Desa VMH10TP Mantel Clearances for Built-In Installation, Side Firebox Mantel Shelf

Page 13

INSTALLING

Continued

6.Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to Gas Supply, page 17.

7.If the optional blower has been installed connect blower to electrical source.

Options one and two: Route blower electrical cord through side or rear access door of fireplace. Plug electrical cord into electrical outlet.

Option three: Have a licensed electrician connect blower to electrical source at junction box inside fireplace.

8.Bend four nailing flanges on outer casing with pliers (see Figure 10).

9.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange.

Nails or Wood

Screws

Nailing

Flanges

Figure 10 - Attaching Fireplace to Wall Studs

10.Check all gas connections for leaks. See Checking Gas Connections, page 18.

11.If using optional brass trim kit, install the trim after final finishing and/or painting of wall. See instructions included with brass trim accessory for attach- ing brass trim.

Mantel Clearances for Built-In Installation

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

10"

8"

6"

2 1/2"

Side of

Firebox

Mantel Shelf

20"

 

241/2"

271/2"

 

Distances to

Underside of

Built-in Mantel

Underside of

Mantel Shelf

All minimum distances are in inches

30"

Top of Fireplace Opening

Figure 11 - Minimum Mantel Clearances for Built-In Installation

If your installation does not meet the above minimum clearances, you must:

raise the mantel to an acceptable height, OR

 

 

remove the mantel.

Continued

 

13

 

 

 

 

 

 

103669

Image 13
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Safety Pilot Local Codes Product Features UnpackingPiezo Ignition System Thermostatic Heat ControlInstalling Log AssemblyProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Fireplace LocationVentilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Shown with Optional Mantel Ventilation Air From OutdoorsInstallation Items InstallationCheck GAS Type Locating FireplaceCeiling BUILT-IN Fireplace Installation InstallingSide Firebox Mantel Shelf Mantel Clearances for Built-In InstallationAttaching Brass Trim to Fireplace Optional Mantel InstallationAttaching Wood Base to Solid Floor Assembling Brass Trim Brass trim shipped with mantelExternal Regulator with Vent Pointing Down Connecting to GAS SupplyInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing GAS Supply Piping System Connecting to GAS Supply Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Fireplace GAS ConnectionsOperating Fireplace Pilot Operating FireplacePilot Flame Pattern Inspecting BurnerShutting Off Fireplace Shutting Off Burner Only pilot stays litIncorrect Pilot Flame Pattern Burner Flame PatternODS/PILOT and Burner Cleaning and Maintenance Trouble ShootingCabinet TROUBLE- Shooting See CleaningObserved Possible Remedy Problem Cause Top Ing statement atService Hints Replacement Parts Technical ServiceParts Under Warranty Parts Not Under WarrantyUnfinished GM921U Finished GM920F AccessoriesUnfinished GM721U Finished GM720F VMH10TP Model VMH10TP Parts ListKeep this Warranty Warranty Information

VMH10TP specifications

Desa VMH10TP is an innovative and versatile heating solution that stands out in the HVAC market. Designed with efficiency and user-friendliness in mind, this model caters to various heating needs in both residential and commercial settings. Its cutting-edge technology ensures that spaces are warmed quickly while minimizing energy consumption.

One of the main features of the Desa VMH10TP is its powerful heating capacity. The unit is equipped with a robust heating element that provides a remarkable output, making it suitable for larger rooms or open areas. Users can enjoy a comfortable ambient temperature, even during the harshest winter months. This model also includes adjustable heat settings, allowing users to easily customize their heating preferences according to specific needs or time of the day.

Incorporating advanced digital control systems, the Desa VMH10TP offers convenient programming options. Users can set timers, adjust temperature settings, and manage the unit remotely through integrated smart technologies. This feature not only enhances comfort but also promotes energy efficiency, as users can heat spaces just before arriving home or turn off the heater when not needed. The intuitive display makes it easy to navigate through various settings, catering to both tech-savvy individuals and those who prefer traditional operation.

Safety is another key characteristic of the Desa VMH10TP. The unit is designed with multiple safety features, including overheat protection, tip-over switch, and a cool-touch exterior. These safety measures ensure that both users and their spaces remain secure while the heater is in operation. The sleek design and compact size also make it easy to position the heater in various locations without sacrificing space.

Furthermore, the Desa VMH10TP is built with durability in mind. High-quality materials and construction standards ensure that the unit can withstand regular use over the years. With proper maintenance, users can expect a long lifespan, making this investment worthwhile.

In summary, the Desa VMH10TP is a stylish and effective heating solution that combines powerful performance with modern technology. Its customizable settings, safety features, and robust design make it an ideal choice for those seeking a reliable way to maintain comfort during cold seasons.