Desa VMH10TP installation manual Assembling Brass Trim Brass trim shipped with mantel

Page 15

INSTALLING

Continued

Assembling Brass Trim (Brass trim shipped with mantel)

1.Remove packaging from three remaining pieces of brass trim.

2.Locate two adjusting plates with set screws, and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in Figure 14.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 14).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 14).

6.While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other corner.

8.Set Brass Assembly aside for later installation.

Top Brass Trim

Set Screws

Slot

Adjusting

 

Plate

 

Shim

Mitered Edge

Slot

Side Brass Trim

 

Figure 14 - Assembling Brass Trim

Attaching Wood Base to Solid Floor

For attaching base to solid floors (concrete or masonry)

Note: Floor anchors and mounting screws are in hardware package. The hardware package is provided with fireplace.

1.Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or masonry), drill at least 1" deep.

2.Fold floor anchor as shown in Figure 15.

Figure 15 - Folding Anchor

3.Insert floor anchor (wings first) into hole. Tap anchor flush to floor.

4.Insert mounting screws through base and into floor anchors.

5.Tighten screws until base is firmly fastened to floor.

15

103669

Image 15
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Thermostatic Heat Control Local Codes Product Features UnpackingSafety Pilot Piezo Ignition SystemInstalling Log AssemblyConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Fireplace LocationVentilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Shown with Optional Mantel Ventilation Air From OutdoorsLocating Fireplace InstallationInstallation Items Check GAS TypeCeiling BUILT-IN Fireplace Installation InstallingSide Firebox Mantel Shelf Mantel Clearances for Built-In InstallationAttaching Brass Trim to Fireplace Optional Mantel InstallationAttaching Wood Base to Solid Floor Assembling Brass Trim Brass trim shipped with mantelExternal Regulator with Vent Pointing Down Connecting to GAS SupplyInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing GAS Supply Piping System Connecting to GAS Supply Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Fireplace GAS ConnectionsOperating Fireplace Pilot Operating FireplaceShutting Off Burner Only pilot stays lit Inspecting BurnerPilot Flame Pattern Shutting Off FireplaceIncorrect Pilot Flame Pattern Burner Flame PatternCleaning and Maintenance Trouble Shooting ODS/PILOT and BurnerCabinet TROUBLE- Shooting See CleaningObserved Possible Remedy Problem Cause Top Ing statement atParts Not Under Warranty Technical ServiceService Hints Replacement Parts Parts Under WarrantyAccessories Unfinished GM921U Finished GM920FUnfinished GM721U Finished GM720F VMH10TP Model VMH10TP Parts ListKeep this Warranty Warranty Information

VMH10TP specifications

Desa VMH10TP is an innovative and versatile heating solution that stands out in the HVAC market. Designed with efficiency and user-friendliness in mind, this model caters to various heating needs in both residential and commercial settings. Its cutting-edge technology ensures that spaces are warmed quickly while minimizing energy consumption.

One of the main features of the Desa VMH10TP is its powerful heating capacity. The unit is equipped with a robust heating element that provides a remarkable output, making it suitable for larger rooms or open areas. Users can enjoy a comfortable ambient temperature, even during the harshest winter months. This model also includes adjustable heat settings, allowing users to easily customize their heating preferences according to specific needs or time of the day.

Incorporating advanced digital control systems, the Desa VMH10TP offers convenient programming options. Users can set timers, adjust temperature settings, and manage the unit remotely through integrated smart technologies. This feature not only enhances comfort but also promotes energy efficiency, as users can heat spaces just before arriving home or turn off the heater when not needed. The intuitive display makes it easy to navigate through various settings, catering to both tech-savvy individuals and those who prefer traditional operation.

Safety is another key characteristic of the Desa VMH10TP. The unit is designed with multiple safety features, including overheat protection, tip-over switch, and a cool-touch exterior. These safety measures ensure that both users and their spaces remain secure while the heater is in operation. The sleek design and compact size also make it easy to position the heater in various locations without sacrificing space.

Furthermore, the Desa VMH10TP is built with durability in mind. High-quality materials and construction standards ensure that the unit can withstand regular use over the years. With proper maintenance, users can expect a long lifespan, making this investment worthwhile.

In summary, the Desa VMH10TP is a stylish and effective heating solution that combines powerful performance with modern technology. Its customizable settings, safety features, and robust design make it an ideal choice for those seeking a reliable way to maintain comfort during cold seasons.