OPERATING INSTRUCTIONS

GENERAL GLASS INFORMATION

Only glass approved for use in The CFM Majestic Products Company products may be used for replacement.

1.The use of substitute glass will void all product warranties.

2.Care must be taken to avoid breakage of the glass.

Under no circumstances should this fireplace be operated without the front glass or with a broken glass. Replacement of the glass (with gasket) as supplied by the manufacturer should be done by a licenced qualified service person.

For the RFS42 both front bay window glass and rear window glass need to be installed for proper performance. Under no circumstance should this fireplace be operated without the rear window glass or with broken glass. Replacement of the rear glass (with gasket) as supplied by the manufacturer should be done by a licensed qualified person.

LOUVRE REMOVAL

RFS22

Remove the front louvre assembly by lifting up and outward on the assembly.

RFS32

To remove louvres first remove the two (2) screws (Fig. 13) fastening the louvre assembly to the fireplace. Lift the louvre assembly straight out sliding the back guides out of the fireplace body. (To reinstall, reverse).

RFS42

The top louvre is assembled with the Bay Window Frame and is not required to be removed.

Front View

Screws

Fig. 13

 

TRIM REMOVAL

RFS22

1.Remove frame window brass trim by lifting up and out.

2.Remove decorative cover, which was at the bottom of the frame window trim by loosening two (2) nuts on the underside of the cover.

RFS32

1.Remove the two (2) outer 3/8" nuts holding the frame window brass trim in place. (Fig. 14)

2.Remove the frame window brass trim by moving it straight forward.

RFS42

Remove trim Bay Window, top and bottom by pulling

them from the unit. They are held with magnets.

- 9 -

GLASS REMOVAL

RFS22

1.Remove frame window brass trim (See Trim Removal section)

2.Remove remaining bottom 3/8" nut at the bottom of the frame window.

3.Remove frame window by pulling it forward and up.

RFS32

1 . Remove frame window brass trim (See Trim Removal section)

2.Remove remaining bottom 3/8" nut fat the bottom of the frame window.

3.Remove 3/8" nut from each side of the frame window (Fig. 14).

4.Remove frame window by pulling it forward and up.

GLASS

FRAME

OUTER NUTS

DRAWING 2

DRAWING 1

Side Nuts

BOTTOM NUT

Fig. 14

 

RFS42

1 . Remove both Bay Window brass trims (See Trim Removal section).

2.Open two clamps underneath the Bay Window that holds the Bay Window Frame and Glass Frame. (Fig. 15)

3.Lift and unhook the Bay Window assembly at the top.

4.Lift and unhook the Glass Frame at the top.

 

WINDOW

 

 

FRAME

 

 

PULL

 

PUSH

CLAMP HOOK

Fig. 15

CLAMP HANDLE

 

Image 9
Contents What to do if YOU Smell GAS RFS22 RFS32 RFS42Table of Contents Please Review the Following Carefully Installation InstructionsLocating Your Majestic GAS Fireplace Clearances to CombustiblesModel RFS22 Fireplace DimensionsModel RFS32 Model RFS42GAS Line Installation GAS SpecificationsCertified to GAS Inlet & Manifold PressuresOptional FAN KIT FK24 Installation of Remote Switch for RN/RP GAS ValveCommon Flue Installations Venting InstructionsVenting of the RFS22/RFS32/RFS42 Fireplace Combustion AIR Vent Safety SystemGeneral Glass Information Operating InstructionsLouvre Removal Trim RemovalGlass Cleaning Installation of Logs Burner Lava RockMaintenance Flame Adjustment RN/RP Models Cleaning ProcedureTemperature Adjustment TN/TP Models Flame CharacteristicsFor Your Safety Read Before Lighting Lighting InstructionsTo Turn OFF GAS to Fireplace SIT 630 GAS Valve Symptom Possible Causes Corrective Action Trouble Shooting the GAS Control SystemTrouble Shooting the GAS Control System Start Honeywell Millivolt ValveRFS22 RFS32 RFS42 Replacement Parts ListReplacement Parts Options Remote Control