FMI FMH26TN Operating Fireplace, For Your Safety Read Before Lighting, Lighting Instructions

Page 17

OWNER’S MANUAL

OPERATING

FIREPLACE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con- trol which has been under water.

LIGHTING

INSTRUCTIONS

WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information, column 1.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, column 1. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise the PILOT position. Press in control knob for five (5) seconds (see Figure 28).

Ignitor Button

Control Knob

Note: You may be running this fire- place for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is at- tached to the front of burner. If needed, keep pressing ignitor but- ton until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 20 through 22. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 18.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise

to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

Thermocouple

Ignitor Electrode

 

 

Pilot Burner

Figure 28 - Control Knob In The OFF

Position

Figure 29 - Pilot

Continued

107105

17

Image 17
Contents What to do if YOU Smell GAS Compact Heat MajicNatural GAS VENT-FREE Fireplace System Safety InformationLocal Codes Product FeaturesUnpacking Product IdentificationInstalling Log AssemblyAssembling Fireplace Assembling HoodProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Items InstallationCheck GAS Type Locating FireplaceRough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationRemoving Upper Louver Assembly Installing Blower Accessory GA3450TInstalling Blower Assembly Assembling Brass Trim Brass trim shipped with mantelInstall the switch plate on the valve Wiring Diagram For Blower Accessory Built-In Installation For Built-In InstallationAttaching Wood Base to Solid Floor Connecting to GAS SupplyExtension Cord Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Inspecting Burner Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceBurner Flame Pattern CabinetObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Replacement Parts SpecificationsService Hints Technical ServiceFMH26TN Illustrated Parts BreakdownDescription QTY Parts ListAccessories 107105 Warranty Information

FMH26TN specifications

The FMI FMH26TN is a cutting-edge heating and cooling solution that has garnered attention for its innovative design and advanced features. This model exemplifies the fusion of efficiency and functionality, aiming to provide optimal comfort for both residential and commercial spaces.

One of the standout characteristics of the FMI FMH26TN is its powerful heating performance. It utilizes a high-efficiency burner system that enables it to produce an impressive output of 26,000 BTUs, making it suitable for medium to large-sized rooms. The unit employs an advanced heat exchanger that maximizes heat transfer while minimizing gas consumption, aligning with modern energy efficiency standards.

In addition to its robust heating capabilities, the FMH26TN also integrates a variety of technological advancements. It features an electronic ignition system that guarantees reliable startup with minimal energy waste. Moreover, the unit comes equipped with a multi-speed blower motor that not only enhances airflow but also allows users to adjust the heating intensity according to their preferences. This flexibility is especially beneficial during the transitional seasons when heating needs can vary significantly.

Another key component of the FMI FMH26TN is its state-of-the-art control system. The model supports programmable thermostats, enabling a tailored heating schedule that can adapt to any lifestyle. Users can easily set timers and temperature preferences, ensuring maximum comfort while enhancing energy savings.

The design of the FMI FMH26TN is also a notable feature. It boasts a sleek and modern aesthetic that can blend seamlessly into various interior styles. The unit is constructed with high-quality materials that ensure durability, which is indispensable for long-term use. Additionally, it includes a minimalistic control panel, making it user-friendly and accessible for anyone to operate.

Safety is another paramount concern addressed by the FMH26TN. The unit includes features such as an automatic shut-off system in case of overheating, ensuring peace of mind for users.

In summary, the FMI FMH26TN stands out for its powerful heating output, energy efficiency, modern design, and user-friendly technology. With its combination of advanced features, this model is poised to meet the diverse heating needs of contemporary living spaces while emphasizing reliability and comfort.