Vermont Casting NV360 Install the Venting System Flashing and Termination, Ceiling Installation

Page 8

NV360/580 Series

INSIDE

Electrical Box

 

FRONT

 

OFUNIT

 

OUTSIDE

 

OF

UNIT

 

FRONT

FP580

Fig. 7 EB-1 receptacle.

6.Connect the white wire of the power line to the chrome screw of the socket assembly.

7.Connect the ground wire of the supply line to the green screw of the socket assembly.

8.Refit the socket assembly back into the electrical box and replace the cover plate. Secure the cable with the clamp on the outside of the unit to prevent strain on the connections.

9.The EB-1 electrical junction box is now ready to sup-

ply power to the FK12 or FK24 fan kits if fitted.

Install the Venting System,

Flashing and Termination

NOTE: The NV360 uses a 6" B-vent system. The NV580 uses an 8" B-vent system (refer to Accessories, Page 23 for adapter).

Refer venting installation instructions provided by the B-Vent manufacturer.

Refer to Page 4, Figure 1 to locate chimney centerline dimension from a combustible back wall.

Minimum vertical chimney height — 12 feet (3.65 m). (measured from the bottom of the fireplace)

Maximum vertical height — 40 feet (12 m).

Minimum height with two (2) elbows — 18 feet (5 m)

Elbow requirements allow a maximum of two (2) 90° elbows or four (4) 45° elbows per installation. (Two (2) 45° elbows = One (1) 90° elbow.) Refer to the venting chart for proper elbow offset runs.

For firestop positioning, refer to Figure 8. Only one (1) firestop required per frame. NOTE: A firestop is not required at the roof.

Attic Installation

Firestop position when area above ceiling is an attic. Nail (4)

Firestop Spacer

Joist

Ceiling Installation

Firestop position when area above ceiling is NOT an attic.

(Firestop/draftstop ap- pearances my vary. Only 1 firestop required per frame.)

FP384

Fig. 8 Firestop/draftstop positions.

8

20003565

Image 8
Contents Model NV360 NV580 What to do if you smell gasTable of Contents Installation & Operating Instructions Please Read the Following CarefullyFraming Dimensions NV360 NV580Clearance to Combustibles MantelsHearth Extension AppliancesAir Shutter Setting Gas Line InstallationFraming and Finishing FinishingEB-1 Electrical Box Remote ON/OFF Switch InstallationAlternate Switch Location Install the Venting System Flashing and Termination Ceiling InstallationVenting Runs Operating Instructions Ember Material Placement Flame AdjustmentFlame Characteristics Lava RockInspecting the Venting System Test Chimney DrawDV580 DV360Electrical Connection Vent Safety SwitchFirst Firing Vent Safety Switch wiring, EN/EP units Lighting And Operating Instructions To Turn Off Gas to HeaterTroubleshooting Honeywell VS8420 Standing PilotThermocouple Fuel Conversion Instructions Honeywell ValveNova SIT820 Valve Burner and Pilot Orifice ConversionReplacement of Ceramic Hearth Panels Remove air shutter from burner panMaintenance Cleaning the Standing Pilot Control SystemLogs May Be HOT Burner and Burner CompartmentNV360/580 Description NV360 NV580NV360/580 Fuel Conversion Kits Accessories FK12 Fan AssemblyFK24 Fan Assembly Hard Direct Wire Hook UpRemote Controls Ceramic Refractory LiningDecorative Frame Trims Vent AdapterNV360/580 Series Limited Lifetime Warranty CFM Corporation