Vermont Casting STR42 manual Ceiling Chimney Hole Possible Obstructions, Cutting the Hole, 7412961

Page 10
Ceiling Chimney Hole/

STR/CVR Series Woodburning Fireplaces

Actual Centerpoint

 

Chimney

X

Centerline

Side of

STR/CVR

Cutting the Hole Plumb Line

Plumb Bob

Imaginary

Centerpoint

MODEL

X =

STR 33:

19" (483mm)

STR36

/ CVR36: 20�/�" 521mm)

STR42

/ CVR42: 23�/�" (597mm)

FP707

Fig. 10 Locate centerline of chimney with plumb line.

Ceiling Chimney Hole/

Possible Obstructions

The size of the hole in ceiling will vary with the angle at which the chimney passes through ceiling.

Drive a nail up through ceiling at marked chimney cen- ter point. Go to floor above and see where hole will be cut. Check to see where existing ceiling joists and other possible obstructions are located...i.e. wiring, plumbing etc... If necessary, re-position chimney and/or fireplace to avoid obstructions.

Cutting the Hole

Cover fireplace collar opening and cut proper sized chimney hole in chimney. The SK8 pipe allows you to run pipe through a typical 16” on center joist without

cutting joists.

Framing the Ceiling Hole

Frame the ceiling chimney hole as shown in Figure

12.It is good practice to use framing lumber that is the same size as the ceiling joists; this is a requirement at attic level.

The following table gives firestop spacer model num- bers:

 

 

Angle of Chimney at Ceiling

 

 

 

 

Size of Chimney

Vertical

30°

8" Flue

SKFS2A

SKFS6A

"SK" Series

14¹⁄" x 14¹⁄"

14¹⁄" x 25¹⁄"

 

 

(368mm x 368mm)

(368mm x 648mm)

 

 

FS2A

FS6A

11" CF 2-Wall

17¹⁄" x 17¹⁄"

17⁷⁄" x 29⁵⁄"

 

 

(445mm x 445mm)

(454mm x 753mm)

 

 

 

 

Fig. 11 Ceiling chimney hole sizes necessary for installing firestop spacer.

The inside dimension of the frame must be the same as the hole size selected from Figure 12 in order to provide the required air space (1¹/" (38mm)with SK8, 2" (51mm) with Model 11CF) between the outside diameter of the chimney and the edges of the framed

ceiling hole.

Existing

A/B

A/B

Ceiling

Joists

 

 

Chimney Hole

New Framing the Ceiling HoleFraming

Members Manual backgroundManual backgroundManual backgroundManual background

A"SK8" Series framing = 14���" X 14���" (368 x 368mm) B 11CF framing = 17���" X 17���" (445 x 445mm)

FP551A

Fig. 12 Typical frame for ceiling chimney hole.

10

7412961

Image 10
Contents Homeowners Installation and Operating Manual STR33 STR36 STR42 CVR36 CVR42DO NOT DISCARD THIS MANUAL: Retain for future use STR/CVR SeriesPrecautions Safety InformationTable of Contents STR/CVR Series Woodburning FireplacesSTR/CVR Series Woodburning Fireplaces STR Series Woodburning FireplaceCVR Series Woodburning Fireplace 7412961STR Fireplace STR/CVR Series Woodburning FireplaceSTR/CVR Series Woodburning Fireplaces CVR Fireplace7412961 Chase InstallationSTR/CVR Series Woodburning Fireplaces Fig. 4 Fireplace and chase parts identificationIllustration Key Chimney Requirements - Offset Installations30˚ Elbow Offsets STR/CVR Series Woodburning FireplacesPlanning the Chimney Run Planning InformationMounting the Fireplace The Ten Foot RuleChimney Supports InstallationChase Installation Insulating Fireplace Enclosure for Cold ClimatesFraming Straight-UpChimney InstallationOffset Installation Chimney Set-upFraming the Ceiling Hole Ceiling Chimney Hole Possible ObstructionsCutting the Hole STR/CVR Series Woodburning FireplacesSTR/CVR Series Woodburning Fireplaces Positioning, Safety Strips Securing the FireplaceOutside Air Kit 7412961Proper Firestop Spacer Installation Installing the Chimney SystemInstalling the Firestop Spacer in the Ceiling HoleAdditional Ceilings Continue Installing Pipe to Complete RunCanadian Requirements for Insulation Shield Penetrating the RoofInstalling Chimney In a Chase Install Remainder of Chimney SectionsInstalling Top Housing or Termination Air Space ClearancesMantel Clearance STR/CVR Series Woodburning Fireplaces7412961 Mantel ClearanceB C C Side Wall ProtectionSTR/CVR Series Woodburning Fireplaces B D CMinimum Wall Clearances Minimum Hearth Extension DimensionsHearth Installation STR/CVR Series Woodburning FireplacesExample for Common Brick COMMON MATERIALS AND FACTORSSTR/CVR Series Woodburning Fireplaces 7412961STR/CVR Series Woodburning Fireplaces Installing Line for Gas Logs7412961 Description CVR36/42 SERIESSTR/CVR Series Woodburning Fireplaces CVR36STR/CVR Series Woodburning Fireplaces STR33/36/42 SERIES7412961 Accessories STR/CVR Series Woodburning FireplacesChimney Components STR/CVR Series Woodburning FireplacesSTR/CVR Series Woodburning Fireplaces U.S. Chimney Components, contdCanada FirestopSTR/CVR Series Woodburning Fireplaces 7412961STR/CVR Series Woodburning Fireplaces 7412961B.Firegrate, Glass Doors, Outside Air System LIMITED WARRANTY & 30 YEAR PROTECTION PLAN7412961 C. Fan MotorCFM Corporation