Vermont Casting IRFSDV34, IRFSDV24 Lighting and Operating Instructions, Lighting Instructions

Page 22

Irving Oil

LIGHTING AND OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A. This fireplace has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly.

B. BEFORE LIGHTING smell all around the fireplace area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this page.

2.Turn off all electrical power to the fireplace appliance. 3.For MN/MP/TN/TP appliances only, go on to

Step 4. for RN/RP turn the On/Off switch to “OFF” position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn

clockwise to “OFF”. Do not force.

 

 

 

ILO

OFF

 

 

 

P

T

PILOT

 

 

 

 

 

HI

F

 

 

ON

 

OFF

 

ON

 

F

 

LO

PILOT

O

 

FFO

 

 

 

 

 

 

 

 

 

 

EURO SIT

 

SIT NOVA

HONEYWELL

6.Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas , STOP! Follow “B” in the safety information above this page. If you don’t smell gas, go to the next step.

7.Remove window fram assembly glass door before lighting pilot. (See Glass Frame Removal in manual).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counter clockwise

to “PILOT”.

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2"

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to “OFF” and call your service technician or gas supplier.

11.Replace window fram assembly.

12.Turn gas control knob to “ON” position.

13.For RN/RP appliances turn the ON/OFF switch to “ON” position or set themostat to desired setting.

14.Turn on all electrial power to the fireplace.

TO TURN OFF GAS FIREPLACE

1.Turn the On/Off switch to “OFF” or set the thermostat to lowest setting.

2.Turn off all electric power to the fireplace if service is to be performed.

3.Open control access panel.

4.Push in gas control knob slightly and turn clockwise to “OFF”. Do not force.

5.Close control access panel.

22

10004000

Image 22
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Locating Your Fireplace Installation & Operating InstructionsClearance to Combustibles Fireplace Dimensions When purging the gas line, the front glass must be removed GAS SpecificationsGAS Line Installation GAS Inlet and Manifold PressuresInstallation of Remote Switch for RN/RP GAS Valve ON/OFF Switch or Millivolt ThermostatCanadian Installations US Installations General Venting INFORMATION-TERMINATION LocationTermination Clearances Canadian Installations USA Installations, Dimension a plus B must not be greater than 17’ 5.2m Vertical Sidewall InstallationsVertical Sidewall Applications Example a To USE the Vent GraphSidewall Venting Graph Example BVent Opening Combustible Wall Vent Pipe AssemblyStep Vent Opening Noncombustible WallBelow Grade Installations Always install horizontal venting on a level planeVertical THROUGH-THE-ROOF Applications MinimumTo Install Vertical Venting Proceed to plumb for additional openings throughCrimped END Venting Components Twist Lock Venting Components Operating Instructions General Glass Information Installation of Logs & Burner Lava Rock MaterialGlass Cleaning Window Frame RemovalCleaning Procedure Installation of Logs & BurnerMaintenance Flame & Temperature Adjustment RFN/RFPRN/RP Models Flame & Temperature AdjustmentFlame Characteristics IRFSDV24 IRFSDV34Optional Gold Trim KIT Remote ControlsInstallation Procedure Optional Frame Window Trim KitsLighting Instructions For Your Safety Read Before LightingLighting and Operating Instructions To Turn OFF GAS FireplaceOperating Instructions for RFN/RFP Comfort Control Valve OperationTroubleshooting Trouble Shooting the GAS Control System Local PathReplacement Parts List Code # Part DescriptionIRFSDV24 IRFSDV34 Replacement Parts

IRFSDV24, IRFSDV34 specifications

The Vermont Casting IRFSDV34 and IRFSDV24 are two exceptional models in the line of high-quality gas fireplaces that blend efficiency, style, and advanced technology. Designed to provide warmth and comfort, these fireplaces are perfect for homeowners looking to enhance their living spaces with an attractive and functional heating solution.

Both models are designed for superior performance, featuring an efficient gas burner that ensures even heat distribution. The IRFSDV34 has a larger firebox compared to the IRFSDV24, making it an ideal choice for larger rooms, while the IRFSDV24 is perfect for smaller spaces. This versatility allows consumers to select the model that best fits their home layout and heating requirements.

One of the standout features of the Vermont Casting fireplaces is their realistic flame presentation. The advanced flame technology simulates the flickering glow of real wood, adding an inviting ambiance to any setting. The adjustable flame height also allows users to personalize the heat output and brightness, catering to both functional and aesthetic needs.

In terms of efficiency, both the IRFSDV34 and IRFSDV24 are engineered to achieve high efficiency ratings, ensuring that they provide significant heat while consuming less fuel. This makes them an environmentally friendly choice for heating, leading to potential savings on energy bills. The models are also equipped with an adjustable air shutter that allows for precise control over combustion, enhancing overall performance.

Safety is a crucial factor in any gas fireplace, and Vermont Castings have prioritized this in both models. Equipped with features like a safety shut-off system and tempered safety glass, these fireplaces ensure peace of mind while enjoying the warmth they provide. Additionally, both models are designed for ease of use, with an intuitive control panel that simplifies operation.

The aesthetics of the Vermont Casting IRFSDV34 and IRFSDV24 are equally impressive. Available in a variety of finishes, they can seamlessly integrate into different interior designs, making them a stylish addition to any home. The classic cast iron construction not only imparts a timeless look but also ensures durability and longevity.

Overall, the Vermont Casting IRFSDV34 and IRFSDV24 fireplaces encapsulate a perfect balance of technology, efficiency, and design, providing homeowners with an unparalleled heating experience. Whether seeking to create a cozy atmosphere or enhance the heating capabilities of their living space, these models stand out as premier choices in the market.