CLEANING PROCEDURE
1.Turn off pilot light at gas valve.
2.Remove front glass.
3.Remove logs.
CAUTION: LOGS MAY BE HOT
4.Vacuum burner compartment especially around orifice/ primary air openings.
5.Reinstall logs.
6.Check pilot and main burner operation.
7.Reinstall front glass.
8.Recheck pilot and main burner operation.
9.Check visually the flame pattern and compare with Fig. 21 or 22.
FLAME ADJUSTMENT (RN/RP MODELS)
For units equipped with Hi/Lo valves, flame adjustment is accomplished by rotating the Hi/Lo adjustment knob located near the centre of the gas control. (Fig. 18a & b)
| IH | |
Turn | Turn clockwise | |
counterclockwise | ||
to lower | ||
to increase | ||
flame height. | ||
flame height. | ||
|
| LO |
| ||
|
|
| Fig. 18a | |
|
|
|
| |
|
|
|
| |
Turn |
|
| Turn clockwise | |
counterclockwise |
|
| ||
|
| to increase | ||
to decrease |
|
| ||
I | L | flame height. | ||
flame height. | ||||
| H | O |
|
Fig. 18b
TEMPERATURE ADJUSTMENT
(TN/TP MODELS)
The Hi/Lo reference on the control knob (Fig. 19) is to indicate a higher or lower temperature setting. This setting
controls the heat by reducing then |
|
|
shutting off the flame as the desired |
|
|
temperature is reached. Position |
|
|
the control knob where it effectively | LO | HI |
maintains a comfortable room |
| OFF |
| PILOT | |
temperature. |
| |
|
| |
|
| Fig. 19 |
FLAME CHARACTERISTICS
It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to the pictorials illustrated below (Fig. 20, 21). If any of the flames appear abnormal call a service person.
- 11 -
3/8" - 1/2"
SIT VALVE | Fig. 20 | PSE VALVE |
RFS22
RFS32
Fig. 21
RFS42
CERAMIC REFRACTORY
RFS42 ONLY
1.Remove bay window assembly and glass frame (see "Glass frame Removal" section).
2.Remove logs from the unit.
LOGS MAY BE HOT
3. Remove refractory from packaging.
Refractory are fragile and must be handled with care. Where at all possible, two hands should be used when handling.
4.Take centre refractory piece and place it at the very back of the firebox.
5.Take left or right side refractory and slide it along the side of the firebox and on top of the bottom support channel. Be sure to slide it back to hold the centre piece in place and the leading edge faces forward.
6.Fasten top tab support against the refractory to hold it in place.
7.Repeat steps 5 and 6 for remaining side refactory.
8.Insert refractory pieces into the Bay Window as per Fig. 23.
|
|
| Left |
|
|
|
|
|
|
|
|
|
|
| Right | |||||||||
|
|
| Side |
|
|
| Centre |
|
|
| Side | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Leading |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Leading | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
Edge |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Edge |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fig. 22
Fig. 23 |