Vermont Casting RFS32 Cleaning Procedure, Flame Adjustment RN/RP Models, Flame Characteristics

Page 11

CLEANING PROCEDURE

1.Turn off pilot light at gas valve.

2.Remove front glass.

3.Remove logs.

CAUTION: LOGS MAY BE HOT

4.Vacuum burner compartment especially around orifice/ primary air openings.

5.Reinstall logs.

6.Check pilot and main burner operation.

7.Reinstall front glass.

8.Recheck pilot and main burner operation.

9.Check visually the flame pattern and compare with Fig. 21 or 22.

FLAME ADJUSTMENT (RN/RP MODELS)

For units equipped with Hi/Lo valves, flame adjustment is accomplished by rotating the Hi/Lo adjustment knob located near the centre of the gas control. (Fig. 18a & b)

 

IH

Turn

Turn clockwise

counterclockwise

to lower

to increase

flame height.

flame height.

 

 

LO

 

 

 

 

Fig. 18a

 

 

 

 

 

 

 

 

Turn

 

 

Turn clockwise

counterclockwise

 

 

 

 

to increase

to decrease

 

 

I

L

flame height.

flame height.

 

H

O

 

Fig. 18b

TEMPERATURE ADJUSTMENT

(TN/TP MODELS)

The Hi/Lo reference on the control knob (Fig. 19) is to indicate a higher or lower temperature setting. This setting

controls the heat by reducing then

 

 

shutting off the flame as the desired

 

 

temperature is reached. Position

 

 

the control knob where it effectively

LO

HI

maintains a comfortable room

 

OFF

 

PILOT

temperature.

 

 

 

 

 

Fig. 19

FLAME CHARACTERISTICS

It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to the pictorials illustrated below (Fig. 20, 21). If any of the flames appear abnormal call a service person.

- 11 -

3/8" - 1/2"

SIT VALVE

Fig. 20

PSE VALVE

RFS22

RFS32

Fig. 21

RFS42

CERAMIC REFRACTORY

RFS42 ONLY

1.Remove bay window assembly and glass frame (see "Glass frame Removal" section).

2.Remove logs from the unit.

LOGS MAY BE HOT

3. Remove refractory from packaging.

Refractory are fragile and must be handled with care. Where at all possible, two hands should be used when handling.

4.Take centre refractory piece and place it at the very back of the firebox.

5.Take left or right side refractory and slide it along the side of the firebox and on top of the bottom support channel. Be sure to slide it back to hold the centre piece in place and the leading edge faces forward.

6.Fasten top tab support against the refractory to hold it in place.

7.Repeat steps 5 and 6 for remaining side refactory.

8.Insert refractory pieces into the Bay Window as per Fig. 23.

 

 

 

Left

 

 

 

 

 

 

 

 

 

 

 

Right

 

 

 

Side

 

 

 

Centre

 

 

 

Side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Leading

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Leading

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Edge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Edge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 22

Fig. 23

Image 11
Contents What to do if YOU Smell GAS RFS22 RFS32 RFS42Table of Contents Clearances to Combustibles Installation InstructionsPlease Review the Following Carefully Locating Your Majestic GAS FireplaceModel RFS42 Fireplace DimensionsModel RFS22 Model RFS32GAS Inlet & Manifold Pressures GAS SpecificationsGAS Line Installation Certified toOptional FAN KIT FK24 Installation of Remote Switch for RN/RP GAS ValveVenting of the RFS22/RFS32/RFS42 Fireplace Common Flue InstallationsVenting Instructions Combustion AIR Vent Safety SystemTrim Removal Operating InstructionsGeneral Glass Information Louvre RemovalMaintenance Glass CleaningInstallation of Logs Burner Lava Rock Flame Characteristics Cleaning ProcedureFlame Adjustment RN/RP Models Temperature Adjustment TN/TP ModelsTo Turn OFF GAS to Fireplace For Your Safety Read Before LightingLighting Instructions SIT 630 GAS Valve Symptom Possible Causes Corrective Action Trouble Shooting the GAS Control SystemTrouble Shooting the GAS Control System Start Honeywell Millivolt ValveRFS22 RFS32 RFS42 Replacement Parts ListReplacement Parts Options Remote Control