FMI FMH26TN Connecting Equipment Shutoff Valve to Heater Control, Installation Items Needed

Page 15

OWNER’S MANUAL

INSTALLATION

Continued

CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROL

Installation Items Needed

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

4.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line/equipment shutoff valve (see Figure 25).

5.Check all gas connections for leaks. See Checking Gas Connections, page 16.

6.Replace branch support back into fire- place. Feed flexible gas line into fire- place base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reat- tach branch support to fireplace with screws removed in step 2.

1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

2.Remove screws that attach branch sup- port to fireplace (see Figure 24). Care- fully lift up branch support and remove from fireplace (see Figure 24).

3.Route flexible gas line, included, from fireplace control to equipment shutoff valve through side or rear access holes in outer casing.

NOTICE: Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 25).

BranchScreen

SupportShipping

Screw

Shoulder

Screw

Flexible

Gas Line

Screen

Figure 24 - Removing Branch Support From Fireplace

The flexible gas supply line con- nection to the equipment shutoff valve should be accessible.

To Fireplace

Gas Regulator

Flexible Gas Line from Fireplace Gas Regulator

Equipment Shutoff Valve Provided by Installer

To External

 

 

Regulator

Figure 25 - Attaching Flexible Gas Line to Equipment Shutoff Valve

Continued

107105

15

Image 15
Contents What to do if YOU Smell GAS Compact Heat MajicNatural GAS VENT-FREE Fireplace System Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingAssembling Hood AssemblyInstalling Log Assembling FireplaceConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Locating Fireplace InstallationInstallation Items Check GAS TypeRough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationAssembling Brass Trim Brass trim shipped with mantel Installing Blower Accessory GA3450TRemoving Upper Louver Assembly Installing Blower AssemblyInstall the switch plate on the valve Wiring Diagram For Blower Accessory Built-In Installation For Built-In InstallationConnecting to GAS Supply Extension CordAttaching Wood Base to Solid Floor Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Inspecting Burner Cabinet Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Flame PatternObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Technical Service SpecificationsReplacement Parts Service HintsFMH26TN Illustrated Parts BreakdownDescription QTY Parts ListAccessories 107105 Warranty Information

FMH26TN specifications

The FMI FMH26TN is a cutting-edge heating and cooling solution that has garnered attention for its innovative design and advanced features. This model exemplifies the fusion of efficiency and functionality, aiming to provide optimal comfort for both residential and commercial spaces.

One of the standout characteristics of the FMI FMH26TN is its powerful heating performance. It utilizes a high-efficiency burner system that enables it to produce an impressive output of 26,000 BTUs, making it suitable for medium to large-sized rooms. The unit employs an advanced heat exchanger that maximizes heat transfer while minimizing gas consumption, aligning with modern energy efficiency standards.

In addition to its robust heating capabilities, the FMH26TN also integrates a variety of technological advancements. It features an electronic ignition system that guarantees reliable startup with minimal energy waste. Moreover, the unit comes equipped with a multi-speed blower motor that not only enhances airflow but also allows users to adjust the heating intensity according to their preferences. This flexibility is especially beneficial during the transitional seasons when heating needs can vary significantly.

Another key component of the FMI FMH26TN is its state-of-the-art control system. The model supports programmable thermostats, enabling a tailored heating schedule that can adapt to any lifestyle. Users can easily set timers and temperature preferences, ensuring maximum comfort while enhancing energy savings.

The design of the FMI FMH26TN is also a notable feature. It boasts a sleek and modern aesthetic that can blend seamlessly into various interior styles. The unit is constructed with high-quality materials that ensure durability, which is indispensable for long-term use. Additionally, it includes a minimalistic control panel, making it user-friendly and accessible for anyone to operate.

Safety is another paramount concern addressed by the FMH26TN. The unit includes features such as an automatic shut-off system in case of overheating, ensuring peace of mind for users.

In summary, the FMI FMH26TN stands out for its powerful heating output, energy efficiency, modern design, and user-friendly technology. With its combination of advanced features, this model is poised to meet the diverse heating needs of contemporary living spaces while emphasizing reliability and comfort.