OPERATING FIREPLACE

Continued

INSPECTING BURNER

22

TO TURN OFF GAS TO APPLIANCE

Shutting Off Fireplace

1. Turn control knob clockwise Clockwise to the OFF position.

2. Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob clockwise Clockwise to the PILOT position.

THERMOSTAT CONTROL OPERATION

The thermostat used on this fireplace senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature.

The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb measures the temperature of air near the fireplace cabinet. This may not always agree with room temperature (depend- ing on housing construction, installation location, room size, open air tempera- tures, etc.). Frequent use of your fireplace will let you determine your own comfort levels.

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, pages 20 and 21.

2.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pattern. Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.

Thermocouple

Pilot Burner

 

Figure 24 - Correct Pilot Flame Pattern

103669

Image 22
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Piezo Ignition System Local Codes Product Features UnpackingSafety Pilot Thermostatic Heat ControlAssembly Installing LogUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from Outdoors Shown with Optional MantelCheck GAS Type InstallationInstallation Items Locating FireplaceCeiling Installing BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Side Firebox Mantel ShelfOptional Mantel Installation Attaching Brass Trim to FireplaceAssembling Brass Trim Brass trim shipped with mantel Attaching Wood Base to Solid FloorConnecting to GAS Supply External Regulator with Vent Pointing DownConnecting Fireplace to GAS Supply Installation Items NeededConnecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping SystemPressure Testing Fireplace GAS Connections Manual Shutoff ValveOperating Fireplace Operating Fireplace PilotShutting Off Fireplace Inspecting BurnerPilot Flame Pattern Shutting Off Burner Only pilot stays litBurner Flame Pattern Incorrect Pilot Flame PatternODS/PILOT and Burner Cleaning and Maintenance Trouble ShootingCabinet See Cleaning TROUBLE- ShootingObserved Possible Remedy Problem Cause Ing statement at TopParts Under Warranty Technical ServiceService Hints Replacement Parts Parts Not Under WarrantyUnfinished GM921U Finished GM920F AccessoriesUnfinished GM721U Finished GM720F VMH10TP Parts List Model VMH10TPWarranty Information Keep this Warranty

VMH10TP specifications

Desa VMH10TP is an innovative and versatile heating solution that stands out in the HVAC market. Designed with efficiency and user-friendliness in mind, this model caters to various heating needs in both residential and commercial settings. Its cutting-edge technology ensures that spaces are warmed quickly while minimizing energy consumption.

One of the main features of the Desa VMH10TP is its powerful heating capacity. The unit is equipped with a robust heating element that provides a remarkable output, making it suitable for larger rooms or open areas. Users can enjoy a comfortable ambient temperature, even during the harshest winter months. This model also includes adjustable heat settings, allowing users to easily customize their heating preferences according to specific needs or time of the day.

Incorporating advanced digital control systems, the Desa VMH10TP offers convenient programming options. Users can set timers, adjust temperature settings, and manage the unit remotely through integrated smart technologies. This feature not only enhances comfort but also promotes energy efficiency, as users can heat spaces just before arriving home or turn off the heater when not needed. The intuitive display makes it easy to navigate through various settings, catering to both tech-savvy individuals and those who prefer traditional operation.

Safety is another key characteristic of the Desa VMH10TP. The unit is designed with multiple safety features, including overheat protection, tip-over switch, and a cool-touch exterior. These safety measures ensure that both users and their spaces remain secure while the heater is in operation. The sleek design and compact size also make it easy to position the heater in various locations without sacrificing space.

Furthermore, the Desa VMH10TP is built with durability in mind. High-quality materials and construction standards ensure that the unit can withstand regular use over the years. With proper maintenance, users can expect a long lifespan, making this investment worthwhile.

In summary, the Desa VMH10TP is a stylish and effective heating solution that combines powerful performance with modern technology. Its customizable settings, safety features, and robust design make it an ideal choice for those seeking a reliable way to maintain comfort during cold seasons.