and Plated Parts Location & Clearances CDVS500 and CS500Window Opening Direct Vent Specifics Model CDVS500 AIR Terminal Installations Offset Installation Example Special Installation ExampleHorizontal Wall and Ceiling Protection Vertical Venting Installation Horizontal Venting InstallationStove Vent Connection Mobile Home Installation Continue with Gas InstallationAdding Vent Sections Chimney InstallationInstalling B Vent Vent Specifics Model CS500TWO Screws Must be RE-SECURED. Figure Installing Flashing Storm CollarVent Adaptations Combustion AIRVent Model CS500 GAS InstallationGAS Installation Vent Model CS500 only Direct Vent Model CDVS500Fire Viewing Door Side Door Valve Control Door FinishingLOG Placement Operating Instructions Operation / MaintenanceTurbo Burner Operation Maintenance Spill SwitchFor Your Safety Read Before Lighting Replacement Blower Installation Adjustments Pilot Burner Adjustment Venturi AdjustmentFront Burner Rear Burner Ing information ReplacementsPage Symptom Problem Test Solution Trouble Shooting GuideModels CDVS500 only Model CDVS500 only

CDVS500-N, CDVS500-P specifications

The Continental CDVS500-P and CDVS500-N are advanced vehicle sensor solutions specifically designed for enhancing driver safety and facilitating automation in modern vehicles. These systems represent cutting-edge technology in the realm of automotive sensors, focusing on improving situational awareness through comprehensive environmental perception.

One of the main features of the CDVS500 series is its high-resolution sensor capabilities. Both the CDVS500-P and CDVS500-N utilize sophisticated imaging technologies that enable them to capture a wide field of view with exceptional clarity. This is crucial for applications such as adaptive cruise control, lane-keeping assistance, and collision avoidance systems, where accurate detection of nearby vehicles, pedestrians, and obstacles is a priority.

In addition to high-resolution imaging, these sensors employ advanced algorithms for real-time data processing. The integration of machine learning and artificial intelligence enhances the ability of the CDVS500 systems to interpret dynamic environments. This means that they can effectively differentiate between various objects, predicting their movements and assessing potential risks with remarkable accuracy.

Another notable characteristic is the robust performance of the CDVS500-P and CDVS500-N in diverse weather conditions. They are engineered to function effectively in rain, fog, and glare, ensuring reliable operation regardless of environmental variables. This resilience is vital for maintaining safety standards in vehicular automation, making these sensors a trusted choice for various automotive applications.

The connectivity features of the CDVS500 series also set them apart. They support seamless integration with existing vehicle systems and can communicate with other sensors to create a comprehensive view of the vehicle's surroundings. This interoperability is essential for next-generation driver assistance systems, promoting an ecosystem where multiple inputs are synthesized into cohesive feedback for the driver or autonomous driving system.

Moreover, both models are designed with a focus on energy efficiency and a compact form factor. This design not only saves space within the vehicle but also plays a role in extending the overall lifespan of the sensor by reducing thermal strain.

In summary, the Continental CDVS500-P and CDVS500-N represent a significant leap in automotive sensor technology, characterized by high-resolution imaging, advanced processing algorithms, robust environmental performance, and excellent connectivity. These attributes position them as vital components in the ongoing evolution toward safer and more autonomous driving experiences.