Desa VMH10TP installation manual Assembly, Installing Log

Page 5

ASSEMBLY

WARNING

WARNING ICON

G 001

Always have branch support and screen in place before operating fireplace. This prevents excessive temperatures on fireplace surfaces.

ASSEMBLING FIREPLACE

Tools Required: Phillips screwdriver, 5/16" hex wrench, and slotted screwdriver

Installing Log

1.Remove back log, branch, and hood from log box. Discard protective packaging.

2.Remove two shipping screws above screen (see Figure 2).

3.Lift screen up and pull out to remove.

4.An optional blower is available. See Accessories, page 29. Install optional blower now. Follow installation instructions provided with blower.

5.Gently place back log on burner support (see Figure 2). The log should fit flat against top of burner support. Place two #10 one-inch-long screws through burner support into the log and tighten. Place branches on branch support (see Figure 2).

6.Reattach screen by placing the notches in the screen frame over the shoulder screws and pushing down.

Back Log

 

Screen Shipping Screw

 

Shoulder Screw

 

 

 

 

Burner

 

Screw

Support

 

 

Screw Branch

Support

Screen

Branch

 

Figure 2 - Assembling Fireplace

WARNING

WARNING ICON

G 001

Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in property damage or personal injury

Assembling Hood

1.Locate four black phillips sheet metal screws from the hardware packet.

2.Place hood over top edge of firebox wrapper.

3.Attach screws (see Figure 3).

Figure 3 - Assembling Hood

5

 

103669

Image 5
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Safety Pilot Local Codes Product Features UnpackingPiezo Ignition System Thermostatic Heat ControlInstalling Log AssemblyProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Fireplace LocationVentilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Shown with Optional Mantel Ventilation Air From OutdoorsInstallation Items InstallationCheck GAS Type Locating FireplaceCeiling BUILT-IN Fireplace Installation InstallingSide Firebox Mantel Shelf Mantel Clearances for Built-In InstallationAttaching Brass Trim to Fireplace Optional Mantel InstallationAttaching Wood Base to Solid Floor Assembling Brass Trim Brass trim shipped with mantelExternal Regulator with Vent Pointing Down Connecting to GAS SupplyInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing GAS Supply Piping System Connecting to GAS Supply Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Fireplace GAS ConnectionsOperating Fireplace Pilot Operating FireplacePilot Flame Pattern Inspecting BurnerShutting Off Fireplace Shutting Off Burner Only pilot stays litIncorrect Pilot Flame Pattern Burner Flame PatternCabinet Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner TROUBLE- Shooting See CleaningObserved Possible Remedy Problem Cause Top Ing statement atService Hints Replacement Parts Technical ServiceParts Under Warranty Parts Not Under WarrantyUnfinished GM721U Finished GM720F AccessoriesUnfinished GM921U Finished GM920F VMH10TP Model VMH10TP Parts ListKeep this Warranty Warranty Information

VMH10TP specifications

Desa VMH10TP is an innovative and versatile heating solution that stands out in the HVAC market. Designed with efficiency and user-friendliness in mind, this model caters to various heating needs in both residential and commercial settings. Its cutting-edge technology ensures that spaces are warmed quickly while minimizing energy consumption.

One of the main features of the Desa VMH10TP is its powerful heating capacity. The unit is equipped with a robust heating element that provides a remarkable output, making it suitable for larger rooms or open areas. Users can enjoy a comfortable ambient temperature, even during the harshest winter months. This model also includes adjustable heat settings, allowing users to easily customize their heating preferences according to specific needs or time of the day.

Incorporating advanced digital control systems, the Desa VMH10TP offers convenient programming options. Users can set timers, adjust temperature settings, and manage the unit remotely through integrated smart technologies. This feature not only enhances comfort but also promotes energy efficiency, as users can heat spaces just before arriving home or turn off the heater when not needed. The intuitive display makes it easy to navigate through various settings, catering to both tech-savvy individuals and those who prefer traditional operation.

Safety is another key characteristic of the Desa VMH10TP. The unit is designed with multiple safety features, including overheat protection, tip-over switch, and a cool-touch exterior. These safety measures ensure that both users and their spaces remain secure while the heater is in operation. The sleek design and compact size also make it easy to position the heater in various locations without sacrificing space.

Furthermore, the Desa VMH10TP is built with durability in mind. High-quality materials and construction standards ensure that the unit can withstand regular use over the years. With proper maintenance, users can expect a long lifespan, making this investment worthwhile.

In summary, the Desa VMH10TP is a stylish and effective heating solution that combines powerful performance with modern technology. Its customizable settings, safety features, and robust design make it an ideal choice for those seeking a reliable way to maintain comfort during cold seasons.