Vermont Casting CR36L, CR36R manual Chimney Requirements Offset Installations, Illustration Key

Page 5

CR Series Woodburning Fireplaces

Chimney Requirements - Offset Installations

Chimney Flue Exit

 

 

Chimney

 

 

 

 

Section

 

 

 

 

Elbow

 

30°

 

 

 

 

Return

A

 

B

G

Elbow

 

 

 

 

 

 

 

 

30°

G

D

 

 

Offset

 

E

Rise

Elbow

 

 

 

 

C

6 FT.

 

30°

SKCS8

 

 

 

 

Support

 

 

Return

 

 

H

 

 

Offset

Elbow

 

 

 

 

H

 

 

 

30°

B

 

 

 

 

 

Offset

 

 

 

 

Elbow

 

 

Hearth Floor

 

 

Example 1

 

Example 2

 

Example 3

NOTE: G + H Cannot Exceed 20’

 

 

FP269CR

OFFSET

RISE

 

 

 

 

 

 

 

FP282

 

 

 

 

 

 

30˚ Elbow Offsets

 

 

 

 

 

 

 

 

 

 

 

1’

1¹⁄₂' 3’

4’

Chimney Support

Offset

Rise

 

 

 

 

 

 

 

 

 

 

0

0

0

0

0

3”

11”

 

 

1

0

0

0

0

8¹⁄"

20"

 

 

0

1

0

0

0

11¹⁄" 25¹⁄"

 

 

2

0

0

0

0

13¹⁄" 29¹⁄"

 

 

1

1

0

0

0

16¹⁄" 34¹⁄"

 

 

0

0

1

0

0

20¹⁄" 40³⁄"

 

 

2

1

0

0

0

21³⁄" 43¹⁄"

 

 

0

0

0

1

0

26¹⁄" 51¹⁄"

 

 

0

1

1

0

0

28¹⁄" 55¹⁄"

 

 

1

0

0

1

0

31¹⁄" 60¹⁄

 

 

0

1

0

1

0

34¹⁄" 65¹⁄"

 

 

0

0

2

0

0

37¹⁄" 70³⁄"

 

 

1

1

0

1

1

41¹⁄" 77³⁄"

 

 

0

0

1

1

1

45" 83³⁄"

 

 

0

1

2

0

1

47¹⁄" 87¹⁄"

 

 

0

0

0

2

1

51"

94"

 

Illustration Key

The following safety rules apply to offset installations. (The letters correspond with letters above):

A.Height of the chimney measured from the hearth to the chimney exit at top:

 

CR36L/R Series

Maximum:

90’0”

Minimum:

 

Without elbows

14’ 0”

With 2 elbows

15’ 0”

With 4 elbows

21’ 0”

B.Do not use more than four elbows per chimney.

Attach the straps of the top elbows to a structural framing member.

The first elbow of any pair does not have straps.

C.The chimney cannot be more than 30° from the vertical plane.

D.The maximum length of the angled run of the total chimney system is 20 feet. (G plus H cannot exceed 20 feet)

E.A chimney support (Model SKCS8) is required every 6 feet of angled run of chimney. Chimney supports are required at 30 feet and 60 feet of chimney height above the hearth also.

Determine the offset distance of your chim- ney arrangement from the centerline of the fireplace to the centerline of the chimney where it is to pass through the first ceiling.

NOTE: This offset distance may not be your full offset distance. See Examples 2 and 3.

0

1

1

1

1

53¹⁄"

98"

0

0

3

0

1

56¹⁄" 103¹⁄"

0

1

0

2

1

59¹⁄" 108¹⁄"

0

0

2

1

1

62¹⁄" 113¹⁄"

0

1

3

0

1

64¹⁄" 117¹⁄"

0

0

1

2

1

68¹⁄"

124"

0

1

2

1

1

70¹⁄"

128"

0

0

0

3

1

74¹⁄" 134¹⁄"

0

1

1

2

2

78" 140³⁄"

0

0

3

1

2

81"

146"

0

1

0

3

2

84" 151¹⁄"

0

0

2

2

2

87" 156¹⁄"

0

1

3

1

2

89¹⁄" 160¹⁄"

0

0

1

3

2

93" 166³⁄"

0

1

2

2

2

95¹⁄" 170³⁄"

0

0

0

4

2

99¹⁄" 177³⁄"

0

1

1

3

2

101¹⁄" 181³⁄"

0

0

3

2

2

104¹⁄" 186¹⁄"

0

1

0

4

2

107¹⁄" 191¹⁄"

0

0

2

3

2

110¹⁄" 196³⁄"

0

1

3

2

3

114" 203¹⁄"

0

0

1

4

3

117³⁄" 209³⁄"

0

1

2

3

3

120" 213¹⁄"

0

0

0

5

3

123³⁄"

220"

Fig. 3 Chimney system requirements.

20001316

5

Image 5
Contents CR Series Table of Contents Safety InformationCR36R/L Series Woodburning Fireplace Chase Installation Illustration Key Chimney Requirements Offset InstallationsMounting the Fireplace Planning InformationPlanning the Chimney Run Ten Foot RuleInsulating Fireplace Enclosure For Cold Climates InstallationChase Installation Offset Installation Straight-Up Chimney InstallationFraming Chimney Set-upCeiling Chimney Hole Possible Obstructions Positioning, Safety Strips Securing the FireplaceCutting the Hole Framing the Ceiling HolePipe section is mounted Installing the Chimney SystemInstalling the Firestop Spacer Ceiling Hole Canadian Requirements for Insulation Shield Proper Firestop Spacer InstallationAdditional Ceilings Penetrating the RoofInstalling Top Housing or Termination Install Remainder of Chimney SectionsInstalling Chimney In a Chase Cut and Frame Roof HoleTop View CR Series Woodburning FireplacesSide Wall Protection Hearth InstallationFinish Wall Minimum Wall Clearances Minimum Hearth Extension DimensionsInstalling Line for Gas Logs Item/Model Number CR36R/L Woodburning FireplaceAccessory Description Model No Accessories36GCKBB AK-MSTS20BR/BT/BW SKCS8SLTSK8 PLTSK8RLTSK8L RLTSK8Accessory Description CR Series Woodburning Fireplaces Liners Refractory or Metal Firegrate, Glass Doors, Outside Air SystemFan Motor CFM Corporation