14.Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and re- pair fireplace.

15.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

16.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

17.Provide adequate clearances around air openings.

PRODUCT

FEATURES

SAFETY PILOT

This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff sys- tem. The ODS/pilot is a required feature for vent-free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This sys- tem requires no matches, batteries, or other sources to light fireplace.

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPACKING

THERMOSTATIC HEAT

CONTROL

This fireplace has a thermostat sensing bulb and a control valve. The thermostat will automatically modulate the heat output to maintain a consistent room temperature. This results in greater fireplace comfort. This can also result in lower gas bill.

PRODUCT IDENTIFICATION

Fireplace

Cabinet

Screen

Logs

Control Knob

Ignitor Button

Figure 1 - Vent-Free Natural Gas Fireplace System

1.Remove log box and fireplace from carton. The hood is not attached. IMPORTANT: The fireplace hood is inside the cardboard protective end wrap on the left side of fireplace (as viewed from front). A decal is on the outside of the cardboard end wrap stat- ing hood is enclosed (see Figure 2).

2.Remove hood from cardboard protec- tive end wrap as shown in Figure 2.

3.Remove all protective packaging ap- plied to fireplace for shipment.

4.Make sure your fireplace includes one hardware packet.

5.Check fireplace for any shipping damage. If fireplace is damaged, promptly inform dealer where you bought fireplace.

Hood

IMPORTANT:

Enclosed

THIS PACKAGE CONTAINS A

FIREPLACE HOOD. UNWRAP

Decal

CARTON AND REMOVE HOOD

BEFORE DISCARDING

 

PROTECTIVE PACKAGING.

 

Cardboard

 

Protective

 

Fireplace

 

End Wrap

 

2

 

1

 

Hood

Figure 2 - Removing Fireplace Hood

107105

3

Image 3
Contents What to do if YOU Smell GAS Compact Heat MajicNatural GAS VENT-FREE Fireplace System Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingAssembling Hood AssemblyInstalling Log Assembling FireplaceConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Locating Fireplace InstallationInstallation Items Check GAS TypeRough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationAssembling Brass Trim Brass trim shipped with mantel Installing Blower Accessory GA3450TRemoving Upper Louver Assembly Installing Blower AssemblyInstall the switch plate on the valve Wiring Diagram For Blower Accessory Built-In Installation For Built-In InstallationConnecting to GAS Supply Extension CordAttaching Wood Base to Solid Floor Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Inspecting Burner Cabinet Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Flame PatternObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Technical Service SpecificationsReplacement Parts Service HintsFMH26TN Illustrated Parts BreakdownDescription QTY Parts ListAccessories 107105 Warranty Information

FMH26TN specifications

The FMI FMH26TN is a cutting-edge heating and cooling solution that has garnered attention for its innovative design and advanced features. This model exemplifies the fusion of efficiency and functionality, aiming to provide optimal comfort for both residential and commercial spaces.

One of the standout characteristics of the FMI FMH26TN is its powerful heating performance. It utilizes a high-efficiency burner system that enables it to produce an impressive output of 26,000 BTUs, making it suitable for medium to large-sized rooms. The unit employs an advanced heat exchanger that maximizes heat transfer while minimizing gas consumption, aligning with modern energy efficiency standards.

In addition to its robust heating capabilities, the FMH26TN also integrates a variety of technological advancements. It features an electronic ignition system that guarantees reliable startup with minimal energy waste. Moreover, the unit comes equipped with a multi-speed blower motor that not only enhances airflow but also allows users to adjust the heating intensity according to their preferences. This flexibility is especially beneficial during the transitional seasons when heating needs can vary significantly.

Another key component of the FMI FMH26TN is its state-of-the-art control system. The model supports programmable thermostats, enabling a tailored heating schedule that can adapt to any lifestyle. Users can easily set timers and temperature preferences, ensuring maximum comfort while enhancing energy savings.

The design of the FMI FMH26TN is also a notable feature. It boasts a sleek and modern aesthetic that can blend seamlessly into various interior styles. The unit is constructed with high-quality materials that ensure durability, which is indispensable for long-term use. Additionally, it includes a minimalistic control panel, making it user-friendly and accessible for anyone to operate.

Safety is another paramount concern addressed by the FMH26TN. The unit includes features such as an automatic shut-off system in case of overheating, ensuring peace of mind for users.

In summary, the FMI FMH26TN stands out for its powerful heating output, energy efficiency, modern design, and user-friendly technology. With its combination of advanced features, this model is poised to meet the diverse heating needs of contemporary living spaces while emphasizing reliability and comfort.