CR Series Woodburning Fireplaces

Installing Line for Gas Logs

Majestic Fireplaces CR36R/L Series fireplace is de- signed to accept a 1/2” gas line for an approved gas appliance. (CFM Corporation manufactures a wide variety of gas logs for use in Majestic Fireplaces.) Have the appliance installed by a qualified plumber in accordance with all building codes. The gas connec- tion enters the fireplace at the end opposite the open end.

Locate the gas line hole in the outer casing of the fireplace and remove the insulation from the gas line tube. (Fig. 24)

Ceramic or Metal

Knockout

Hole in

Outer

Casing

From inside the fireplace, locate the knockout on the firebrick. Using a flat bladed screwdriver or small chisel and hammer, carefully tap around the knockout until it loosens and falls out.

Now, install 1/2” certified gas pipe through the open- ing. After the gas pipe installation is complete, use the insulation that was removed from the gas line tube

Hole in Outer

 

1"

 

 

1”

Casing

Gas

Min.

 

Line

 

 

Tube

 

 

Ceramic

 

 

or Metal

 

 

Knockout

 

Supply Line

Repack Insulation

1/2"

FP560CR

to repack the space around the pipe. This should be inserted from the outside of the fireplace and packed tightly to totally seal between the pipe and the tube.

NOTE: The gas pipe should not come in contact with any wood structures until it has reached a point at least one (1) inch away from the fireplace side.

NOTE: Local codes may require removal of flue damper when installing any type of gas appliance in a fireplace.

The gas pipe installation is intended for connection to a decorative gas appliance only (1) incorporating an automatic shutoff device and (2) complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces, ANSI Z21.60 or CSA draft re- quirements for Gas-Fired Log Lighters for Woodburn- ing Fireplaces (Draft No. 4, August 1993).

The decorative gas appliance should be installed in accordance with the National Fuel Gas Code, ANSI Z223.1-1988.

Fig. 24 Install iron pipe gas line through hole provided in angled side of fireplace.

CAUTION: WHEN USING DECORATIVE GAS AP- PLIANCE, THE FLUE DAMPER MUST BE SET IN THE FULLY OPEN POSITION. IF YOU HAVE GLASS DOORS ON THE FIREPLACE, THEY MUST ALSO BE FULLY OPENED.

16

20001316

Image 16
Contents CR Series Safety Information Table of ContentsCR36R/L Series Woodburning Fireplace Chase Installation Chimney Requirements Offset Installations Illustration KeyPlanning Information Mounting the FireplacePlanning the Chimney Run Ten Foot RuleChase Installation InstallationInsulating Fireplace Enclosure For Cold Climates Straight-Up Chimney Installation Offset InstallationFraming Chimney Set-upPositioning, Safety Strips Securing the Fireplace Ceiling Chimney Hole Possible ObstructionsCutting the Hole Framing the Ceiling HoleInstalling the Firestop Spacer Ceiling Hole Installing the Chimney SystemPipe section is mounted Proper Firestop Spacer Installation Canadian Requirements for Insulation ShieldAdditional Ceilings Penetrating the RoofInstall Remainder of Chimney Sections Installing Top Housing or TerminationInstalling Chimney In a Chase Cut and Frame Roof HoleCR Series Woodburning Fireplaces Top ViewFinish Wall Hearth InstallationSide Wall Protection Minimum Hearth Extension Dimensions Minimum Wall ClearancesInstalling Line for Gas Logs CR36R/L Woodburning Fireplace Item/Model NumberAccessories Accessory Description Model No36GCKBB AK-MSTSKCS8 S20BR/BT/BWSLTSK8 PLTSK8RLTSK8 RLTSK8LAccessory Description CR Series Woodburning Fireplaces Fan Motor Firegrate, Glass Doors, Outside Air SystemLiners Refractory or Metal CFM Corporation