For Built-In Installation

WARNING: A licensed elec- trician must connect the wiring harness to electrical supply fol- lowing all local codes. Electri- cian must provide a clamp on the box cover to secure the wir- ing. Wiring should be routed through the bushing in the hole on the outer casing of heater.

Follow instructions Removing Valve Cover Shield (page 11), then

1.Install a snap bushing found in hardware kit into one of the holes found on rear of valve cover shield. The other hole is for a strain relief clamp (not supplied) to secure incoming electrical supply.

2.Follow steps 2 through 6 in Installing Blower Assembly, pages 11 and 12. Also remove black wire from middle switch terminal 2.

3.Remove black plastic strain relief and power cord from switch plate. The power cord supplied will not be used in built-in installations. Pop in the plastic snap bushing found in hardware kit into the hole left by supply cord/strain relief.

4.A licensed electrician must follow the wiring diagram to connect incoming electrical supply to fan kit wiring har- ness (see Figure 20).

5.Plug power cord to the outlet receptacle (not provided) as shown in Figure 21. Wind the extra cable in power cord and and tie it up with the plastic wire strap (see Figure 21). Set the cable bundle between the burner bracket and outer casing, away from the burner.

6.Reinstall valve cover shield.

7.Test to make sure the blower is work- ing properly.

8.Reinstall upper louver assembly and hood if previously removed, (see Figure 16, page 11). Close lower louver door.

 

Fan Switch

 

 

 

 

 

 

 

(Auto/Off/On)

 

 

 

 

 

 

 

 

1 Auto

 

 

 

 

 

 

 

Off

2

 

 

 

 

 

 

 

 

 

 

 

3

Blue

 

Thermostat

 

 

 

On

 

 

 

Switch

 

 

 

 

 

 

(N.O.)

110/115

 

 

Red

 

 

 

 

Blue

V.A.C.

 

 

 

 

Blower

 

Black

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red

 

 

White

 

 

 

 

 

 

 

 

 

 

 

 

 

White

 

 

Green

 

 

 

 

 

 

Green

Figure 20 - Wiring Diagram For Blower Accessory Built-In Installation

Blower Bracket

Assembly

Screw

Switch

 

Wire

 

 

 

 

Harness

 

 

 

 

Power

 

 

 

 

Cord

Outlet

 

 

 

 

 

3

 

 

Receptacle

 

2

 

 

 

 

1

 

 

 

 

Blue

Red

 

 

 

 

 

 

 

Switch Plate

 

 

 

 

Plastic Wire

 

 

 

 

Strap

 

 

 

 

Valve

 

 

 

 

Cover

 

 

 

 

Shield

Box Cover

 

 

Wire

 

 

Clamp Connector

Harness

 

 

(not included)

 

Figure 21 - Installing Blower Bracket Assembly

Continued

107105

13

Image 13
Contents What to do if YOU Smell GAS Compact Heat MajicNatural GAS VENT-FREE Fireplace System Safety InformationLocal Codes Product FeaturesUnpacking Product IdentificationInstalling Log AssemblyAssembling Fireplace Assembling HoodProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating FireplaceRough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationRemoving Upper Louver Assembly Installing Blower Accessory GA3450TInstalling Blower Assembly Assembling Brass Trim Brass trim shipped with mantelInstall the switch plate on the valve Wiring Diagram For Blower Accessory Built-In Installation For Built-In InstallationExtension Cord Connecting to GAS SupplyAttaching Wood Base to Solid Floor Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Operating Fireplace For Your Safety Read Before LightingLighting Instructions Inspecting Burner Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceBurner Flame Pattern CabinetObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Replacement Parts SpecificationsService Hints Technical ServiceFMH26TN Illustrated Parts BreakdownDescription QTY Parts ListAccessories 107105 Warranty Information

FMH26TN specifications

The FMI FMH26TN is a cutting-edge heating and cooling solution that has garnered attention for its innovative design and advanced features. This model exemplifies the fusion of efficiency and functionality, aiming to provide optimal comfort for both residential and commercial spaces.

One of the standout characteristics of the FMI FMH26TN is its powerful heating performance. It utilizes a high-efficiency burner system that enables it to produce an impressive output of 26,000 BTUs, making it suitable for medium to large-sized rooms. The unit employs an advanced heat exchanger that maximizes heat transfer while minimizing gas consumption, aligning with modern energy efficiency standards.

In addition to its robust heating capabilities, the FMH26TN also integrates a variety of technological advancements. It features an electronic ignition system that guarantees reliable startup with minimal energy waste. Moreover, the unit comes equipped with a multi-speed blower motor that not only enhances airflow but also allows users to adjust the heating intensity according to their preferences. This flexibility is especially beneficial during the transitional seasons when heating needs can vary significantly.

Another key component of the FMI FMH26TN is its state-of-the-art control system. The model supports programmable thermostats, enabling a tailored heating schedule that can adapt to any lifestyle. Users can easily set timers and temperature preferences, ensuring maximum comfort while enhancing energy savings.

The design of the FMI FMH26TN is also a notable feature. It boasts a sleek and modern aesthetic that can blend seamlessly into various interior styles. The unit is constructed with high-quality materials that ensure durability, which is indispensable for long-term use. Additionally, it includes a minimalistic control panel, making it user-friendly and accessible for anyone to operate.

Safety is another paramount concern addressed by the FMH26TN. The unit includes features such as an automatic shut-off system in case of overheating, ensuring peace of mind for users.

In summary, the FMI FMH26TN stands out for its powerful heating output, energy efficiency, modern design, and user-friendly technology. With its combination of advanced features, this model is poised to meet the diverse heating needs of contemporary living spaces while emphasizing reliability and comfort.