Vermont Casting NV580 Replacement of Ceramic Hearth Panels, Remove air shutter from burner pan

Page 19

4.Remove both air shutters from burner pan by remov- ing shutter retaining screw then air shutter. (Fig. 26)

5.Install air shutters supplied in kit on burner pan. Replace shutter retaining screw. For conversion to Natural Gas adjust new air shutters so slots are cov- ered. For conversion to Propane Gas, adjust new air shutters so slots are open. NOTE: NV360 air shutter has only one hole, closed. Secure shutter retaining screws. (Fig. 27)

6.Re-install manifold to burner pan.

Burner Pan

 

Shutter

 

Retaining

 

Screw

 

Air Shutter

CO103

 

Fig. 26 Remove air shutter from burner pan.

 

Shutter Retaining

 

Burner

Screw

 

 

Natural Gas

 

 

Pan

 

 

 

Slots Covered

Front View

 

 

 

 

Shutter

 

Top View

 

 

 

Burner

Retaining

 

 

 

 

Pan

Screw

One (1) Hole Closed

NV360

 

 

 

 

 

Holes Open

 

Slots Open

 

 

 

Front View

 

Holes Open

Burner

 

Pan

 

 

 

NV580

 

 

Holes Open

CO110

 

 

 

Fig. 27 Install conversion air shutters.

 

NOTE: It is not necessary to remove the pilot tube for conversion.

7.Remove pilot hood by lifting up. (Fig. 28)

8.Remove pilot orifice with Allen wrench. (Fig. 29)

9.Install LP pilot orifice.

10.Re-install pilot hood and be sure to align with index tab. Installation complete.

NV360/580 Series

Pilot

Hood

Pilot

 

Bracket

 

 

CO105a

Fig. 28

Remove pilot hood.

Index Tab

Allen Wrench

Snap Ring

 

 

CO106a

Fig. 29 Remove pilot orifice.

 

Replacement of Ceramic Hearth Panels

1.Turn unit OFF. NOTE: Be sure unit is cool.

2.Remove glass.

3.Remove logs. Remove old hearth panels and dis- card.

4.Remove two (2) screws securing grate to hearth pan. (Fig. 30)

5.Set left and right panels on hearth and bring towards front of unit.

6.Replace assembly.

7.Replace logs.

8.Re-install glass panels.

 

Screw

Burner

Screw

 

 

 

Hearth Panels

 

Grate

 

 

 

 

Front of Unit

H100a

Fig. 30

Hearth panel location.

 

20003565

19

Image 19
Contents What to do if you smell gas Model NV360 NV580Table of Contents Please Read the Following Carefully Installation & Operating InstructionsNV360 NV580 Framing DimensionsAppliances Clearance to CombustiblesMantels Hearth ExtensionFinishing Air Shutter SettingGas Line Installation Framing and FinishingAlternate Switch Location Remote ON/OFF Switch InstallationEB-1 Electrical Box Ceiling Installation Install the Venting System Flashing and TerminationVenting Runs Operating Instructions Lava Rock Ember Material PlacementFlame Adjustment Flame CharacteristicsDV360 Inspecting the Venting SystemTest Chimney Draw DV580First Firing Vent Safety SwitchElectrical Connection Vent Safety Switch wiring, EN/EP units To Turn Off Gas to Heater Lighting And Operating InstructionsHoneywell VS8420 Standing Pilot TroubleshootingThermocouple Burner and Pilot Orifice Conversion Fuel Conversion InstructionsHoneywell Valve Nova SIT820 ValveRemove air shutter from burner pan Replacement of Ceramic Hearth PanelsBurner and Burner Compartment MaintenanceCleaning the Standing Pilot Control System Logs May Be HOTDescription NV360 NV580 NV360/580NV360/580 Fuel Conversion Kits Hard Direct Wire Hook Up AccessoriesFK12 Fan Assembly FK24 Fan AssemblyVent Adapter Remote ControlsCeramic Refractory Lining Decorative Frame TrimsNV360/580 Series Limited Lifetime Warranty CFM Corporation