Vermont Casting STR36 Installing the Chimney System, Installing the Firestop Spacer, 7412961

Page 12
Installing the Chimney System

STR/CVR Series Woodburning Fireplaces

Installing the Chimney System

Start by attaching the first chimney section to the collar on top of the fireplace.

Install the pipe as pictured in Figure 16. When you get a good lock, you will hear the pipe clearly snap together. Once sections are snap-locked in place, it is extremely difficult to get them apart. Make sure the pipe is firmly snapped and locked together as each pipe section is mounted.

When installing elbows, only outer pipe will snap- lock. Middle pipes simply slide into position. Be sure to always attach straps on upper elbow to a structural framing member. (Fig. 17)

Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer. Refer to Figure 18 for appropri- ate spacer orientation.

Installing the Firestop Spacer

in the Ceiling Hole

A firestop spacer is used to keep pipe spaced properly and required for safety.

Nail the firestop spacer (at each corner) to the framing members of the ceiling hole. NOTE: A firestop spacer is not required at the roof.

Hole sizes listed in Figure 12 for angled firestop spac- ers provide minimum required air space to chimney pipe for ceiling thickness up to 8" (203mm). When combined thickness of ceiling material, ceiling joists and flooring material exceeds 8" (203mm), adjustments must be made in framing to assure that minimum air spaces to chimney are maintained.

Proper Firestop Spacer Installation

Figure 18 shows different installation procedures for both an area that is an attic and an area that is not an attic.

Pipe Section

Pipe Rim

Installing the Firestop Spacer Hem

in the Ceiling Hole Lance

Pipe

Rim

FP711

Fig. 16 Install pipe, listening for the snap-lock to fasten.

Elbow Strap

Support Structure

 

Elbow Strap (must be tight)

Ceiling Hole Fram- ing

Angled Strap

Angle Firestop

 

Chimney Support

 

Strap

FP270/271

(must be tight)

 

Fig. 17 Attach straps to a structural framing member.

If the area above the ceil- ing is not an attic, posi- tion the firestop spacer with the flange on the ceil- ing side and the angled portion extending up into the hole.

If the area above the ceiling is an attic, position the firestop spacer with the flange on the top of the framed hole and the angled portion extending down into the hole.

12

 

Attic Installation

Ceiling Installation

 

 

Nails (4)

 

 

Joist

 

 

Firestop

 

 

Spacer

 

 

Firestop

 

 

Spacer

 

 

Joist

 

 

Nails (4)

FP593

 

 

Fig. 18

Installing firestop spacer.

 

 

 

7412961

Image 12
Contents STR33 STR36 STR42 CVR36 CVR42 DO NOT DISCARD THIS MANUAL: Retain for future useHomeowners Installation and Operating Manual STR/CVR SeriesSafety Information Table of ContentsPrecautions STR/CVR Series Woodburning FireplacesSTR Series Woodburning Fireplace CVR Series Woodburning FireplaceSTR/CVR Series Woodburning Fireplaces 7412961STR/CVR Series Woodburning Fireplace STR/CVR Series Woodburning FireplacesSTR Fireplace CVR FireplaceChase Installation STR/CVR Series Woodburning Fireplaces7412961 Fig. 4 Fireplace and chase parts identificationChimney Requirements - Offset Installations 30˚ Elbow OffsetsIllustration Key STR/CVR Series Woodburning FireplacesPlanning Information Mounting the FireplacePlanning the Chimney Run The Ten Foot RuleInstallation Chase InstallationChimney Supports Insulating Fireplace Enclosure for Cold ClimatesStraight-UpChimney Installation Offset InstallationFraming Chimney Set-upCeiling Chimney Hole Possible Obstructions Cutting the HoleFraming the Ceiling Hole STR/CVR Series Woodburning FireplacesPositioning, Safety Strips Securing the Fireplace Outside Air KitSTR/CVR Series Woodburning Fireplaces 7412961Installing the Chimney System Installing the Firestop SpacerProper Firestop Spacer Installation in the Ceiling HoleContinue Installing Pipe to Complete Run Canadian Requirements for Insulation ShieldAdditional Ceilings Penetrating the RoofInstall Remainder of Chimney Sections Installing Top Housing or TerminationInstalling Chimney In a Chase Air Space ClearancesSTR/CVR Series Woodburning Fireplaces 7412961Mantel Clearance Mantel ClearanceSide Wall Protection STR/CVR Series Woodburning FireplacesB C C B D CMinimum Hearth Extension Dimensions Hearth InstallationMinimum Wall Clearances STR/CVR Series Woodburning FireplacesCOMMON MATERIALS AND FACTORS STR/CVR Series Woodburning FireplacesExample for Common Brick 7412961Installing Line for Gas Logs STR/CVR Series Woodburning Fireplaces7412961 CVR36/42 SERIES STR/CVR Series Woodburning FireplacesDescription CVR36STR33/36/42 SERIES STR/CVR Series Woodburning Fireplaces7412961 Accessories STR/CVR Series Woodburning FireplacesChimney Components STR/CVR Series Woodburning FireplacesU.S. Chimney Components, contd CanadaSTR/CVR Series Woodburning Fireplaces FirestopSTR/CVR Series Woodburning Fireplaces 7412961STR/CVR Series Woodburning Fireplaces 7412961LIMITED WARRANTY & 30 YEAR PROTECTION PLAN 7412961B.Firegrate, Glass Doors, Outside Air System C. Fan MotorCFM Corporation