Empire Comfort Systems VFD36FB2DL-1, VFD32FB2DL-1 See , Connection a, See , Connection B

Page 13

4.Insert blower assembly into interior, bottom of firebox. Posi- tion blower assembly so that you align the notch on back of blower assembly with the center screw on firebox back, then push the blower assembly against firebox back. The blower wheel must be centered with the back wall of the firebox. The magnets on the back and bottom of blower assembly will suf- ficiently hold blower assembly in place.

Note: For field installation of blower assembly, it may be easier to remove rear cover panel to install blower. This eliminates the need to remove brick liner panels, but the blower would have to be installed prior to installing the firebox into a wall or chase. See Figure 28.

REAR COVER PANEL MAY BE

REMOVED TO INSTALL BLOWER

REINSTALL COVER AFTER

BLOWER IS INSTALLED

Figure 28

5.Once the blower assembly is in position, locate the plug but- ton in the top right rear corner of the firebox. Remove the plug with a standard screwdriver and discard plug.

6.Next, find the fan control switch and wire assembly. Feed the wires through the hole at the top of the firebox, and secure the fan control switch with (2) #6 screws provided. See Figure 29.

8.One fan control wire will have a 1/4” female terminal that must be attached to the open terminal on the blower motor.

See Figure 32, Connection A.

9.The other fan control wire has a 1/4” male terminal. Attach this terminal to the open terminal on the blower power cord.

See Figure 32, Connection B

10.Route the wires away from moving parts of the blower as- sembly and retain wires together near the blower motor using the plastic purse clip provided.

11.To complete the installation, plug the power cord into the junction box receptacle at the right rear corner of the firebox outer wrap. See Figure 30.

12.If room permits, the power cord can be located from the out- side of the unit looking through the junction box access hole (with the junction box removed), then plug up the power cord before reinstalling the pre-wired junction box.

13.Once all connections are made electrically, it is recommend- ed that you test the blower fan control operation by turning on power to the blower (Caution: 110 Volt). Then apply heat to the fan control switch inside the firebox with a lighter or match until blower is activated. Once blower is activated, check for proper operation. Do not place hands near blower assembly or other wiring while power is on.

14.Replace blower access plate and/or reinstall the brick liner panels if provided.

15.This completes the installation of the optional FBB5 Blower kit accessory.

Note: This blower is equipped with a heat activated fan control switch. Blower will operate when the firebox warms up, and will turn off automatically when the firebox cools down.

 

BLOWER POWER CORD

FAN CONTROL

Figure 30

SWITCH LOCATION

FAN CONTROL WIRES

Figure 29

7.The fan control wires will slide down between the firebox and outer wrap near the blower assembly. See Figure 29.

23200-0-1206

Page 13

Image 13
Contents Effective Date December Installation InstructionsTable of Contents Instructions to Installer Important Safety InformationQualified Installing Agency IntroductionClearances Firebox Installation InstructionsClearances to combustibles Gas shut off must be in this lineDeluxe Vent-Free Firebox Framing Dimensions in inches Planning Your InstallationFirebox Framing Firebox Installation Instructions Installing Hood Extended Hoods GAS Line ConnectionFinishing Sharp edges Standard ScrewdriverFresh AIR KIT Parts List Index Quantity Description Supplied Completion of Air Kit installation Wiring Optional Single Speed Blower Installation InstructionsSee , Connection B See , Connection aBlower Wheels Blower MotorMaintenance Junction BOX Wiring Installation InstructionsParts List HOW to Order Repair Parts Parts View Variable Speed Control Kit AccessoriesBrick Liners Fresh Air KitLouvers Extended 4 HoodsBottom Trim Strip Decorative Door Kits