Vermont Casting IRFSDV24, IRFSDV34 installation instructions To Install Vertical Venting

Page 15

installations. From 0 to a maximum of 8’ of vent pipe can be used between elbows (Fig. 25).

7DVCS must be used to support offsets (Fig.

26). This application will require that you first determine the roof pitch and use the appropriate starter kit. (See Venting Components List)

Irving Oil

TO INSTALL VERTICAL VENTING

1.

Locate your fireplace.

2.

Plumb to center of the (4”) flue collar from ceiling

 

above and mark position.

3.

Cut opening equal to 9-3/8” x 9-3/8” (240 mm x

 

240 mm).

4.

Proceed to plumb for additional openings through

MAX.

8 FEET

2.44m

45¡

40'(12m)

MAX.

8 FEET

2.44m

45¡

TYPICAL 7DVCS

APPLICATION

TYPICAL ROOF

SUPPORT

APPLICATION

 

the roof. In all cases, the opening must provide a

 

minimum of 1 inch clearance to the vent pipe, i.e.,

 

the hole must be at least 9-3/8” x 9-3/8” (240 mm x

 

240 mm).

5.

Place fireplace into position.

6.

Place firestop(s) #7DVFS or Attic Insulation Shield

 

#7DVAIS into position and secure (Fig. 29).

7.

Install roof support (Fig. 27) and roof flashing,

 

making sure upper flange of flashing is below the

 

shingles (Fig. 30).

8.

Install appropriate pipe sections until above the

 

flashing (Fig. 30).

9.

Install storm collar and seal around the pipe.

10.

Add additional vent lengths for proper height (Fig. 28).

11.

Apply high temperature sealant to 4” and 7” collars

 

of vertical vent termination and install.

Attic

 

Insulation

 

Shield

11"

 

JOIST

TYPICAL OFFSET INSTALLATION

Fig. 27

VENT TERMINATION

ROOF

2' Min.

ATTIC INSULATION

 

JOISTS

40 FEET

ATTIC INSULATION

(12.2m)

SHIELD

 

STORM COLLAR

ROOF FLASHING

ROOF SUPPORT

CEILING JIOSTS

Ceiling

11"

UPPER FLOOR

Installation

 

 

 

 

 

JOIST

FIRESTOP

SPACER

NAILS (4)

Fig. 29

Fig. 29 If there is a room above ceiling level, firestop spacer must be installed on both the bottom and the top side of the ceiling joists. If an attic is above ceiling level a 7DVAIS (Attic Insulation Shield) must be installed.

The enlarged ends of the vent section always face downward (Fig. 30).

Fig. 28

TYPICAL STRAIGHT-UP INSTALLATION

The minimum height of the vent above the highest point of penetration through the roof is 2 feet (Fig. 28).

SHEETMETAL

 

SCREWS (#5) Ñ

SHEETMETAL

3 PER JOINT

SCREWS (#5) Ñ

SEALANT

3 PER JOINT

STORM

SEALANT

 

COLLAR

STORM

COLLAR

Fig. 30

10004000

15

Image 15
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Installation & Operating Instructions Locating Your FireplaceClearance to Combustibles Fireplace Dimensions GAS Inlet and Manifold Pressures GAS SpecificationsGAS Line Installation When purging the gas line, the front glass must be removedON/OFF Switch or Millivolt Thermostat Installation of Remote Switch for RN/RP GAS ValveGeneral Venting INFORMATION-TERMINATION Location Canadian Installations US InstallationsTermination Clearances USA Installations Canadian InstallationsVertical Sidewall Installations , Dimension a plus B must not be greater than 17’ 5.2mVertical Sidewall Applications Example B To USE the Vent GraphSidewall Venting Graph Example aVent Opening Noncombustible Wall Vent Pipe AssemblyStep Vent Opening Combustible WallAlways install horizontal venting on a level plane Below Grade InstallationsMinimum Vertical THROUGH-THE-ROOF ApplicationsProceed to plumb for additional openings through To Install Vertical VentingCrimped END Venting Components Twist Lock Venting Components Window Frame Removal Installation of Logs & Burner Lava Rock MaterialGlass Cleaning Operating Instructions General Glass InformationFlame & Temperature Adjustment RFN/RFP Installation of Logs & BurnerMaintenance Cleaning ProcedureIRFSDV24 IRFSDV34 Flame & Temperature AdjustmentFlame Characteristics RN/RP ModelsOptional Frame Window Trim Kits Remote ControlsInstallation Procedure Optional Gold Trim KITTo Turn OFF GAS Fireplace For Your Safety Read Before LightingLighting and Operating Instructions Lighting InstructionsOperation Operating Instructions for RFN/RFP Comfort Control ValveTroubleshooting Local Path Trouble Shooting the GAS Control SystemCode # Part Description Replacement Parts ListIRFSDV24 IRFSDV34 Replacement Parts

IRFSDV24, IRFSDV34 specifications

The Vermont Casting IRFSDV34 and IRFSDV24 are two exceptional models in the line of high-quality gas fireplaces that blend efficiency, style, and advanced technology. Designed to provide warmth and comfort, these fireplaces are perfect for homeowners looking to enhance their living spaces with an attractive and functional heating solution.

Both models are designed for superior performance, featuring an efficient gas burner that ensures even heat distribution. The IRFSDV34 has a larger firebox compared to the IRFSDV24, making it an ideal choice for larger rooms, while the IRFSDV24 is perfect for smaller spaces. This versatility allows consumers to select the model that best fits their home layout and heating requirements.

One of the standout features of the Vermont Casting fireplaces is their realistic flame presentation. The advanced flame technology simulates the flickering glow of real wood, adding an inviting ambiance to any setting. The adjustable flame height also allows users to personalize the heat output and brightness, catering to both functional and aesthetic needs.

In terms of efficiency, both the IRFSDV34 and IRFSDV24 are engineered to achieve high efficiency ratings, ensuring that they provide significant heat while consuming less fuel. This makes them an environmentally friendly choice for heating, leading to potential savings on energy bills. The models are also equipped with an adjustable air shutter that allows for precise control over combustion, enhancing overall performance.

Safety is a crucial factor in any gas fireplace, and Vermont Castings have prioritized this in both models. Equipped with features like a safety shut-off system and tempered safety glass, these fireplaces ensure peace of mind while enjoying the warmth they provide. Additionally, both models are designed for ease of use, with an intuitive control panel that simplifies operation.

The aesthetics of the Vermont Casting IRFSDV34 and IRFSDV24 are equally impressive. Available in a variety of finishes, they can seamlessly integrate into different interior designs, making them a stylish addition to any home. The classic cast iron construction not only imparts a timeless look but also ensures durability and longevity.

Overall, the Vermont Casting IRFSDV34 and IRFSDV24 fireplaces encapsulate a perfect balance of technology, efficiency, and design, providing homeowners with an unparalleled heating experience. Whether seeking to create a cozy atmosphere or enhance the heating capabilities of their living space, these models stand out as premier choices in the market.